This study compares the shear bond strengths of plastic brackets with a mechanical base and metal brackets using two different adhesives, and examines the modes of failure using a scanning electron microscope (SEM). Forty extracted human premolars were selected for bonding. Two types of brackets: metal and plastic-Spirit MB, and two orthodontic adhesives: System 1+ and Enlight, were used. After bonding, all samples were put into a 37°C distilled water bath for 24 hours before shear bond strengths were tested. The bond strengths of the plastic brackets were significantly lower than those of the metal brackets (P < .0001). There was a statistically significant difference in bond strengths between System 1+ and Enlight for plastic brackets (P < .05), but not for metal brackets. The modes of failure predominantly occurred at the enamel/adhesive interface in the metal bracket-System 1+ group, within the adhesive in the metal bracket-Enlight and plastic bracket-System 1+ groups, and at the bracket/adhesive interface in the plastic bracket-Enlight group.

Esthetic orthodontic appliances have been in demand for adult patients in recent years.1 Plastic brackets made of polycarbonate and plastic molding powder were first introduced by Newman.2,3 The use of plastic brackets was limited because of their poor physical properties, resulting in problems such as fracture, stain, and distortion of the brackets. Lower bond strengths were also noted.4,5 To correct these problems, a new generation of plastic bracket with a metal slot and a mechanical base was recently introduced. Studies showed that the torque-deformation characteristics were not clinically significant for the metal slot reinforced brackets,6,7 but the bond strengths of the new plastic brackets varied.8–11 The objectives of this study are (1) to compare shear bond strengths of plastic brackets with a mechanical base to metal brackets using two different adhesives, and (2) to examine modes of failure after debonding using scanning electron microscope (SEM).

Human premolars were extracted for orthodontic reasons and stored at room temperature in water. The water in which the teeth were stored was changed every day before bonding. Forty premolars were selected for bonding.

Two types of brackets, metal and plastic-Spirit MB, and two orthodontic adhesives, System 1+ and Enlight, were used. All materials were products of Ormco Co (Glendale, Calif, USA). Both types of brackets were those used for premolars in the standard edgewise technique. The metal bracket has a mesh base. The Spirit MB is a polycarbonate bracket with a metal slot and a mechanical base. The bracket base area was estimated by weighing a uniform lead foil that was applied to cover precisely the base surface of one bracket, with three measurements for each type of bracket. The average bracket base area was 9.73 mm2 and 11.07 mm2 for the metal and plastic brackets, respectively. System 1+ is a urethane-modified dimethacrylate resin (UDM) and a no-mix chemical curing orthodontic adhesive. Enlight is a Bis-GMA resin and a 1-paste, fluoride-releasing, light-cure adhesive.

After the premolars were polished, cleaned, and air-dried, the brackets were bonded to the teeth with adhesives according to the manufacturer's instructions. The samples were divided into four groups with different combinations of brackets and adhesives. A 0.017 inch × 0.025 inch stainless steel sectional wire was put into the slot as a guide and tied by a ligature wire to the wings. The wire was placed immediately for the Enlight groups and five minutes after bonding for the System 1+ groups. Then, the teeth with the guides were embedded in die stone. All samples were put into a 37°C distilled water bath for 24 hours before the shear bond strengths were tested. A universal testing machine (AG-2000E, Shimadzu, Kyoto, Japan) was used to test the shear bond strengths of the four groups at a crosshead speed of 0.5 mm/minute. The results of the shear bond strengths of the four groups were compared by unpaired t-tests.

After the shear bond strengths were tested, the tooth surfaces were observed with a scanning electron microscope (Hitachi S-5000, Hitachi, Mito City, Japan) to evaluate the mode of failure at 25× magnification and enamel fracture at 150× magnification. Adhesive remnant index (ARI) scores12 were recorded for each specimen to represent the mode of failure. A score of zero indicates no adhesive left on the tooth, one indicates less than half of the adhesive left on the tooth, two indicates more than half of the adhesive left on the tooth, and three indicates all the adhesive left on the tooth. The results of the ARI scores of four groups were compared by Wilcoxon Signed Rank test.

The shear bond strengths of the various combinations of brackets and orthodontic adhesives are shown in Table 1. The bond strengths of the plastic brackets were significantly lower than those of the metal brackets for both adhesives (P < .0001). There was a statistically significant difference in bond strengths between System 1+ and Enlight for plastic brackets (P < .05), but not for metal brackets.

TABLE 1.

Shear Bond Strengths (MPa) of Various Combinations of Brackets and Adhesivesa

Shear Bond Strengths (MPa) of Various Combinations of Brackets and Adhesivesa
Shear Bond Strengths (MPa) of Various Combinations of Brackets and Adhesivesa

The ARI scores and number of enamel fractures are shown in Table 2. An ARI score of one was predominantly present in the metal bracket-System 1+ group, two in the metal bracket-Enlight and plastic bracket-System 1+ groups, and three in the plastic bracket-Enlight group (P < .05). There were five enamel fractures in the metal bracket-System 1+ group and none in the plastic bracket-Enlight group. An SEM at 25× magnification of the surface of one tooth in each group is shown in Figures 1 to 4.

