A field study investigated penetration of outdoor ground ultra-low–volume (ULV) aerosol and thermal fog adulticide applications into a dwelling to control the dengue vector Aedes aegypti (L). Four applications of Kontrol 4-4 (4.6% permethrin active ingredient [AI], 4.6% piperonyl butoxide) at the maximum label rate were made at 25–30 m in front of a house at Camp Blanding Joint Training Center, Starke, FL, during summer 2016. The ULV sprayer and thermal fogger nozzles were oriented horizontally, and vehicle travel speeds were 16 and 24 km/h, respectively. All doors and windows of the house were left open. Spray efficacy was assessed using caged female mosquitoes positioned 30 cm above ground, outside and inside of the house. Interior cages were placed in open areas and cryptic sites (i.e., in a closet or cardboard box). A spinner holding 2 rods sized 3 mm × 75 mm was deployed next to each cage (except cryptic sites) to sample droplets and to quantify AI deposition. Thirty minutes after application, cages were removed, slides collected, and mosquitoes transferred to clean cages in the laboratory where mortality was assessed at 24 h posttreatment. The ULV application to the south side of the house produced 100% mortality in outdoor and indoor cages and 24% mortality at cryptic sites. Similarly applied thermal fog resulted in 85% mortality outdoors, 34% indoors, and only 4% in cages at cryptic sites. Application of either method from the west resulted in 19–61% mortality outdoors and 0.5–6.5% indoors. Droplet volume median diameter (Dv0.5) on rods from the ULV application was significantly larger compared with the thermal fogger outdoors, but similar indoors. Outdoors and indoors, the AI deposition from ULV was significantly higher than from thermal fog. Our results show the potential for controlling dengue vectors inside houses with outdoor ground ULV applications in areas where doors and windows are left open for ventilation.

Dengue is a globally important disease and is reportedly causing more deaths than any other arboviral infection (Jacobs 2000). Hales et al. (2002) predicted that approximately 50–60% of the world's population would be living in areas at risk of dengue transmission by 2085. Unfortunately, this level was surpassed in 2007 (Heintze et al. 2007) due to increasing epidemiological trends and geographic expansion over the last 40 years (WHO 2007), as well as increased urbanization.

Suppression of dengue, in the absence of a vaccine, continues to rely on vector control methods (Jacobs 2000, Heintze et al. 2007, Harburguer et al. 2012, Murray et al. 2013). These methods may include biological and chemical vector control and environmental management strategies, as well as personal protection. Indeed, effective vector control methods are recognized as essential and continue to be promoted globally by the World Health Organization (WHO) through the strategic approaches of integrated vector management. During disease emergencies, ultra-low–volume (ULV) space sprays are the primary method to quickly suppress adult vector populations (Perich et al. 2000, Farooq et al. 2017). In addition, the WHO has included integration of chemical and nonchemical control methods as one component of their global strategy for dengue prevention and control (WHO 2012). This policy remains their focus in managing container-inhabiting Aedes vectors in areas where high risk of human–vector contact occurs (Murray et al. 2013).

Dengue vectors such as Aedes aegypti (L.) and Ae. albopictus (Skuse) are found inside and around human habitats (Perich et al. 2000, Chadee 2013, Manzanilla et al. 2017). Suppression of local vector populations can be especially challenging when dwellings are open to the outdoor environment thereby increasing the risk of mosquito–human contact. Such situations are common in many tropical countries as well as on US military forward operating bases.

Traditionally, indoor mosquitoes, primarily Anopheles species, have been controlled with indoor residual sprays (IRS). However, this method is not generally recommended for dengue vector control, since specimens of adult Ae. aegypti prefer cryptic harborage areas, such as clothing in a closet, instead of resting on walls (Esu et al. 2010).

