The clinical application of a 4-step technique for achieving the passive fit of an implant-supported cast bar or framework is reported. Implant-level transfers were attached, splinted intraorally with pattern resin, picked up in an open-tray elastomeric impression, and used to fabricate a working cast containing implant analogs. A light-cured template was used to verify master cast accuracy. A ceramometal fixed partial denture restoration was fabricated on the working cast with a preliminary try-in of the cast metal framework. A passive prosthesis fit was achieved. Failure to create an accurate working cast can distort the intended fit of a cast framework on the abutments in the patient's mouth. Optimal positioning of the implant analog in the master cast depends on (1) the transfer technique and (2) the ability of the system to maintain precise rotational orientation of the transfer components. The splinted transfer technique developed 20 years ago has sometimes been effective in improving the accuracy of framework fit with external hexagon implant-abutment connections, but it has not been documented with newer implant-abutment connections. Techniques for reestablishing master cast accuracy and correcting the superstructure are presented. The use of the presented technique resulted in a passive-fitting framework.

The importance of achieving a passive fit between a cast metal framework or bar and the supporting implant abut-ments is frequently cited in the dental literature as essential for the long-term success of an implant-supported restoration.1–3 The “passive fit” concept, however, remains controversial and only partially understood.2 At present, there is no clear consensus as to what constitutes a passive fit, although failure to eliminate distortion between the cast framework and the implant abutments has been suggested as one reason for biologic complications or delayed component failure.2,4–15 If distortion is defined as the relative movement of a single point or a group of points away from some originally specified reference position such that permanent deformation is apparent,16–18 then cast superstructures that deviate from their intended relationship with the implant abutments may be considered as having failed to achieve a passive fit.2 

Published data on the long-term clinical effects of nonpassive fitting or distorted frameworks are conflicting and still open to question. Some clinical studies utilizing both animal and human models have suggested that no biologic or mechanical complications may arise from a nonpassive-fitting implant framework.2 Other reports in the dental literature state that, if a malfitting superstructure exerts any tension or stress on the supporting abutments, occlusal loading could result in a host of prosthodontic complications (eg, component joint opening,4 repeated screw loosening,5,6 component stress fractures5–7) and adverse tissue reactions (eg, ischemia, microfractures of the peri-implant bone,7 pain, tenderness, marginal bone recession, loss of osseointegration8,9).1 These problems can reportedly intensify in partially edentulous jaws, where the implant-abutment interface and abutment retention screw are subjected to greater lateral bending loads, tipping, and elongation than are bilaterally splinted implants in edentulous jaws.1,9–13 Construction-related distortion also tends to increase in proportion to the length of the cast bar or framework span14 and can be exacerbated by the nonparallel placement of dental implants.1 However, the ability to achieve a distortion-free fit is only relative because of a variety of variables, such as flexure of the mandible, differences in machining tolerances among components, and distortion factors that can arise during fabrication of the superstructure.1–3 

To correct the abutment-superstructure relationship when gross misfit occurs, cutting the framework or bar and reconnecting the segments by soldering or electrowelding have been advocated, but both techniques can further distort the fit.1,19–20 Soldered joints are also inherently weaker than solid, 1-piece castings and may be subject to fracture under prolonged occlusal loading.1 To avoid the need for such corrections and remakes, some clinicians have focused on improving the initial fit of cast superstructures.21 Factors that can influence the accuracy of the initial bar or framework fit include the material22,23 and technique21–23 used for impressioning and the design21–23 and positional stability21,23–24 of the transfer posts. Air entrapment within the impression material and incomplete seating of the transfer posts can also negatively affect master cast accuracy.22 

Splinting impression posts together with autopolymerizing acrylic,25 light-cured resin (Triad, Dentsply, York, Pa),26–29 and various other materials before pick-up in a custom impression tray was first introduced nearly 20 years ago to improve master cast accuracy for implants with external hexagon connections. This was possible, in part, because of a minute void that existed at the implant-abutment interface, which helped ensure that the abutment would fully seat on the implant.30 The interfacial void also facilitated the ability to pick up the post in a transfer impression. Before the fixation screw was tightened, the interfacial void enabled the abutment to be rotated back and forth horizontally from 4° to 6.7° in some implant systems, depending on the range of machining tolerances set by the manufacturer.30–34 After screw tightening, occlusal loading could cause rotational slippage or micromovement of the abutment within the range of the interfacial void.9,10,30,31,35–37 Such rotational micromovements, as well as abutment tilting from nonaxial forces and occlusal stresses directed at the abutment fixation screw, have been reported to destabilize the implant-abutment connection and cause screw loosening.30,34,38,39 