TABLE 2.

ARI Scores and Number of Enamel Fractures for Various Combinations of Brackets and Adhesivesa

ARI Scores and Number of Enamel Fractures for Various Combinations of Brackets and Adhesivesa
ARI Scores and Number of Enamel Fractures for Various Combinations of Brackets and Adhesivesa
FIGURE 1.

SEM (25×) shows the enamel surface after debonding in metal bracket—System 1+ group. ARI score = 1. Enamel fracture is noted

FIGURE 1.

SEM (25×) shows the enamel surface after debonding in metal bracket—System 1+ group. ARI score = 1. Enamel fracture is noted

Close modal

The bond strengths of plastic brackets ranged from 1.4 MPa to 19.07 MPa. The differences are due to different combinations of bracket and adhesive.8–11,13–17 In most studies, the bond strengths of plastic brackets were significantly lower than those of metal brackets.8–11,13–16 The bond strength of Spirit MB ranged from 1.4 MPa to 10.3 Mpa, with most values in the 3 to 6 MPa range.8–11 In our study, the mean bond strengths of Spirit MB were 4.4 MPa and 6.3 MPa for System 1+ and Enlight, respectively, which showed a statistically significant difference. Most Bis-GMA adhesives provide enough bond strength for plastic brackets,8–11,13 whereas glass ionomer cement does not.8 System 1+ provided enough bond strength in one study,16 but not in another.11 Reynolds stated that a minimum bond strength of 5.9 to 7.9 MPa results in successful clinical bonding.18 In this study, Spirit MB-Enlight group could provide successful clinical bonding.

Figure 5 illustrates the load-displacements of the four groups during debonding. Because of creep with the plastic brackets, their load-displacements sloped down slowly after the maximum load while those of the metal brackets sloped straight down. Creeping of the plastic brackets could be noted in this study, but metal slot reinforced plastic brackets were clinically capable of torquing teeth sufficiently in two other studies.6,7 

FIGURE 5.

The load-displacements of the four groups when debonding. E indicates Enlight; S, System 1+; M, metal; P, plastic; and N, Newton

FIGURE 5.

The load-displacements of the four groups when debonding. E indicates Enlight; S, System 1+; M, metal; P, plastic; and N, Newton

Close modal

The average ARI scores of the metal brackets were lower than those of the plastic brackets for both adhesive groups. The lower ARI scores of the metal brackets may be due to their higher bond strengths. Lower ARI scores mean that the mode of failure is closer to the enamel/adhesive interface and the risk of enamel fracture increases. There were more enamel fractures in the metal groups than in the plastic groups in this study.

Although there was no significant difference in bond strength between the two adhesives in the metal bracket groups, there were five enamel fractures in the System 1+ group and two in the Enlight group. These adhesives have the same difunctional monomer and they are extremely viscous. For practical reasons, they are diluted with another difunctional monomer of much lower viscosity.19 In clinical use, System 1+ has a higher stickiness than Enlight. The higher stickiness may be the reason for the higher number of enamel fractures. Clinicians should choose suitable adhesives with high bond strengths and a mode of failure close to the bracket/adhesive interface for different types of brackets.

The shear bond strengths of plastic brackets were significantly lower than those of metal brackets (P < .0001). There was a statistically significant difference in bond strengths between System 1+ and Enlight for plastic brackets (P < .05), but not for metal brackets. The modes of failure were predominantly in the enamel/adhesive interface in metal bracket-System 1+ group, within adhesive in the metal bracket-Enlight and plastic bracket-System 1+ groups, and in the bracket/adhesive interface in the plastic bracket-Enlight group.

FIGURE 2.

SEM (25×) shows the enamel surface after debonding in plastic bracket—System 1+ group. ARI score = 2. Enamel fracture is noted

FIGURE 2.

SEM (25×) shows the enamel surface after debonding in plastic bracket—System 1+ group. ARI score = 2. Enamel fracture is noted

Close modal
FIGURE 3.

SEM (25×) shows the enamel surface after debonding in metal bracket—Enlight group. ARI score = 2. No enamel fracture is seen

FIGURE 3.

SEM (25×) shows the enamel surface after debonding in metal bracket—Enlight group. ARI score = 2. No enamel fracture is seen

Close modal
FIGURE 4.

SEM (25×) shows the enamel surface after debonding in plastic bracket—Enlight group. ARI score = 3. No enamel fracture is seen

FIGURE 4.

