The chloride deposition rate is one of critical factors affecting the atmospheric corrosion of metals, which can be monitored by exposing Ag specimens and analyzing their surfaces using various ways. Although a coulometric reduction method can provide an absolute chloride deposition rate, new and alternative methods can be pursued, i.e., methods using typical surface analysis tools (scanning electron microscopy-energy dispersive x-ray spectroscopy [SEM-EDS], x-ray diffraction [XRD], and x-ray photoelectron spectroscopy [XPS]). As the surface analysis tools can only provide relative values, a correlation between the coulometric reduction and surface analyses should be developed. To develop the correlation between them, Ag specimens were prepared by exposing them to the atmosphere at 12 locations in South Korea for one year. Surface analysis of retrieved Ag specimens yielded correlations for the chloride deposition rates between the coulometric reduction method and typical surface analysis tools. Each correlation showed a fairly linear relationship, especially ones obtained from SEM-EDS and XPS. The developed correlations can be used when estimating the chloride deposition rate by using surface analysis tools as an alternative to the coulometric reduction method.
Skip Nav Destination
Article navigation
1 January 2021
Research Article|
November 08 2020
Quantitative Analysis Methods of Chloride Deposition on Silver for Atmospheric Corrosion Monitoring in South Korea
Wonjun Choi;
Wonjun Choi
*School of Mechanical Engineering, Pusan National University, Busan, 46241, South Korea.
Search for other works by this author on:
Dooyoul Lee;
Dooyoul Lee
**Aero Technology Research Institute, Daegu, 41052, South Korea.
Search for other works by this author on:
Chi Bum Bahn
Chi Bum Bahn
‡
*School of Mechanical Engineering, Pusan National University, Busan, 46241, South Korea.
‡Corresponding author. E-mail: [email protected].
Search for other works by this author on:
CORROSION (2021) 77 (1): 53–61.
Citation
Wonjun Choi, Dooyoul Lee, Chi Bum Bahn; Quantitative Analysis Methods of Chloride Deposition on Silver for Atmospheric Corrosion Monitoring in South Korea. CORROSION 1 January 2021; 77 (1): 53–61. doi: https://doi.org/10.5006/3622
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your InstitutionCiting articles via
Identification of Synergistic Interactions in Green Corrosion Inhibitor Mixtures by Molecular Modeling
Carlos M. Menendez, Oleg A. Mazyar, Sunder Ramachandran, Tracey Jackson
Resistance of the welded joint of X70 steel for main gas pipelines against corrosion-mechanical cracking under cathodic polarization in near-neutral pH solutions
Lyudmila Nyrkova, Larysa Goncharenko, Yuriy Lisovskiy, Leonid Faynberg, Valeriy Kostin
Effect of Non-Essential Alloying Elements and Solution pH on Corrosion Behavior of Al-Mg Alloys Fabricated by Cold Spray Deposition
Munsu Kim, Luke N. Brewer, Gregory W. Kubacki
Effects of Al content on the mechanical properties and corrosion behavior of Ni-Al coatings on 310S heat-resistant steel for CSP plants
Shipeng Xu, Yuehong Zheng, Faqi Zhan, Peiqing La