Indoor and outdoor ULV sprays have been previously evaluated for control of adult Ae. aegypti inside dwellings. Harwood et al. (2014) reported that indoor applications of the adulticide ULD BP-300 (synergized pyrethrins) with hand-held thermal fogger and backpack ULV sprayer provided 93–100% and 88–100% mortality, respectively, of caged Ae. aegypti. Another study on indoor application of ULD BP-300 and 9M Plus2 (deltamethrin) indicated that mortality of caged mosquitoes in the middle of a room ranged from 59% to 100% and 94% to 100% from thermal fog and ULV, respectively (Ponlawat et al. 2017). Moreover, the mortality in cryptic areas (inside closed paper bags) ranged from 3% to 46% and 6% to 72% from thermal fog and ULV, respectively (Ponlawat et al. 2017). Such applications, even with their promising efficacy, are limited in their utility to isolated homes and smaller communities due to time and personnel requirements. An effective technique to achieve indoor protection over larger areas does not exist.

Perich et al. (1992) reported that malathion aerosol droplets from ULV ground and aerial applications penetrated into dwellings and further interior areas (i.e., bedroom closets, under beds). Unfortunately, this study did not measure mosquito mortality in relation to droplet penetration. However, the authors found that droplet volume median diameter averaging 4 μm in the interior areas of the house that resulted in approximately 2 min of “potential insecticide exposure” may be sufficient for vector contact. Sudsom et al. (2015) suggested indoor ULV as an effective method of space spraying, which has greater potential to control indoor adult dengue vector populations than outdoor ULV spraying. They found that indoor mosquito density was not significantly different between outdoor and indoor ULV sprays 2 days before and 6 days after space spraying, but the density after the indoor sprays was significantly less than the density after the outdoor sprays at 1 and 2 days postspraying. Chadee (1985) reported that ground ULV application of malathion resulted in 55% control of caged Ae. aegypti outdoors but only about 23% in similarly caged mosquitoes indoors. Harburguer et al. (2012) compared indoor control of caged Ae. aegypti with that of outdoors when applied with either an outdoor thermal or cold fogger of a mixture of permethrin and pyriproxyfen. The authors found that outdoor control using the cold fogger ranged from about 65% to 86%, while indoor control ranged from about 23% to 58%. These studies showed not only the lack of spray penetration, but also a lack of outdoor control, which may have been due to inappropriate applications. The varying results of these applications indicate the need for improvements in application methodology, as well as the need for studying its potential for indoor control. In previous studies we have optimized outdoor ULV aerosol application efficacy by changing nozzle orientation (Farooq et al. 2017) and travel speed (Farooq et al. 2018). This information encouraged us to evaluate the impact of outdoor ULV adulticide applications on indoor resting mosquitoes. Therefore, the objective of our study reported herein was to investigate the effectiveness of outdoor adulticide application using optimized settings of conventional truck-mounted ULV aerosol and thermal fog equipment for the control of indoor Ae. aegypti.

The study was conducted at Camp Blanding Joint Training Center, Starke, FL (29°55′26.4″N, 81°59′49.7″W) using a single-story house at the intersection of Duval Road and Yerks Road (Fig. 1). The house is 43 m north of Yerks Road and 30 m east of Duval Road and consists of 2 bedrooms, a living room, kitchen, bathroom, and a storage area. This house is used for training drills of law enforcement personnel and simulates a poorly managed house. The dwelling has 8 windows with an entrance door on the south side, 4 windows on the west side, 5 windows on the north side, and another entrance door and window on the east side.

Fig. 1.

Aerial view of the study site.

Fig. 1.

Aerial view of the study site.

Close modal

Figure 2 shows that 9 screened 9-cm-diameter 6-cm-deep paper cages containing 25 adult female Ae. aegypti were placed inside the house, of which 5 cages (BN2, BS, LW, LE, and KI) were in the open area of 4 different rooms, 1 in a closet (CU), 2 in the cardboard boxes (DR and BN), and 1 in a storage closet (ST). Figure 2 also shows 10 cages were placed outdoors, 3–5 m from the house, of which 3 (FW, FM, and FE) were on the south, 3 (RW, RM, and RE) on the north, 2 (ES and EN) on the east, and 2 (WN and WS) on the west of the house. A Florida Latham Bond (FLB) spinner (John W. Hock, Co., Gainesville, FL) with 2 rods size 3 mm × 75 mm was deployed 1 m away from each outdoor cage to collect spray for droplet size and deposition analysis. Likewise, a spinner was placed 1 m away from each indoor cage only in the open area (Fig. 2). Each spinner had a Teflon® coated rod for droplet size determination and a plain rod for deposition analysis. All cages and spinners were 30 cm above ground because the vast majority of indoor Ae. aegypti typically rest within 1.5 m from the floor (Manzanilla et al. 2017).