SEM (25×) shows the enamel surface after debonding in plastic bracket—Enlight group. ARI score = 3. No enamel fracture is seen

Close modal

The authors thank Professor Ruey-Mo Lin, Professor Chun-Pin Lin, and Assistant Professor Kuan-Zong Fung for providing facilities and technical help. This study was supported by grant NCKUH-89–084 from National Cheng Kung University Hospital, Tainan, Taiwan.

1
Sinha
,
P. K.
and
R. S.
Nanda
.
Esthetic orthodontic appliances and bonding concerns for adults.
Dent Clin North Am
1997
.
41
:
89
109
.
2
Newman
,
G. V.
Adhesion and orthodontic plastic attachments.
Am J Orthod
1969
.
56
:
573
588
.
3
Newman
,
G. V.
First direct bonding in orthodontia.
Am J Orthod Dentofacial Orthop
1992
.
101
:
190
191
.
4
Aird
,
J. C.
and
P.
Durning
.
Fracture of polycarbonate edgewise brackets: a clinical and SEM study.
Br J Orthod
1987
.
14
:
191
195
.
5
Dobrin
,
R. J.
,
I. L.
Kamel
, and
D. R.
Musich
.
Load-deformation characteristics of polycarbonate orthodontic brackets.
Am J Orthod
1975
.
67
:
24
33
.
6
Feldner
,
J. C.
,
N. K.
Sarkar
,
J. J.
Sheridan
, and
D. M.
Lancaster
.
In vitro torque-deformation characteristics of orthodontic polycarbonate brackets.
Am J Orthod Dentofacial Orthop
1994
.
106
:
265
272
.
7
Alkire
,
R. G.
,
M. D.
Bagby
,
M. A.
Gladwin
, and
H.
Kim
.
Torsional creep of polycarbonate orthodontic brackets.
Dent Mater
1997
.
13
:
2
6
.
8
Blalock
,
K. A.
and
J. M.
Powers
.
Retention capacity of the bracket bases of new esthetic orthodontic brackets.
Am J Orthod Dentofacial Orthop
1995
.
107
:
596
603
.
9
Fernandez
,
L.
and
J. A.
Canut
.
In vitro comparison of the retention capacity of new aesthetic brackets.
Eur J Orthod
1999
.
21
:
71
77
.
10
Urabe
,
H.
,
P. E.
Rossouw
,
K. C.
Titley
, and
C.
Yamin
.
Combinations of etchants, composite resins, and bracket systems: an important choice in orthodontic bonding procedures.
Angle Orthod
1999
.
69
:
267
275
.
11
Guan
,
G.
,
T.
Takano-Yamamoto
,
M.
Miyamoto
,
T.
Hattori
,
K.
Ishikawa
, and
K.
Suzuki
.
Shear bond strengths of orthodontic plastic brackets.
Am J Orthod Dentofacial Orthop
2000
.
117
:
438
443
.
12
Årtun
,
J.
and
S.
Bergland
.
Clinical trails with crystal growth conditioning as an alternative to acid-etch pretreatment.
Am J Orthod
1984
.
85
:
333
340
.
13
Harria
,
A. M.
,
V. P.
Joseph
, and
P. E.
Rossouw
.
Shear peel bond strengths of esthetic orthodontic brackets.
Am J Orthod Dentofacial Orthop
1992
.
102
:
215
219
.
14
Willems
,
G.
,
C. E. L.
Carels
, and
G.
Verbeke
.
In vitro peel/shear bond strength evaluation of orthodontic bracket base design.
J Dent
1997
.
25
:
271
278
.
15
Akin-Nergiz
,
N.
,
I.
Nergiz
,
K.
Behlfelt
, and
U.
Platzer
.
Shear bond strength of a new polycarbonate bracket—an in vitro study with 14 adhesives.
Eur J Orthod
1996
.
18
:
295
301
.
16
Nkenke
,
E.
,
U.
Hirschfelder
,
P.
Martus
, and
H.
Eberhard
.
Evaluation of the bond strength of different bracket-bonding systems to bovine enamel.
Eur J Orthod
1997
.
19
:
259
270
.
17
Reynolds
,
I. R.
and
J. A.
von Fraunhofer
.
Direct bonding in orthodontics: a comparison of attachments.
Br J Orthod
1977
.
4
:
65
69
.
18
Reynolds
,
I. R.
A review of direct orthodontic bonding.
Br J Orthod
1975
.
2
:
171
178
.
19
Sturdevant
,
C. M.
,
T. M.
Roberson
,
H. O.
Heymann
, and
J. R.
Sturdevant
.
The Art and Science of Operative Dentistry. 3rd ed.
St Louis, Mo: Mosby-Year Book Inc; 1994:206–287
.

Author notes

Corresponding author: Dr Jia-Kuang Liu, Department of Dentistry, National Cheng Kung University Hospital, 138 Sheng-Li Road, Tainan 704, Taiwan, ROC ([email protected])