The design, precision, and strength of the implant-abutment interface help reduce reliance on the fixation screw to maintain joint stability; thus, it has a direct bearing on the long-term stability of the restoration.13–14 To address the problem of screw loosening, some implant manufacturers have developed newer implant-abutment connections with narrower manufacturing tolerances and alternative interface designs (Table 1). Compared with the original external hexagon connection, many of the newer connections achieve more intimate contact between the mating components, which serves to minimize14 or eliminate12–13 rotational movements by the abutment. The narrower interfacial voids between the mated surfaces of the newer implant-abutment assemblies would necessitate that multiple implants be relatively parallel with each other to create a common path of draw for direct pick-up by transfer impressions. In addition, there would need to be sufficient intraoral vertical access to disengage the mated transfers from the implants and retrieve the impression from the patient's mouth.

Table 1

Examples of newer implant-abutment connections

Examples of newer implant-abutment connections
Examples of newer implant-abutment connections

This paper presents a case that successfully utilized the splinted transfer technique and other safeguards to ensure master cast accuracy for implants with an alternative implant-abutment connection, and it proposes a 4-step technique for achieving similar results with most current implant systems.

Patient evaluation

A 61-year-old Caucasian male presented in a private dental practice for rehabilitation of an edentulous maxillary jaw through implant prosthodontics. One year earlier, his lower posterior jaw had been restored with 6 dental implants (Figure 1) (Spline Twist MTX, Zimmer Dental Inc, Carlsbad, Calif), and the upper jaw was restored with an immediate full denture after extraction of all residual periodontally hopeless teeth. The improvement in the mandibular fixed restoration was so marked compared with the maxillary removable denture that the patient requested a comparable restoration for the maxillary jaw.

Figure 1.

The patient presented with an implant-supported bilateral posterior reconstruction (6 Spline implants) that was completed the previous year and with a full maxillary denture

Figure 1.

The patient presented with an implant-supported bilateral posterior reconstruction (6 Spline implants) that was completed the previous year and with a full maxillary denture

Close modal

Clinical and radiographic examinations were conducted. An updated health history was reviewed to evaluate the patient's present health condition and to rule out diseases or other factors that would contraindicate dental implant therapy. A diagnostic workup was performed to evaluate the volume and location of available bone, the esthetic and functional needs of the case, and how to best address the desires of the patient. Jaw relationships, available occlusal dimensions, proposed implant positions, crown-root ratios, and potential complications were evaluated on a mounted study cast. A surgical template to guide implant placement relative to the proposed prosthesis was fabricated from the prosthetic wax-up. After thoroughly discussing all treatment options and alterna-tives, a signed informed consent was obtained, and the patient was scheduled for surgery.

Implant selection

The implant used in this case was a self-tapping screw with a microtextured surface (Spline Twist MTX). It featured a prosthetic platform with 6 projections and slots that interdigitated with the abutment. This design was selected based on the documented advantages of using a roughened surface25–36 and a stable prosthetic connection.14,37 

Surgical and preliminary prosthodontic procedures

An interocclusal record was made immediately before surgery. The patient was anesthetized by local infiltration and prepared for surgery. Primary (midcrestal) and secondary (releasing) incisions were made with a scalpel (#15 Bard-Parker, BD Medical Systems, Franklin Lakes, NJ), and a full-thickness, mucoperiosteal flap was carefully elevated to expose the ridge. Because the nonparallel placement of dental implants can complicate the fit of a cast superstructure, a surgical template and drill-guide pins were used to carefully prepare osteotomies that were mutually parallel and optimally positioned to support the prosthesis. Sequential cutting was performed with internally irrigated drills by using standard procedures, and 12 implants were placed according to the manufacturer's protocol.

After removing the fixture mounts from each of the implants, impression posts were attached and an open-tray transfer impression was made to fabricate a preliminary working cast. The transfers were replaced with surgical cover screws, and primary closure was achieved with 4-0 coated vicryl sutures (Ethicon/Johnson and Johnson, Somerville, NJ). One week later, the sutures were removed, and the patient resumed wearing his relieved and softlined (Coe-Soft, GC America Inc, Alsip, Ill) denture until the uncovering appointment.

During the submerged healing period, transitional abutments and a second provisional prosthesis were prepared for the primary implants in the dental laboratory. Four months after placement, the implants were surgically exposed. Clinical osseointegration was confirmed radiographically and by manual testing. The sterilized transitional abutments were attached to the implants, the soft tissues were sutured with 4-0 coated vicryl sutures (Ethicon/Johnson and Johnson) around them, and the provisional fixed prosthesis was cemented onto the abutments. The sutures were removed after 1 week, and the second provisional prosthesis was allowed to function for 30 days to allow for complete soft-tissue maturation.