Fig. 2.

Building and location of mosquito bioassay cages and droplet sample spinners.

Fig. 2.

Building and location of mosquito bioassay cages and droplet sample spinners.

Close modal

Kontrol 4-4 adulticide (4.6% permethrin active ingredient [AI], 4.6% piperonyl butoxide; Univar Environmental Sciences, Austin, TX) was applied at the maximum label rate (195 ml/ha) as an outdoor ULV space spray and thermal fog. For ULV sprays, oil-soluble Yellow 131SC® fluorescent dye (Rohm and Haas Co., Philadelphia, PA) was mixed with the pesticide at 25,000 ppm. These applications were conducted using a truck-mounted Cougar® ULV sprayer (Clarke Mosquito Control, Roselle, IL) traveling at 16 km/h, nozzle discharging horizontally and out the back of the truck at 473 ml/min. We elected to adjust the nozzle orientation based on favorable ULV application results where complete mortality of caged Ae. aegypti occurred up to 90 m from the spray nozzle (Farooq et al. 2017). For thermal fog sprays, 1 part of pesticide was diluted with 1.8 parts of BVA-13 mineral oil (BVA Inc., New Hudson, MI), and fluorescent dye was mixed at 12,000 ppm. These applications were made using a truck-mounted Swingfog® SN101 thermal fogger (Swingtec GmbH, Isny, Germany) traveling at 24 km/h, nozzle discharging insecticide horizontally and out the back of the truck at a flow rate of 2.0 liter/min. All windows and doors of the house were opened before spraying and remained open until all cages and slides were collected.

During all applications, the sprayer/fogger traveled either 25 m south of the house parallel to Yerks Road or 30 m west of the house on Duval Road, depending on wind direction (Table 1). These distances were selected to avoid trees on the south side and a ditch on the west side. Adulticide application with both pieces of equipment was conducted on each day on April 20, May 4, May 11, and May 18, 2016. On each day, ULV and thermal fog applications were rotated. Wind speed, direction, temperature, and relative humidity were recorded 3 m above ground. Based on ambient wind conditions, sprayer travel direction was changed. Sprayer travel path and weather conditions for all applications on different days are provided in Table 1. After each application, 3 exhaust floor fans were deployed inside the house for 30 min to clear the air out of the building before preparation for the next application.

Table 1.

Calendar dates, times, vehicle travel direction, and ambient weather conditions during ultra-low–volume (ULV) and thermal fog (TF) insecticide applications at Camp Blanding Joint Training Facility, Starke, FL in 2016.

Calendar dates, times, vehicle travel direction, and ambient weather conditions during ultra-low–volume (ULV) and thermal fog (TF) insecticide applications at Camp Blanding Joint Training Facility, Starke, FL in 2016.
Calendar dates, times, vehicle travel direction, and ambient weather conditions during ultra-low–volume (ULV) and thermal fog (TF) insecticide applications at Camp Blanding Joint Training Facility, Starke, FL in 2016.

Thirty minutes after application, mosquito cages were removed and transported to the onsite laboratory. Mosquitoes were lightly knocked down with CO2, transferred to clean cages, supplied with 10% sugar solution, and moved to Navy Entomology Center of Excellence (NECE) laboratory, where they were kept at room conditions until 24-h mortality was recorded. Control cages were exposed to the same environment but away from the application area and subjected to the transfer process. At the time of cage retrieval, Teflon coated slides were removed and stored in prelabeled boxes for droplet size measurements while plain slides were stored in prelabeled resealable plastic bags and stored in a cool, dark place. All slides were then returned to NECE and stored in a refrigerator until analyzed.

Droplets on rods were measured with DropVision system (Leading Edge Associates Inc., Fletcher, NC) and droplet distribution parameters (Dv0.1, Dv0.5, and Dv0.9) determined. The Dv0.1, Dv0.5, and Dv0.9 are the droplet diameters (μm) where 10%, 50%, and 90% of the spray volume is contained in droplets smaller than these diameters (ASTM Standard E1620 [ASTM 2004]). Insecticide deposition was quantified using procedures described by Farooq et al. (2009). Rods were washed using 20 ml hexane inside the plastic bag, and fluorescence readings of the resultant solution were measured with a spectrofluorophotometer (Model RF5000U; Shimadzu, Kyoto, Japan). The amount of dye on each rod was determined using calibration curves developed from standard concentrations. The amount of dye on each slide was then converted to AI deposition (ng/cm2) using a sampling area of 63 cm2 and the ratio of dye and AI in the spray tank.

