The behavior of CO2 corrosion of mild steel was studied in a CaCO3 saturated aqueous solution. The bulk water chemistry ([Fe2+], [Ca2+], and pH) was controlled and the mass transfer characteristics inherent to the experimental setup were well defined. A combination of weight loss and electrochemical techniques, as well as surface characterization tools, were used to assess the behavior of corrosion products over long-term experiments. Three corrosion periods were identified based on the analysis of the corrosion rates and Nyquist response values versus exposure time. Residual Fe3C was the early corrosion product; however, FexCayCO3 (x + y = 1) precipitated within its pores over the course of experiments where a favorable local water chemistry was achieved, regardless of the bulk solution. Results show that the presence of Ca2+ did not jeopardize the final protectiveness of corrosion products.

Localized corrosion is typically influenced by the anionic species in electrolytes. However, localized corrosion has been also attributed to the inhomogeneity of the corrosion product layer in the presence of Ca2+, as a cationic species.1  There are a number of contradictions in the open literature regarding the effect of Ca2+ on uniform and localized corrosion of mild steel in CO2 environments.2  This is often due to inadequate experimental setups and procedures, which fail to ensure consistent control of solution chemistry, such as pH and degree of CaCO3 saturation. Aqueous speciation is one of the most influential parameters that governs both scaling and corrosion processes. The degree of aqueous saturation of CaCO3 and FeCO3 is a key parameter, even more important than individual ion concentrations, when studying the effect of Ca2+ ions on CO2 corrosion. The precipitation kinetics of solid CaCO3 and FeCO3 are greatly influenced by the bulk saturation degree, as the main driving force, rather than individual ion concentrations.3  An electrolyte can have a high concentration of Ca2+ but still be undersaturated with respect to CaCO3; bulk precipitation is not expected. Saturation degree depends on several environmental parameters, such as relevant ion concentration, pH, temperature, ionic strength, etc. Researchers often overlooked saturation degree, exclusively relying on ion concentrations as the core influencing parameter on CO2 corrosion. pH is a critical parameter which has a considerable effect on corrosion rate as well as CaCO3 and FeCO3 precipitation rates. Many studies published on the effect of Ca2+ on CO2 corrosion describe experiments where the initial and final solution pH values are not the same due to changes of water chemistry over the course of long-term experiments. In some cases, even the initial pH is not reported at all.4,-5  The corrosion behavior and the formation of corrosion product layers and scales are also influenced by mass transfer of key ions from/to the bulk solution and through surface layers.6  Mass transfer rate influences the concentration of the aqueous species near the corroding metal surface, which constitutes the active site for precipitation of metal carbonates. Consequently, the morphology and other properties of the surface layers can be considerably affected by mass transfer characteristics. Experimental data generated by a setup with well-defined mass transfer characteristics for studying the effect of Ca2+ on CO2 corrosion ensures reproducibility.

In the research reported herein, methodologies were developed to overcome reported experimental difficulties and to obtain more reliable and repeatable results when studying the influence of Ca2+ on mild steel CO2 corrosion mechanisms. The results were obtained in a system where the water chemistry of the test environment was tightly controlled over the course of the experiments, and where mass transfer characteristics were also well-defined. An extended version of this research letter is available for more detailed analysis and discussion.7  However, in the current manuscript, electrochemical impedance spectroscopy (EIS) data with relevant discussion are provided.

Figure 1 shows the experimental setup, equipped with fixed specimen holders and an impeller for generating uniform mass transfer characteristics across the specimen surfaces. These advancements were introduced to eliminate nonuniformity of flow and mass transfer experienced by unstable hanging specimens, as in the conventional glass cell setup used in a previous study.8  pH and [Fe2+] were controlled using H-form and Na-form ion-exchange resins, installed in two independently controlled flow loops attached to the glass cell. For more explanations about the effectiveness of the ion-exchange resins and their function in corrosion studies, please refer to the publication by Zhong, et al.9  The test solutions were kept saturated with respect to CaCO3 over the course of 7 d experiments, corresponding to a stable [Ca2+] of ca. 160 ppm, by maintaining a deposit of solid CaCO3 at the bottom of the glass cell. The [Ca2+] was measured at the beginning and end of experiments using inductively coupled plasma spectroscopy.

