The paper addresses the need for a fast and reliable method for field monitoring reinforced concrete structures. A proof of concept is presented where a noncontact procedure provides quantitative information on the concrete resistivity and reinforcement corrosion rate. A Wenner-type probe is presented, where a combination of two- and four-electrode measurements in a relatively high-frequency domain allows obtaining the information of interest. The method is based on the fact, verified by numerical simulations, that the embedded rebar works as an effective floating counter electrode and, thus, for distances higher than a critical value (1 cm in the simulations done), the ratio of concrete resistivity to the measured impedance at 1 kHz is constant and only dependent on the electrode diameter. The apparent polarization resistance measured with the four-electrode arrangement and normalized to the concrete resistivity allows obtaining the actual polarization resistance without contacting the rebar whose distance to the electrodes shall be known.
Skip Nav Destination
Article navigation
1 April 2023
Research Article|
December 27 2022
Two- and Four-Electrode Configurations for Contactless Reinforced Concrete Corrosion Monitoring
B. Díaz;
B. Díaz
*CINTECX, Universidade de Vigo, EEI, ENCOMAT Group, 36310 Vigo, Spain.
Search for other works by this author on:
X.R. Nóvoa;
X.R. Nóvoa
‡
*CINTECX, Universidade de Vigo, EEI, ENCOMAT Group, 36310 Vigo, Spain.
‡Corresponding author. E-mail: rnovoa@uvigo.es.
Search for other works by this author on:
C. Pérez;
C. Pérez
*CINTECX, Universidade de Vigo, EEI, ENCOMAT Group, 36310 Vigo, Spain.
Search for other works by this author on:
A. Pintos;
A. Pintos
*CINTECX, Universidade de Vigo, EEI, ENCOMAT Group, 36310 Vigo, Spain.
Search for other works by this author on:
V. Vivier
V. Vivier
**Sorbonne Université, CNRS, Laboratoire de Réactivité de Surface, Paris, France.
Search for other works by this author on:
CORROSION (2023) 79 (4): 419–425.
Citation
B. Díaz, X.R. Nóvoa, C. Pérez, A. Pintos, V. Vivier; Two- and Four-Electrode Configurations for Contactless Reinforced Concrete Corrosion Monitoring. CORROSION 1 April 2023; 79 (4): 419–425. doi: https://doi.org/10.5006/4200
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your Institution
69
Views
Citing articles via
Viability of Cathodic Protection for Preventing Corrosion of SS316H in Molten LiF-NaF-KF
Krishna Moorthi Sankar<span class='al-author-delim'>, </span>Preet Singh
Impact of fireside corrosion on creep rupture life and oxide scale structure of Super304H boiler tube
Xiaofeng Yang<span class='al-author-delim'>, </span>Yaxin Xu<span class='al-author-delim'>, </span>jintao lu<span class='al-author-delim'>, </span>Dangdang Ying<span class='al-author-delim'>, </span>Jinyang Huang<span class='al-author-delim'>, </span>Wenya Li
Optimizing Sour Gas Qualification Testing – Modeling the Effects of Temperature and Total Pressure on H<sub>2</sub>S Fugacity, Activity, and Solubility Coefficients
BRENT SHERAR<span class='al-author-delim'>, </span>Diana Miller<span class='al-author-delim'>, </span>Hui Li
Performance of a volatile corrosion inhibitor for mitigating corrosion under insulation
Yang Hou<span class='al-author-delim'>, </span>Thunyaluk Pojtanabuntoeng<span class='al-author-delim'>, </span>Mariano Iannuzzi<span class='al-author-delim'>, </span>Mike Rajagopal