Statistical analyses

Mean treatment mortality data were corrected prior to analyses with that of controls using the formula of Abbott (1925). Intel® Visual FORTRAN Composer XE 2013 software was used to statistically analyze the data with α = 0.05. Initial Kolmogorov–Smirnov tests (Smirnov 1939) performed on all data sets revealed that the data were nonnormally distributed, while the Bartlett test (Bartlett 1937) showed nonhomogeneity of variances. For analysis, mean mortality data were grouped into 3 zones (outdoor, indoor [cages in the open], and indoor cryptic sites). Mean droplet size and deposition data were grouped into 2 zones (outdoor and indoor), because there were no spinners at cryptic sites. A 3-way Kruskal–Wallis (KW) analysis (Kruskal and Wallis 1952) was conducted to assess differences in 24-h mortality, Dv0.5, and AI deposition for the 2 sprayers, 2 or 3 zones, and 4 application dates. Since the application date significantly affected these data, a 2-way nonparametric KW analysis was conducted to study the effect of sprayer and zone on data for each application date. Subsequent post hoc Scheffe multiple-contrast tests (Scheffe 1959) were conducted to identify effects of those sprayers and zones, which were significantly different from each other.

The data showed a significant difference in outdoor 24-h mortality (X2 = 9.00, df1 = 1, df2 = 78, P = 0.0035), and a nonsignificant difference in indoor 24-h mortality (X2 = 0.9849, df1 = 1, df2 = 36, P = 0.3474), as well as in mortality at cryptic indoor sites (X2 = 2.5976, df1 = 1, df2 = 30, P = 0.1118) between the 2 sprayers (Table 2). Generally, mean mosquito mortality was higher in all indoor and outdoor cages from the ULV application when compared with the thermal fogger application, but this difference was only significant outdoors. The Dv0.5 was significantly affected by sprayers outdoors (X2 = 11.7654, df1 = 1, df2 = 69, P < 0.0001) but not indoors (X2 = 0.6915, df1 = 1, df2 = 31, P = 0.4319). Droplet Dv0.5 from the ULV sprayer was always larger than from the thermal fogger, but again the difference was only significant outdoors. In contrast, the AI deposition was significantly affected by sprayers outdoors (X2 = 5.4758, df1 = 1, df2 = 38, P = 0.0208) and indoors (X2 = 15.6094, df1 = 1, df2 = 78, P < 0.0001). The AI deposition from the ULV sprayer was significantly higher than from the thermal fogger both indoors and outdoors.

Table 2.

Comparison of overall mean (±SE) adult Aedes aegypti mortality, Dv0.5, and active ingredient (AI) deposition between 2 sprayers at different zones.

Comparison of overall mean (±SE) adult Aedes aegypti mortality, Dv0.5, and active ingredient (AI) deposition between 2 sprayers at different zones.
Comparison of overall mean (±SE) adult Aedes aegypti mortality, Dv0.5, and active ingredient (AI) deposition between 2 sprayers at different zones.

Table 1 shows considerable differences in ambient environmental conditions including prevailing wind direction occurred on different days during the study. Thus, mosquito mortality (the ultimate indicator of effectiveness of an application) was examined on individual spray days. Figure 3 shows mosquito mortality from 2 sprayers in 3 sampling zones on 4 spray days, which indicated that applications performed on May 4 and May 18 resulted in poor mortality and AI deposition in all zones for both sprayers, especially the thermal fogger, compared with the other 2 dates. Figure 3 and Table 2 show that the thermal fogger in general performed poorly.

Fig. 3.

Mean (±SE) comparison of adult Aedes aegypti mortality from ultra-low–volume and thermal foggers in cages placed at different zones on different dates. Means with different letters at each date, within a zone, are significantly different (Scheffe 1959). α = 0.05.

Fig. 3.

