Magnesium (Mg) and its alloys undergo corrosion at high rates in aqueous electrolytes of essentially any concentration, releasing copious amounts of hydrogen (H2) into the electrolyte, thereby making conventional scanning electrochemical microscopy (SECM) measurements difficult upon Mg. Examples of the issues associated with Mg SECM, and strategies to counter these, are discussed in this review. SECM has been employed in Sample Generation-Tip Collection (SG-TC) mode to image cathodic sites on the Mg surface, wherein, the platinum (Pt) tip oxidizes H2 emanating from the specimen surface. This mode of SECM does not clearly reveal a close correspondence between the microstructure and its associated reactivity; the H2 currents measured by the Pt tip found to vary by over an order of magnitude with time. Convective fluxes due to H2 bubbles, local acidification from protons released during H oxidation on the Pt tip, and the negative difference effect of Mg may contribute to these high tip currents. SECM has also been performed on Mg using Mg2+ ion selective electrodes (ISEs), where an Mg2+ ionophore cocktail serves as a Mg2+ ion permeable membrane. The Mg2+ ions diffuse/migrate through the membrane which eventually settles at the equilibrium membrane potential (Donnan potential). This potential varies with the logarithm of Mg2+ ion concentration in the electrolyte, and thus, could be used to ascertain the local Mg2+ ion concentrations (or anodic sites) on the surface. This technique needs to be complemented with other modes of SECM to obtain holistic electrochemical micrographs of a corroding Mg surface.
Skip Nav Destination
Article navigation
1 February 2015
CORROSION AND PROTECTION OF MAGNESIUM AND MAGNESIUM ALLOYS|
November 21 2014
Possibilities and Limitations of Scanning Electrochemical Microscopy of Mg and Mg Alloys
R.M. Souto
‡Corresponding author. E-mail: [email protected].
Search for other works by this author on:
CORROSION (2015) 71 (2): 171–183.
Article history
Received:
September 12 2014
Revision Received:
November 18 2014
Accepted:
November 18 2014
Citation
S. Thomas, J. Izquierdo, N. Birbilis, R.M. Souto; Possibilities and Limitations of Scanning Electrochemical Microscopy of Mg and Mg Alloys. CORROSION 1 February 2015; 71 (2): 171–183. doi: https://doi.org/10.5006/1483
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your InstitutionCiting articles via
Identification of Synergistic Interactions in Green Corrosion Inhibitor Mixtures by Molecular Modeling
Carlos M. Menendez, Oleg A. Mazyar, Sunder Ramachandran, Tracey Jackson
Resistance of the welded joint of X70 steel for main gas pipelines against corrosion-mechanical cracking under cathodic polarization in near-neutral pH solutions
Lyudmila Nyrkova, Larysa Goncharenko, Yuriy Lisovskiy, Leonid Faynberg, Valeriy Kostin
Effect of Non-Essential Alloying Elements and Solution pH on Corrosion Behavior of Al-Mg Alloys Fabricated by Cold Spray Deposition
Munsu Kim, Luke N. Brewer, Gregory W. Kubacki
Effects of Al content on the mechanical properties and corrosion behavior of Ni-Al coatings on 310S heat-resistant steel for CSP plants
Shipeng Xu, Yuehong Zheng, Faqi Zhan, Peiqing La