The aims of the present study are to measure and compare dental implant deviations with fully guided and pilot-drill-guided protocols using dynamic navigation systems in polyurethane models. The pilot-drill-guided group was determined to be the study group and included 12 implant applications. In this group, the pilot hole was drilled with navigation guidance, and the procedure was completed freehandedly. In the control group, all the drilling and implant placement steps were performed using the navigation system, and a total of 12 implants were placed. The pre- and postoperative images were compared to calculate the magnitude of implant deviation. The quantitative data of the two groups were compared using the independent-samples t-test and Mann-Whitney U-test. The analyses revealed that the length of the procedure significantly differed between the two groups (p < 0.001). The procedure duration was significantly shorter in the study group. The entry deviation values of the two groups were not significantly different (p = 0.079). The analysis revealed the apex deviation to be higher in the study group than in the control group (p = 0.003). However, the two-dimensional vertical apex deviation values of the implants were not significantly different between groups (p = 0.068). Angular deviation was determined to be significantly higher in the study group (p < 0.001). In the present study, all implants were successfully placed in the models using a dynamic navigation system. The results of this study may be useful for future clinical studies.
Skip Nav Destination
Article navigation
Research Article|
December 26 2021
Comparison of the accuracy of pilot-drill-guided and fully guided implant surgery with dynamic navigation. In vitro model study
Umut Demetoglu;
Umut Demetoglu
Erciyes University
Oral and Maxillofacial Surgery
Erciyes University Dentistry Faculity Melikgazi
TURKEY
Kayseri
Kayseri
38000
Erciyes University
Search for other works by this author on:
J Oral Implantol (2021)
Article history
Received:
October 08 2020
Revision Received:
February 07 2021
Revision Received:
May 30 2021
Accepted:
October 25 2021
Citation
Umut Demetoglu, Suheyb Bilge, Senol Aslan, Hasan Onur Simsek; Comparison of the accuracy of pilot-drill-guided and fully guided implant surgery with dynamic navigation. In vitro model study. J Oral Implantol 2021; doi: https://doi.org/10.1563/aaid-joi-D-20-00383
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your Institution
59
Views
1
Crossref
Citing articles via
Mucosal Coverage of Deeply Protruded Implant in The Maxillary Sinus: A Case Report
Won-Bae Park, DMD, PhD, Joshua Lin, DDS, Wonhee Park, DDS, PhD, Ji-Young Han, DMD,PhD, Philip Kang, DDS
Technique to Protect the Palatal Donor Area After Taking a Free Gingival Graft: Patchwork Technique
Martín Laguna-Martos, DDS, Rocío Cascos, DDS, Óscar Iglesias-Velázquez, DDS, Miguel Gómez-Polo, DDS, PhD, Solange Vasquez-Ramos, DDS, MSD, Adriana Castro-Calderón, DDS
Management of dental implant components following abutment screw loosening: A case report
Chandur Wadhwani, BDS, MSD, Shi Yin, DDS MS, Scott Froum, DDS CTN, Hanson Fong, PhD, Kwok-Hung Chung, DDS MS PhD
Application of Fixed Implant Superstructures following Multi- Stage Maxillary Reconstruction in Osteosarcoma Patients: A case report
Sho Miyamoto, DDS PhD, Hironari Dehari, DDS PhD, Takaaki Tokura, DDS PhD, Takanori Sasaki, DDS PhD, Tomohiro Igarashi, DDS PhD, Shunichi Shimura, DDS PhD, Koyo Nishiyama, DDS PhD, Kenya Mori, DDS, Takatoshi Yotsuyanagi, MD PhD, Akihiro Miyazaki, DDS PhD
Stress Distribution Analysis in Bone Adjacent to Implant in Various Abutment-Implant Connection Designs Using Finite Element Analysis
Ehsan Ghasemi, MSc, Amirhossein Fathi, DDS, MSc, Daryoush Mohammadi, DDs, Sepideh Salehi, DDs