Mean (±SE) comparison of adult Aedes aegypti mortality from ultra-low–volume and thermal foggers in cages placed at different zones on different dates. Means with different letters at each date, within a zone, are significantly different (Scheffe 1959). α = 0.05.

Close modal

On April 20, the ULV sprayer resulted in significantly higher indoor and outdoor mortality of caged Ae. aegypti than the thermal fogger (Fig. 3). The ULV application also resulted in higher mortality at cryptic sites, but the difference was not significant. Also, on this day, the ULV had similar mortality outdoors and indoors but lower mortality at cryptic sites. On May 4, the ULV had significantly higher mortality outdoors and at cryptic sites than the thermal fogger, but the overall mortality was not satisfactory. On May 11, the ULV and thermal fogger resulted in complete mortality outdoors, but the thermal fog failed to penetrate the dwelling (Fig. 3). In contrast, the ULV had complete mortality indoors and considerable mean mortality (29%) at cryptic sites. On May 18, both sprays had similarly low mortality.

The dengue vector Ae. aegypti is commonly found in human dwellings. Manzanilla et al. (2017) reported that the vast majority (98%) of this species rested in bedrooms, living rooms, bathrooms, and kitchen. Because individuals predominately (82%) rest within 1.5 m of the floor, and not necessarily on walls, IRS is not a suitable option for their control (Esu et al. 2010, Manzanilla et al. 2017). However, indoor ULV sprays have shown promise (Mani et al. 2005, Harwood et al. 2014, Ponlawat et al. 2017) but are neither logistically suitable nor scalable for larger areas. With the adjustment of nozzle orientation and travel speed of truck-mounted ULV sprayers, complete mortality of caged female Ae. aegypti was achieved in an open area beyond 90 m from the spray (Farooq et al. 2017, 2018). Encouraged by these results, and by the Perich et al. (1992) study where ULV ground application of malathion penetrated into dwellings and further interior areas, this study was planned to examine the potential of ground ULV sprays to penetrate dwellings to control these vectors.

Our results indicate that the ULV application of Kontrol 4-4 produced higher adult Ae. aegypti mortality compared with thermal fog. Furthermore, the spray performed considerably better when applied from the south versus the west side of the house. These results show that the right conditions (wind speed and direction) provided complete mortality of caged Ae. aegypti indoors and outdoors with the ULV applications (April 20, May 11). Also, on these dates, ULV spray produced considerable mean mortality (29%) at cryptic locations further inside the house. It should be noted that these sprays were conducted in the morning, mostly in the absence of temperature inversion.

Based on these results, the authors can envision that by using the right combination of sprayer and weather conditions, a single ULV spray can control Ae. aegypti, not only outdoors, but also inside buildings. The results also indicate that a properly managed, single application can make it a 2-in-1 application to control day time biting mosquitoes resting indoors and outdoors. However, more studies are needed to refine the technique.

Elaboration on some of the factors that played a role during this study may be helpful to understand these results and the potential of this type of application. The available sprayer was able to produce a ULV spray, but the droplet spectrum was inclined toward the upper acceptable limit (Hoffmann et al. 2012). The pesticide was selected from the Department of Defense National Stock List, which has a 5-fold higher application rate than other commercially available adulticides, increasing droplet size (Farooq et al. 2016) and requiring larger amounts of spray to penetrate indoors. Also, due to the limit of maximum flow rate of the sprayer, the intended 24 km/h travel speed could not be achieved. Using lower-dose adulticides may improve the efficacy and penetration.

There were few openings for the spray to enter the house from the west side. The penetration was also subdued by thick bushes between the spray release and the house. The location of the house was isolated with a forest border surrounding most of its northern side. Local wind patterns often render it difficult to target such a small area of a single house. Changing wind direction can affect the efficacy of the treatment, providing highly variable results between treatment dates. A spray that misses the target structure is lost. If this type of application occurred in an operational setting and if a spray misses a house, it can potentially move through the neighborhood, penetrate another house, and still impact local mosquito populations. It is expected that this spray technique can perform better in a real, more natural environment, and future work should include trials in villages or operational settings.

Because of a ditch between the house and the road on the west side, distance between the house and truck travel path had to be increased. That might have contributed to poor efficacy from sprays on the west side. This shows the need to investigate the effect of this distance on control of vectors indoors.