FIGURE 1.

Schematic of the experimental setup equipped with fixed specimen holders and impeller, capable of controlling water chemistry.

FIGURE 1.

Schematic of the experimental setup equipped with fixed specimen holders and impeller, capable of controlling water chemistry.

Close modal

Defining the hydrodynamic and mass transfer characteristics of any new experimental corrosion setup is essential when studying the influence of flow on corrosion, and helps ensure reproducibility of the results.10  In the current experimental setup, the limiting current of a ferri-ferrocyanide coupled electrochemical reaction, Equation (1), was used to define the mass transfer coefficient.

(1)

The dependence of the Sherwood (Sh) number on the Reynolds (Re) and Schmidt (Sc) numbers was defined by performing multiple regressions to calculate the unknown constants pertaining to the specific geometry of the glass cell setup with this impeller. The final empirical relationship is shown in Equation (2).

(2)

Two series of corrosion experiments were performed (and repeated), one without Ca2+ ions (as a baseline) and one in a CaCO3 saturated electrolyte. Other than that, both tests were conducted under the same experimental conditions as described in Table 1. The experiments were conducted at atmospheric pressure at 80°C and 0.53 bar (53 kPa) pCO2. After addition of 1 wt% NaCl (to both electrolytes), CaCO3 reagent (to the electrolyte containing Ca2+), or NaHCO3 (to the baseline electrolyte), the electrolytes were deoxygenated by sparging with CO2 for at least 2 h prior to the start of each experiment. At the same time, the solution was heated to 80°C, leading to a water vapor pressure of 0.47 bar (47 kPa) with the balance gas being CO2. In these conditions, the autogenous initial pH for the electrolyte in the presence of the CaCO3 reagent was pH 6.2 at equilibrium. Therefore, to have similar testing environments, the pH of the baseline electrolyte (without any Ca2+) was initially adjusted to 6.2 (using NaHCO3). CO2 gas was continuously bubbled into the solutions to maintain saturation with CO2 during corrosion experiments. During the experiments, the pH was maintained at 6.2±0.1 by the means of H-form ion-exchange resin (Dowex® G26). The [Fe2+] was controlled to be no greater than 10 ppmw using a Na-form ion-exchange resin (Amberlite® IR 120). The CaCO3-saturated solution initially contained 1.2 g/L powdered CaCO3 reagent with 99% purity (ACROS Organics™). This excess amount of CaCO3 in the solution was calculated, using the solubility of CaCO3 in the experimental condition presented in Table 1, to be three times higher than what was needed for the solution to remain saturated with respect to CaCO3 over the course of the long-term experiments. Although a portion of the [Ca2+] in the electrolyte was potentially, and unwantedly, removed by the ion-exchange resins, the excess CaCO3 reagent guaranteed that the solution remained saturated with respect to CaCO3 with a stable [Ca2+] due to the relatively fast kinetics of CaCO3 precipitation/dissolution.11  A three-electrode configuration (including UNS G10180(1) material as working electrode, Ag/AgClsat. reference electrode, and Pt counter electrode) was used along with a Gamry Reference 600™ potentiostat to conduct electrochemical measurements.

Table 1.

Experimental Conditions

Experimental Conditions
Experimental Conditions

Figure 2 shows a comparison of corrosion rate (CR) obtained by linear polarization resistance (LPR) and open-circuit potential (OCP) for experiments with and without Ca2+ over time. A proportional constant of 26 mV (B value) was used for calculation of corrosion rate based on Stern-Geary theory.12  It is understood that the value selected may be dependent on the specific testing conditions and may even change over the course of experiments. However, LPR data are used for trends rather than for obtaining values of corrosion rates which are measured more accurately by the weight loss method. Three corrosion periods can be identified in Figure 2 for experiments with and without Ca2+:

  • 1. Active corrosion (development of Fe3C);

  • 2. Nucleation/growth of surface layers (corrosion products);

  • 3. Pseudo-passivation (further growth of corrosion products).

