The present study focused on investigating whether universal screwdriver kits cause less friction between the screwdriver and the abutment screw than original screwdrivers. For this purpose, 2 original screwdrivers (Straumann and BEGO) and a universal screwdriver kit (bredent) were investigated. On 1 implant per screwdriver, 26 abutments were properly attached one after the other with the corresponding abutment screws. After tightening the abutment screw, the force required to pull the screwdriver off the screw head was determined with a spring balance. For both manufacturers, greater pull-off forces were measured when using the original screwdrivers than when using the universal screwdriver. The pull-off force (mean ± SD) required for the Straumann original screwdriver was 3.7 ± 1.4 N, while that required for the universal screwdriver was 0.1 ± 0.1 N (P < .001). The pull-off force was 1.5 ± 1.5 N for the BEGO original screwdriver and 0.7 ± 0.9 N for the universal screwdriver (P = .19). Using original manufacturer-supplied screwdrivers could thus minimize the risk of the screwdriver slipping out of the screw head during dental treatment and being swallowed or aspirated by the patient.
Skip Nav Destination
Article navigation
October 2023
CLINICAL DENTAL IMPLANT SCIENCE RESEARCH|
February 13 2024
Comparing Original and Universal Screwdrivers and How They Affect Friction in the Screw Available to Purchase
Vasilios Alevizakos, DDS;
Vasilios Alevizakos, DDS
1Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Krems, Austria.
Search for other works by this author on:
Nadine Achilles, DDS;
Nadine Achilles, DDS
2Hannover Medical School, Department of Oral and Maxillofacial Surgery, Hannover, Germany.
Search for other works by this author on:
Björn Rahlf, DDS;
Björn Rahlf, DDS
2Hannover Medical School, Department of Oral and Maxillofacial Surgery, Hannover, Germany.
Search for other works by this author on:
Philipp Jehn, MD, DDS;
Philipp Jehn, MD, DDS
2Hannover Medical School, Department of Oral and Maxillofacial Surgery, Hannover, Germany.
Search for other works by this author on:
Constantin von See, DDS;
Constantin von See, DDS
1Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Krems, Austria.
Search for other works by this author on:
Marcus Schiller, DDS
Marcus Schiller, DDS
*
2Hannover Medical School, Department of Oral and Maxillofacial Surgery, Hannover, Germany.
*Corresponding author, e-mail: [email protected]
Search for other works by this author on:
J Oral Implantol (2023) 49 (5): 532–536.
Citation
Vasilios Alevizakos, Nadine Achilles, Björn Rahlf, Philipp Jehn, Constantin von See, Marcus Schiller; Comparing Original and Universal Screwdrivers and How They Affect Friction in the Screw. J Oral Implantol 1 October 2023; 49 (5): 532–536. doi: https://doi.org/10.1563/aaid-joi-D-20-00249
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your Institution
121
Views
Citing articles via
Retrospective Radiographic analysis of ridge augmentations using Titanium mesh and Titanium-reinforced polytetrafluoroethylene membranes
Lina Elnakka, DDS,MSD, Janina Golob Deeb, DMD, MS, Caroline K. Carrico, PhD, Aniket Jadhav, DDS, MDS, MSHA, Anusha Vaddi, BDS, MDS, George R. Deeb, DDS, MD, FACS
The Performance of PEKK versus Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: an in vitro Study
Zeynab Ahmed, DDS, Marc Joos, DDS, Roland Joos, PhD, Martin Rosentritt, PhD, Sebastian Kühl, DDS, Valentin Herber, DDS
Comparison of Subperiosteal Implant Designs Applied to Atrophic and Edentulous Mandible Under Traumatic Forces: 3D Finite Element Analysis
Ilgın Ari, Gülin Acar, İpek Dilara Baş, Emre Tosun
The Significance of Keratinized Mucosa on Implant Health: An Umbrella Review
Amirhossein Fathi, MSc, DDS, Sepideh Salehi, DDS, Farzad Kazemi, DDS, Shiva nayerain Jazi, DDS
The Effect of Cantilever Planning on Stress Distribution in Implant-Supported Prostheses
Sema Ateşalp İleri, MD, Neslihan Güntekin, MD, Reza Mohammadi