This study was supported in part by a grant from the Deployed War-Fighter Protection Research Program, funded by the US Department of Defense through the Armed Forces Pest Management Board. We acknowledge the help from Jessika Blersch, Environment Division, Camp Blanding Joint Training Center for providing the study site, and NECE staff for field and laboratory work. The views expressed in this article are those of the authors and do not necessarily reflect the official policy or position of the Department of the Navy, Department of Defense, nor the US Government. EMS and EJL are military service members, and JEC an employee of the US Government. This work was prepared as part of their official duties. Title 17, U.S.C., §105 provides that copyright protection under this title is not available for any work of the US Government. Title 17, U.S.C., §101 defines a US Government work as a work prepared by a military service member or employee of the US Government as part of that person's official duties. The views expressed in this article are those of the authors and do not necessarily reflect the official policy or position of the Department of the Navy, Department of Defense, or the US Government.

Abbott
WS.
1925
.
A method of computing the effectiveness of an insecticide
.
J Econ Entomol
18
:
265
267
.
ASTM [American Society for Testing and Materials]
.
2004
.
Standard E1620. Terminology relating to liquid particles and atomization. Annual Book of ASTM Standards
.
West Conshohocken, PA
:
ASTM International
.
Bartlett
MS.
1937
.
Properties of sufficiency and statistical tests
.
Proc R Statist Soc Ser A
160
:
268
282
.
Chadee
DD.
1985
.
An evaluation of malathion ULV spraying against caged and natural populations of Aedes aegypti in Trinidad, West Indies
.
Ser Entomol Med Parasitol
23
:
71
74
.
Chadee
DD.
2013
.
Resting behaviour of Aedes aegypti in Trinidad: with evidence for the re-introduction of indoor residual spraying (IRS) for dengue control
.
Parasit Vectors
6
:
255
.
Esu
E,
Lenhart
A,
Smith
L,
Horstick
O.
2010
.
Effectiveness of peridomestic space spraying with insecticide on dengue transmission; systematic review
.
Trop Med Intl Health
15
:
619
631
.
Farooq
M,
Corrado
JG,
Knapp
JA,
Xue
RD,
Smith
ML,
Briley
AKC,
Richardson
AG,
Cilek
J.
2018
.
Effect of travel speed on dispersion of Aqualuer 20-20 sprayed by a truck-mounted ultra-low–volume sprayer against caged Aedes aegypti
.
J Am Mosq Control Assoc
34
:
70
74
.
Farooq
M,
Fulcher
A,
Xue
RD,
Smith
ML,
Anderson
JL,
Richardson
AG,
Knapp
JA.
2017
.
Effect of nozzle orientation on dispersion of Aqualuer 20-20 sprayed by a truck mounted ultra-low volume sprayer against caged Aedes aegypti
.
J Am Mosq Control Assoc
33
:
209
214
.
Farooq
M,
Hoffmann
WC,
Fritz
BK,
Cote
N,
Walker
TW,
Smith
VL.
2016
.
Evaluation of spray droplet spectrum of sprayers used for vector control
.
Atomization Sprays
26
:
739
754
.
Farooq
M,
Hoffmann
WC,
Walker
TW,
Smith
VL,
Robinson
CA,
Dunford
JC,
Sutherland
IW.
2009
.
Samplers for evaluation and quantification of ultra-low volume space sprays
.
J Am Mosq Control Assoc
25
:
521
524
.
Hales
S,
Wet
ND,
Maindonald
J,
Woodward
A.
2002
.
Potential effect of population and climate changes on global distribution of dengue fever: an empirical model
.
Lancet
360
:
830
834
.
Harburguer
L,
Lucia
A,
Licastro
S,
Zerba
E,
Masuh
H.
2012
.
Field comparison of thermal and non-thermal ultra-low-volume applications using water and diesel as solvents for managing dengue vector, Aedes aegypti
