Countermeasures against the corrosion problems caused by seawater should be sufficiently considered at the spent fuel pool of the Fukushima Daiichi nuclear power plant. In this study, the corrosion behaviors of carbon steel in diluted synthetic seawater and the effect of a corrosion inhibition treatment were evaluated. Although the corrosion rate of the carbon steel in diluted synthetic seawater was high at the beginning of the test, it decreased to below 0.5 mm/y after 500 h. A clear effect of sodium nitrite (NaNO2) on corrosion inhibition was confirmed at a low flowrate, and the corrosion rate decreased to 0.004 mm/y at a flowrate of 3.2 m/s or less. The corrosion inhibition effect of sodium pentaborate (Na2B10O16) was confirmed at velocities ranging from 0.6 m/s to 5.3 m/s. The injection of Na2B10O16 is also effective for preventing the criticality of fuel. The corrosion rate of the carbon steel decreased gradually when the electrical conductivity of the electrolyte was progressively decreased. It was less than 0.1 mm/y when the electrical conductivity was less than 1.0 mS/m. When the electrical conductivity was progressively increased and exceeded 0.4 mS/m, the corrosion rate increased and shallow corrosion spots were produced.
Skip Nav Destination
Article navigation
1 January 2021
Research Article|
November 08 2020
Corrosion Behavior of Carbon Steel Piping in Flowing Diluted Seawater
Kazutoshi Fujiwara;
Kazutoshi Fujiwara
‡
*Central Research Institute of Electric Power Industry, 2-6-1 Nagasaka, Yokosuka, Kanagawa 240-0196 Japan.
‡Corresponding author. E-mail: [email protected].
Search for other works by this author on:
Junichi Tani;
Junichi Tani
*Central Research Institute of Electric Power Industry, 2-6-1 Nagasaka, Yokosuka, Kanagawa 240-0196 Japan.
Search for other works by this author on:
Joji Ohta;
Joji Ohta
*Central Research Institute of Electric Power Industry, 2-6-1 Nagasaka, Yokosuka, Kanagawa 240-0196 Japan.
Search for other works by this author on:
Yuichi Fukaya;
Yuichi Fukaya
**Tokyo Electric Power Company Holdings, 4-1, Egasaki-cho, Tsurumi-ku, Yokohama-shi 230-8510 Japan.
Search for other works by this author on:
Toshifumi Hirasaki
Toshifumi Hirasaki
**Tokyo Electric Power Company Holdings, 4-1, Egasaki-cho, Tsurumi-ku, Yokohama-shi 230-8510 Japan.
Search for other works by this author on:
CORROSION (2021) 77 (1): 62–71.
Citation
Kazutoshi Fujiwara, Junichi Tani, Joji Ohta, Yuichi Fukaya, Toshifumi Hirasaki; Corrosion Behavior of Carbon Steel Piping in Flowing Diluted Seawater. CORROSION 1 January 2021; 77 (1): 62–71. doi: https://doi.org/10.5006/3557
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your InstitutionCiting articles via
Improving the Long—Term Protection of Buried Steel Tanks: Considering the Impact of Temperature and Extended Sacrificial Anodes
Mohammad Javad Shirshahi, Seyed Farshid Chini, Peyman Taheri, Abraham Mansouri
Corrosion prediction model for long-distance pipelines based on NLFE-NGO-ELM
Xingyu Du, Yujie Dai, Bailing Zheng, Xinqi Zhu
Identification of Synergistic Interactions in Green Corrosion Inhibitor Mixtures by Molecular Modeling
Carlos M. Menendez, Oleg A. Mazyar, Sunder Ramachandran, Tracey Jackson
Resistance of the welded joint of X70 steel for main gas pipelines against corrosion-mechanical cracking under cathodic polarization in near-neutral pH solutions
Lyudmila Nyrkova, Larysa Goncharenko, Yuriy Lisovskiy, Leonid Faynberg, Valeriy Kostin
Effect of Non-Essential Alloying Elements and Solution pH on Corrosion Behavior of Al-Mg Alloys Fabricated by Cold Spray Deposition
Munsu Kim, Luke N. Brewer, Gregory W. Kubacki