FIGURE 2.

Comparison of corrosion rate and OCP over time for experiments with and without Ca2+.

FIGURE 2.

Comparison of corrosion rate and OCP over time for experiments with and without Ca2+.

Close modal

A longer active corrosion period was observed in the presence of 160 ppm Ca2+. That may suggest that the presence of Ca2+ was interfering with the precipitation of FeCO3, slowing the processes of nucleation and/or growth. However, when the corrosion products are fully developed on the substrate, in the pseudo-passivation period, an identical corrosion rate is achieved with or without Ca2+. Profilometry of the specimens after removal of corrosion products showed no localized corrosion for both electrolytes (baseline and CaCO3-saturated).

EIS measurements agreed with the LPR measurements in identifying the three corrosion periods. The impedance signatures for both series of experiments hold some similarities and differences. In order to show these characteristics, an example of EIS Nyquist data related to a CaCO3-saturated solution is presented and interpreted.

Active Corrosion Period

Figure 3(a) shows the Nyquist plot evolution in this time period. Three time constants can be identified in this period. Two depressed capacitive semicircles and an inductive loop in the low-frequency (LF) range are obvious. The capacitive semicircle, in the high- (HF) to medium- (MF) frequency range, is related to the resistance of charge-transfer in the double-layer at the steel/solution interface and is inversely proportional to the corrosion rate.13  The second semicircle in the MF-LF range is related to development of a residual Fe3C skeleton which remains due to the preferential corrosion of the α-Fe phase.14  The presence of an inductive loop in a CO2 corrosion environment is usually associated with an adsorbed intermediate product.15  The magnitude of the inductive loop is decreasing with time as more conductive Fe3C is exposed on the steel substrate, resulting in acceleration of hydrogen reduction. This is also reflected in the decrease of the overall impedance with time in this corrosion period. The inductive loop disappears after 74 h of exposure at the end of this period.

FIGURE 3.

Nyquist plots obtained for a UNS G10180 over time exposed to CaCO3-saturated solution (160 ppm Ca2+) at 80°C, pCO2 0.53 bar, bulk solution pH 6.2, 0.18 M ionic strength, and 20 rpm: (a) active corrosion period and (b) nucleation/growth of corrosion products and pseudo-passivation periods.

FIGURE 3.

Nyquist plots obtained for a UNS G10180 over time exposed to CaCO3-saturated solution (160 ppm Ca2+) at 80°C, pCO2 0.53 bar, bulk solution pH 6.2, 0.18 M ionic strength, and 20 rpm: (a) active corrosion period and (b) nucleation/growth of corrosion products and pseudo-passivation periods.

Close modal

From 51 h to 74 h of exposure, the corrosion rates are near identical. This behavior could be explained by the balance between Fe3C formation, which tends to increase the corrosion rate and the development of less aggressive water chemistry within the pores of Fe3C where an increase of 2 to 3 pH units can be expected.

Nucleation/Growth of Corrosion Product Period

This period roughly starts from 74 h of exposure with the nucleation of corrosion products happening within the pores of Fe3C. Consequently, the corrosion rate decreases continuously as their further growth confers more protection against corrosion.

Pseudo-Passivation Period

The pseudo-passivation period, which starts roughly after 99 h of exposure, is characterized by a low and steady corrosion rate and a higher OCP value (see Figure 2). The formation of a dense corrosion product layer is also achieved (supported by surface characterization, not shown in this manuscript7 ).

The Nyquist plots corresponding to the nucleation/growth and pseudo-passivation periods are provided in Figure 3(b). They show two incomplete semicircles with increasing diameters over time. This behavior is due to precipitation and growth of corrosion products.16  In addition, the inductive loops have disappeared completely.

