The o-rings in ball retained overdentures deteriorate with time and need replacement to restore the retentive quality. We evaluated retrospectively the mechanical properties of o-rings after 3 years in function in one and two-piece implant-supported overdentures. The o-rings were retrieved from one-piece (Myriad snap, Equinox-Straumann, 3.3 x 13mm) and two-piece (Neo Biotech, 3.3 x 13mm) implant-supported overdenture patients. A total of 16 pairs of matrices were tested for wear, type of damage and elasticity using Pin on Disc method, USB Digital Camera in 30x zoom and Universal Tensile Machine respectively. The statistical analysis for independent groups were done with the Mann-Whitney U test. Assessment of used O-rings showed 84% more wear in the two-piece system with an abrasive type of damage while 46% wear in the one-piece system with a compressive type of damage. The o-rings in one-piece system showed increase in elongation and maximum displacement to 2% and 7% respectively, while two-piece system showed decrease in elongation and maximum displacement by 13% and 6% respectively. In one-piece system, the loss of retention was more with slow wear rate and in two-piece system, the wear resistance of O-rings decreased due to increased stiffness. Further studies to evaluate the changes in O-ring with increased sample size and at interval 1 year will pave way for insight into the progressive changes in the mechanical properties of an O-ring.
Skip Nav Destination
Article navigation
Research Article|
March 09 2021
Evaluation of changes in mechanical properties of O-ring in one-piece and two-piece ball retained implant-supported overdentures: A three-year retrospective study.
Fathima Banu Raza
;
Fathima Banu Raza
Senior Lecturer, SRIHER
Search for other works by this author on:
Anand Kumar
Anand Kumar
Sri Ramachandra University
Prosthodontics
Porur
INDIA
Chennai
tamilnadu
600116
Sri Ramachandra University
Search for other works by this author on:
J Oral Implantol (2021)
Article history
Received:
April 26 2020
Revision Received:
August 19 2020
Revision Received:
October 08 2020
Accepted:
December 12 2020
Citation
Fathima Banu Raza, Anand Kumar; Evaluation of changes in mechanical properties of O-ring in one-piece and two-piece ball retained implant-supported overdentures: A three-year retrospective study.. J Oral Implantol 2021; doi: https://doi.org/10.1563/aaid-joi-D-20-00151
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Sign in via your Institution
Sign in via your Institution
0
Views
0
Citations
Citing articles via
Comparison of reliability of three resonance frequency analysis devices: An in vitro study
Burcu Diker, Nurettin Diker, Onjen Tak
A three-dimensional finite element analysis of resected mandibular bone to determine the most stable implant positions for a fixed prosthesis
Yasufumi Kosugi, Makoto Hirota, Naohito Tamai, Hikaru Takasu, Toshinori Iwai, Kenji Mitsudo
Variation in dental occlusal schemes two years after placement of single-implant posterior crowns. A preliminary study
Paula Prieto-Barrio, Laura Khoury-Ribas, Bernat Rovira-Lastra, Raul Ayuso-Montero, Jordi Martinez-Gomis
Comparison of positioning accuracy between two different implant systems using mucosa-supported surgical templates: a retrospective clinical study
Fudong Zhu, Mengyun Mao, Haihua Zhu, Yao Chen, Jia You, Haisong Pan
Digital Impression taking for Maxillary Full-Arch Restoration with Immediate Loading. A Case Report.
Jesús Peláez Rico, Jorge Cortés-Bretón Brinkmann, María Carrión Martín, Mabel Albanchez González, Celia Tobar Arribas, Verónica Rodríguez Alonso, Carlos López Suárez, María Jesús Suárez García