Nowadays, the use of a linear anode in an impressed current cathodic protection system is one of the most interesting technical solutions to guarantee the corrosion protection of short pipe in common and even in congested area. The determination of the minimum distance between linear anode and pipe, and the effective parameters to reach the protection potential, can be studied at two different levels. First, the use of a primary current distribution analysis allows finding the proper distance based on the geometry, physical environmental parameters, and maximum allowable potential difference of two sides of the pipe. The second level is to consider the polarizability of the cathode, then to apply the so-called secondary current distribution analysis. The primary current distribution shows that the linear anode-to-pipe distance is mainly affected by soil resistivity and pipe diameter. Secondary current distribution analysis emphasizes that the proper minimum distance is influenced by the polarization of the cathode, i.e., the overvoltages of the two cathodic reactions of oxygen reduction and hydrogen evolution. In both approaches, soil resistivity has a predominant effect on potential distribution on the pipe surface.
Skip Nav Destination
Article navigation
1 September 2019
SCIENCE SECTION|
June 28 2019
Simulation of Linear Anode-Pipe Cathodic Protection System: Primary and Secondary Current and Potential Distribution Analysis
Mehdi Attarchi;
Mehdi Attarchi
‡
*Dipartimento di Chimica, Materiali e Ingegneria Chimica “G. Natta,” Politecnico di Milano, Via Luigi Mancinelli 7, Milan, Lombardia, 20131, Italy.
Search for other works by this author on:
Marco Ormellese;
Marco Ormellese
‡
*Dipartimento di Chimica, Materiali e Ingegneria Chimica “G. Natta,” Politecnico di Milano, Via Luigi Mancinelli 7, Milan, Lombardia, 20131, Italy.
Search for other works by this author on:
Andrea Brenna
Andrea Brenna
‡
*Dipartimento di Chimica, Materiali e Ingegneria Chimica “G. Natta,” Politecnico di Milano, Via Luigi Mancinelli 7, Milan, Lombardia, 20131, Italy.
Search for other works by this author on:
CORROSION (2019) 75 (9): 1128–1135.
Article history
Received:
November 23 2018
Revision Received:
June 28 2019
Accepted:
June 28 2019
Citation
Mehdi Attarchi, Marco Ormellese, Andrea Brenna; Simulation of Linear Anode-Pipe Cathodic Protection System: Primary and Secondary Current and Potential Distribution Analysis. CORROSION 1 September 2019; 75 (9): 1128–1135. doi: https://doi.org/10.5006/3113
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your InstitutionCiting articles via
Identification of Synergistic Interactions in Green Corrosion Inhibitor Mixtures by Molecular Modeling
Carlos M. Menendez, Oleg A. Mazyar, Sunder Ramachandran, Tracey Jackson
Resistance of the welded joint of X70 steel for main gas pipelines against corrosion-mechanical cracking under cathodic polarization in near-neutral pH solutions
Lyudmila Nyrkova, Larysa Goncharenko, Yuriy Lisovskiy, Leonid Faynberg, Valeriy Kostin
Effect of Non-Essential Alloying Elements and Solution pH on Corrosion Behavior of Al-Mg Alloys Fabricated by Cold Spray Deposition
Munsu Kim, Luke N. Brewer, Gregory W. Kubacki
Effects of Al content on the mechanical properties and corrosion behavior of Ni-Al coatings on 310S heat-resistant steel for CSP plants
Shipeng Xu, Yuehong Zheng, Faqi Zhan, Peiqing La