  • The presence of Ca2+ ions, while the solution is saturated with respect to CaCO3, did not jeopardize the protectiveness conferred by corrosion products in long-term CO2 corrosion experiments nor initiated localized corrosion. Three corrosion periods were identified for corrosion of mild steel: active corrosion, nucleation/growth of corrosion products, and pseudo-passivation periods. Initially, residual Fe3C constituted the main corrosion product. However, its pores became filled with FexCayCO3 (x + y = 1) over the course of the experiments as a favorable water chemistry was achieved near the steel surface, regardless of the bulk solution.

Trade name.

(1)

UNS numbers are listed in Metals and Alloys in the Unified Numbering System, published by the Society of Automotive Engineers (SAE International) and cosponsored by ASTM International.

The authors would like to thank the following companies for their financial support: Anadarko, Baker Hughes, BP, Chevron, CNOOC, ConocoPhillips, DNV GL, ExxonMobil, M-I SWACO (Schlumberger), Multi-Chem (Halliburton), Occidental Oil Company, PTT, Saudi Aramco, SINOPEC (China Petroleum), and TOTAL.

1.
S.N.
Esmaeely
,
D.
Young
,
B.
Brown
,
S.
Nešić
,
Corrosion
73
(
2017
):
p
.
238
246
.
2.
H.
Mansoori
,
D.
Young
,
B.
Brown
,
M.
Singer
,
J. Nat. Gas Sci. Eng.
59
(
2018
):
p
.
287
296
.
3.
T.H.
Chong
,
R.
Sheikholeslami
,
Chem. Eng. Sci.
56
(
2001
):
p
.
5391
5400
.
4.
C.
Ding
,
K.
Gao
,
C.
Chen
,
Int. J. Miner. Metall. Mater.
16
(
2009
):
p
.
661
666
.
5.
G.X.
Zhao
,
L.
Jian-Ping
,
H.
Shi-Ming
,
L.U.
Xiang-Hong
,
J. Iron Steel Res. Int.
12
(
2005
):
p
.
38
42
.
6.
S.
Nešić
,
Energy Fuels
26
(
2012
):
p
.
4098
4111
.
7.
H.
Mansoori
,
D.
Young
,
B.
Brown
,
S.
Nešić
,
M.
Singer
,
Corros. Sci.
158
(
2019
):
article id 108078
.
8.
S.N.
Esmaeely
,
Y.-S.
Choi
,
D.
Young
,
S.
Nešić
,
Corrosion
69
(
2013
):
p
.
912
920
.
9.
X.
Zhong
,
B.
Brown
,
W.
Li
,
S.
Nešić
,
M.
Singer
,
“How to Maintain a Stable Solution Chemistry when Simulating CO2 Corrosion in a Small Volume Laboratory System,”
CORROSION 2016
,
paper no. 7780
(
Houston, TX: NACE International
,
2016
).
10.
D.C.
Silverman
,
Corrosion
60
(
2004
):
p.
1003
1023
.
11.
N.
Spanos
,
P.G.
Koutsoukos
,
J. Phys. Chem. B
102
(
1998
):
p
.
6679
6684
.
12.
M.
Stern
,
A.L.
Geary
,
J. Electrochem. Soc.
104
(
1957
):
p
.
56
63
.
13.
Z.
Zeng
,
R.S.
Lillard
,
H.
Cong
,
Corrosion
72
(
2016
):
p
.
805
823
.
14.
F.
Farelas
,
M.
Galicia
,
B.
Brown
,
S.
Nešić
,
H.
Castaneda
,
Corros. Sci.
52
(
2010
):
p
.
509
517
.
15.
G.A.
Zhang
,
Y.F.
Cheng
,
Corros. Sci.
51
(
2009
):
p
.
87
94
.
16.
J.L.
Mora-Mendoza
,
S.
Turgoose
,
Corros. Sci.
44
(
2002
):
p
.
1223
1246
.

Author notes

Recipient of first place in the Mars Fontana Corrosion Engineering category at CORROSION 2019, March 2019, Nashville, Tennessee.