.
Trop Med Int Health
17
:
1274
1280
.
Harwood
JF,
Farooq
M,
Richardson
AG,
Doud
CW,
Putnam
JL,
Szumlas
DE,
Richardson
JH.
2014
.
Exploring new thermal fog and ultra-low volume technologies to improve indoor control of the Dengue vector, Aedes aegypti (Diptera: Culicidae)
.
J Med Entomol
51
:
845
854
.
Heintze
C,
Garrido
MV,
Kroeger
A.
2007
.
What do community-based dengue control programmes achieve? A systematic review of published evaluations
.
T R Soc Trop Med H
101
:
317
325
.
Hoffmann
WC,
Walker
TW,
Fritz
BK,
Farooq
M,
Smith
VL,
Robinson
CA,
Lan
Y.
2012
.
Further evaluation of spray characterization of sprayers typically used in vector control
.
J Am Mosq Control Assoc
28
:
93
101
.
Jacobs
M.
2000
.
Dengue: emergence as a global public health problem and prospects for control
.
T R Soc Trop Med H
94
:
7
8
.
Kruskal
WH,
Wallis
WA.
1952
.
Use of ranks in one-criterion analysis of variance
.
J Am Statist Assoc
47
:
583
621
.
Mani
TR,
Arunachalam
N,
Rajendran
R,
Satyanarayana
K,
Dash
AP.
2005
.
Efficacy of thermal fog application of deltacide, a synergized mixture of pyrethroids, against Aedes aegypti, the vector of dengue
.
Trop Med Int Health
10
:
1298
1304
.
Manzanilla
FD,
Lopez
JI,
Marın
WB,
Jaimes
AM,
Leyva
JT,
Morales
FC,
Huerta
H,
Saide
PM,
Prokopec
GMV.
2017
.
Indoor resting behavior of Aedes aegypti (Diptera: Culicidae) in Acapulco, Mexico
.
J Med Entomol
54
:
501
504
.
Murray
NE,
Quam
MB,
Wilder-Smith
A.
2013
.
Epidemiology of dengue: past, present and future prospects
.
Clin Epidemiol
5
:
299
309
.
Perich
MJ,
Bunner
BL,
Tidwell
MA,
Williams
DC,
Mara
CD,
Carvalhe
T.
1992
.
Penetration of ultra-low volume applied insecticide into dwellings for dengue vector control
.
J Am Mosq Control Assoc
8
:
137
142
.
Perich
MJ,
Davila
G,
Turner
A,
Garcia
A,
Nelson
M.
2000
.
Behavior of resting Aedes aegypti (Culicidae: Diptera) and its relation to ultra-low volume adulticide efficacy in Panama City, Panama
.
J Med Entomol
37
:
541
546
.
Ponlawat
A,
Harwood
JF,
Putnam
JL,
Nitatsukprasert
C,
Pongsiri
A,
Kijchalao
U,
Linthicum
KJ,
Kline
DL,
Clark
GG,
Obenauer
PJ,
Doud
CW,
Mccardle
PW,
Richardson
AG,
Szumlas
DE,
Richardson
JH.
2017
.
Field evaluation of indoor thermal fog and ultra-low volume applications for control of Aedes aegypti in Thailand
.
J Am Mosq Control Assoc
33
:
116
127
.
Scheffe
H.
1959
.
The analysis of variance
.
New York
:
John Wiley and Sons
.
Smirnov
NV.
1939
.
On the estimation of the discrepancy between empirical curves of distribution for two independent samples
.
Bull Moscow Univ Intern Ser (Math)
2
:
3
16
.
Sudsom
N,
Techato
K,
Thammapalo
S,
Chongsuvivatwong
V,
Pengsakul
T.
2015
.
High resurgence of dengue vector populations after space spraying in an endemic urban area of Thailand: a cluster randomized controlled trial
.
Asian Pac J Trop Biomed
5
:
965
970
.
WHO [World Health Organization]
.
2007
.
Scientific Working Group on dengue: Meeting report, 1–5 October 2006
.
Geneva, Switzerland
:
World Health Organization
.
WHO [World Health Organization]
.
2012
.
Global strategy for dengue prevention and control 2012–2020
.
Geneva, Switzerland
:
World Health Organization
.

Author notes

1

Anastasia Mosquito Control District, 120 EOC Drive, St. Augustine, FL 32092.

2

US Navy Entomology Center of Excellence, Box 43 NAS JAX, Jacksonville, FL 32212.

3

Armed Forces Pest Management Board, Silver Spring, MD 20910.