The purpose of this study was to examine the impact of abutment screw head sizes on preload stability when secured to a standard external hex implant under oblique compressive forces. Fifteen metal crowns were divided into 3 equal groups. The first group had 5 angulated cemented crowns connected to a 3-mm-tall straight hexagonal abutment with an external hex abutment screw. The second and third groups each had 5 straight cemented crowns attached to a tapered abutment with flat-slotted and internal hex abutment screws, respectively. Samples were subjected to a static cyclic load until failure. Kruskal-Wallis H, Dunn, and one-way analysis of variance with Tukey honestly significant difference tests were performed. Cemented straight crowns supported by an angled abutment connected to implants with flat-slotted and internal hex abutment screw heads failed at an average of 4.24 × 106 cycles ± 3.31 SD and 12.67 × 106 cycles ± 5.47 SD, respectively. Cemented angled crowns supported by a straight abutment connected to identical implants with an external hex abutment screw survived 18.02 × 106 cycles ± 4.49 SD. The periotest value rate of change increased at a higher rate in crowns supported by angled abutments compared with straight abutments (p < .05). No cement failure was observed. Under the experimental conditions, larger abutment screw head sizes demonstrated greater stability of the abutment-abutment screw joint interface. Based on the in vitro findings, no cement failure was observed between the cemented crown and abutment connection. Future research with standardized comparative setups and larger sample sizes is needed.
Skip Nav Destination
Article navigation
December 2024
CLINICAL DENTAL IMPLANT RESEARCH|
December 10 2024
A Biomechanical Comparative Analysis of Abutment Screw Head Designs on Preload Stability Under Oblique Compressive Forces: An In Vitro Pilot Study
Jan C. Kwan, MESc
Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal
Corresponding author, e-mail: [email protected]
Search for other works by this author on:
J Oral Implantol (2024) 50 (6): 617–625.
Citation
Jan C. Kwan; A Biomechanical Comparative Analysis of Abutment Screw Head Designs on Preload Stability Under Oblique Compressive Forces: An In Vitro Pilot Study. J Oral Implantol 1 December 2024; 50 (6): 617–625. doi: https://doi.org/10.1563/aaid-joi-D-24-00128
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your InstitutionCiting articles via
HISTOMORPHOMETRIC AND IMMUNOHISTOCHEMICAL EVALUATION OF BONE HEALING AROUND IMPLANTS PLACED USING PIEZOSURGERY VS CONVENTIONAL DRILLS: A SPLITMOUTH PILOT STUDY
Elisabetta Vignudelli, DDS MSc Phd, Alessando Cucchi, DDS MCli Phd, Alberto Righi, MD Phd, Tommaso Vercellotti, MD DDS, Giuseppe Corinaldesi, MD DDS MS, Fiorino Antonino, DDS MSc Phd
Open flap debridement protocol as a treatment of peri-implantitis: a 3-year follow-up case series
Líssya Tomaz da Costa Gonçalves, DDS, MSc, Fernanda Estevão de Campos Cunha, Dental Student, Alexandre Marques Paes da Silva, DDS, MSc, PhD, Glaucia Schuindt Teixeira Neves, DDS, MSc, Daniel Moraes Telles, DDS, MSc, PhD, Carlos Marcelo Figueredo DDS, MSc, PhD, Eduardo José Veras Lourenço, DDS, MSc, PhD, Mayla Kezy Silva Teixeira, DDS, MSc, PhD
Influence of gingival color and abutment material on the final color of peri-implant soft tissue: An in vitro analysis
Nazmiye Şen, DDS, PhD, Ibrahim Bulent Şermet, DDS, PhD
Full-arch implant-supported rehabilitation using reverse scan technique: A case report
Phuc Ngoc Nguyen, D.D.S., Ph.D., Lam Hung Tran, D.D.S., Ph.D., Viet Hoang, D.D.S.
Enhancing Digital Innovations in Maxillofacial Rehabilitation: Insights on Zygomatic Implant-Based Prosthetics
Carlos M. Ardila, Pradeep Kumar Yadalam