Accuracy of completely edentulous arch scanning with implant scan bodies has not been completely validated for intraoral scanners. For desktop laboratory scanners validations were found in the literature. The aim of this in vitro study was to compare the dimensional accuracy of scanning with splinted and unsplinted scan bodies on a completely edentulous maxillary arch with 6 implants. A maxillary edentulous master cast with 6 implants was used as control for all implant level impressions. 6 implants were digitally planned and placed at different angulation of 0, 0 17° and 30°. A contact coordinate measuring machine (CMM) was used to generate baseline linear measurements of the master cast. Four test groups included: 2 intraoral scanners Trios (3shape, Copenhagen, Denmark) and True Definition (3M ESPE, St Paul, MN), one industrial scanner Atos (Core optical 3D scanner) and one conventional impression group scanned with laboratory scanner Dental Wings 7 Series. Each scan recording was made with splinted and unsplinted scan bodies. Digital datasets of all measurements were compared with the CMM baseline values using PolyWorks® InnovMetric Software in order to assess the linear and angular deviations and determine the accuracy of complete arch digital impression. Factorial ANOVA showed significant effect with splinting, scanner type, inter-implant distance and implant angulation for linear deviations. Splinted scan bodies revealed elevated linear and angular deviation values for all scanners with significantly highest deviations for True Definition scanner. Significant correlation was found between inter-implant distance and linear deviation (r =0.45, P =<0.001) with increased linear deviations among all scanners, regardless of splinting. ( P <0.05). Significant effect on accuracy was seen for angular deviation with splinting, scanner type and implant angulation; significant difference was found between 0° and 30° implant angulation ( P =0.035) with more deviation with 30° implant angulation. The accuracy of the complete arch implant digital impression using splinted scan bodies was significantly reduced for measurements that crossed the arch midline. The digital impression technique using a broad splint design to connect scan bodies was not found to improve the scan accuracy for intraoral scanners.
Skip Nav Destination
Article navigation
Research Article|
July 11 2022
Scanning accuracy with splinted and unsplinted implant scan bodies for the edentulous arch at implant level: an in vitro study
ANTOANELA GARBACEA;
ANTOANELA GARBACEA
Loma Linda University School of Dentistry
Assistant Professor
Prosthodontics and Implant Dentistry
11092 Anderson street
UNITED STATES
Loma Linda
CA
92350
9092068096Assistant Professor, Advanced Specialty Education Program in Prosthodontics and Implant
Search for other works by this author on:
Ali F Alqahtani;
Ali F Alqahtani
Faculty, Department of Periodontics and Community Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Search for other works by this author on:
Brian Goodacre;
Brian Goodacre
Assistant Professor, School of Dentistry, Loma Linda University, Loma Linda, California, USA
Search for other works by this author on:
Abdulaziz Alhelal;
Abdulaziz Alhelal
Assistant Professor, Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
Search for other works by this author on:
Jaime Lozada;
Jaime Lozada
Professor and Director, Advanced Education Program in Implant Dentistry, School of Dentistry, Loma Linda University, Loma Linda, California, USA.
Search for other works by this author on:
Mathew T Kattadiyil
Mathew T Kattadiyil
fProfessor and Director, Advanced Specialty Education Program in Prosthodontics, School of Dentistry, Loma Linda University, Loma Linda, California, USA
Search for other works by this author on:
J Oral Implantol (2022)
Article history
Received:
November 09 2021
Revision Received:
April 05 2022
Accepted:
June 08 2022
Citation
ANTOANELA GARBACEA, Ali F Alqahtani, Brian Goodacre, Abdulaziz Alhelal, Jaime Lozada, Mathew T Kattadiyil; Scanning accuracy with splinted and unsplinted implant scan bodies for the edentulous arch at implant level: an in vitro study. J Oral Implantol 2022; doi: https://doi.org/10.1563/aaid-joi-D-21-00293
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Sign in via your Institution
Sign in via your Institution
138
Views
2
Crossref
Citing articles via
Von Mises equivalent stresses developed in fixed partial denture infrastructures on implants according to changes in their prosthetic materials
Marcelo Bighetti Toniollo, MSc, PhD, Kalyta Esteves Martins dos Reis, Graduate student, Silvio Pedro da Silva Sakamoto, DDs, Andrea Sayuri Silveira Dias Terada, MSc, PhD, Luiz Renato Paranhos, MSc, PhD, Ana Paula Macedo, MSc, PhD, Renato Canevari Dutra da Silva, MSc, PhD, Pedro Henrique Justino Oliveira Limirio, MSc, PhD
Influence of Gingival Color and Abutment Material on the Final Color of Peri-Implant Soft Tissue: An In Vitro Analysis
Nazmiye Şen, DDS, PhD, Ibrahim Bulent Şermet, DDS, PhD
Full-Arch Implant-Supported Rehabilitation Using Reverse Scan Technique: A Case Report
Phuc Ngoc Nguyen, DDS, PhD, Lam Hung Tran, DDS, PhD, Viet Hoang, DDS
Proper Diagnosis of the “Terminal Dentition”
Bill Anderson, DDS, John D. Erdeljac, DDS, Shankar Iyer, DDS, Edgard El Chaar, DDS, MS, EMBA/MS, James L. Rutkowski, DMD, PhD
Open Flap Debridement Protocol as a Treatment of Peri-Implantitis: A 3-Year Follow-up Case Series
Líssya Tomaz da Costa Gonçalves, DDS, MSc, Fernanda Estevão de Campos Cunha, Alexandre Marques Paes da Silva, DDS, MSc, PhD, Glaucia Schuindt Teixeira Neves, DDS, MSc, PhD, Daniel de Moraes Telles, DDS, MSc, PhD, Carlos Marcelo Figueredo, DDS, MSc, PhD, Eduardo José Veras Lourenço, DDS, MSc, PhD, Mayla Kezy Silva Teixeira, DDS, MSc, PhD