Restorative procedures

Before commencing restorative procedures, open-tray transfers were attached to the preliminary working cast and a custom impression tray with open occlusal access was fabricated for use with implant-level direct transfers (Figure 2). The finished custom tray was removed and a 4-step technique was implemented to ensure the passive fit of the final cast framework (Table 2).

Figures 2–6. Figure 2. During a postuncovering period of provisionalization, direct transfers were attached to a preliminary working cast, and a custom open tray was fabricated. Figure 3. Open-tray transfers on the preliminary working cast were splinted with GC pattern resin, and then each connection was carefully severed between the transfers with a fine saw blade. Figure 4. The open-tray transfers were attached to the implants, and the connections were luted together intraorally with GC pattern resin. Cotton was used to block out the transfer tops. Figure 5. The custom tray was tried into the mouth to verify that the transfers penetrated the occlusal openings without hindrance. Figure 6. The splinted transfers were picked up in an elastomeric impression

Figures 2–6. Figure 2. During a postuncovering period of provisionalization, direct transfers were attached to a preliminary working cast, and a custom open tray was fabricated. Figure 3. Open-tray transfers on the preliminary working cast were splinted with GC pattern resin, and then each connection was carefully severed between the transfers with a fine saw blade. Figure 4. The open-tray transfers were attached to the implants, and the connections were luted together intraorally with GC pattern resin. Cotton was used to block out the transfer tops. Figure 5. The custom tray was tried into the mouth to verify that the transfers penetrated the occlusal openings without hindrance. Figure 6. The splinted transfers were picked up in an elastomeric impression

Close modal
Table 2

A 4-step technique for achieving a passive bar or framework fit

A 4-step technique for achieving a passive bar or framework fit
A 4-step technique for achieving a passive bar or framework fit

Step 1: Splinted Transfer Technique

The transfers were splinted together on the master cast with GC Pattern Resin (GC Corporation, Tokyo, Japan) (Figure 3). A fine saw blade was used to carefully sever the connection between each abutment. The patient was appointed and the provisional prosthesis was removed. After attaching the transfers to the implants in the patient's mouth, each severed connection was reluted intraorally with GC Pattern Resin, polymer, and monomer by a “salt and pepper” technique, and the tops of the transfers were blocked out with cotton (Figure 4).

The custom tray was tried into the patient's mouth to verify that the screws of the splinted impression posts penetrated through its occlusal openings without hindrance (Figure 5). A full-arch, open-tray impression was made with light- and heavy-body elastomeric materials (Permadyne, 3M Espe, St Paul, Minn) (Figure 6). After the material set, the screws were removed through the occlusal openings in the custom tray, and the splinted impression posts were carefully removed from the patient's mouth inside the impression. Implant analogs were attached to the embedded posts, and the impression was poured in soft-tissue replica material (Coe-Soft) and dental stone (VelMix Stone, Kerr, Orange, Calif). After the definitive working cast was separated, the impression posts were removed.

Step 2: Verifying Master Cast Accuracy

At this stage, it was necessary to determine if the positioning of the implant analogs in the master cast was congruent with the implants in the patient's mouth to avoid a non–passive-fitting framework. Ford1 and Ford and MacLarty40 developed a simple procedure for verifying the accuracy of a master cast by using an Accuracy Verification Template (AVT) (Table 3) and for reestablishing master cast accuracy in the event of a discrepancy (Table 4). The AVT is a light-cured framework fabricated on the master cast and transferred to the implants in the patient's mouth to verify the accuracy of the cast. If the framework remains intact, the working cast is deemed accurate and restorative procedures can continue. In the present case, verification showed that the splinted transfer technique maintained precise component locations and that an accurate master cast had been produced. The provisional prosthesis was reattached and the patient was dismissed until the definitive prosthesis delivery appointment.

Table 3

Accuracy Verification Template (AVT) for verifying master cast accuracy

Accuracy Verification Template (AVT) for verifying master cast accuracy
Accuracy Verification Template (AVT) for verifying master cast accuracy
Table 4

Ford's1 and Ford and MacLarty's40 technique for reestablishing master cast accuracy

Ford's1 and Ford and MacLarty's40 technique for reestablishing master cast accuracy
Ford's1 and Ford and MacLarty's40 technique for reestablishing master cast accuracy

Step 3: Reestablishing Master Cast Accuracy

If the AVT distorts or breaks when it is attached to the implants in the patient's mouth because of an inaccurate working cast, the framework segments are severed and reluted intraorally. The corrected AVT is then removed from the patient's mouth. A new master cast may be fabricated with the appropriate transfers. If only 1 implant analog is malpositioned in the original master cast, the implant analog is extracted from the dental stone and attached to the appropriate location on the AVT. The void in the cast is filled with dental stone so that the implant analog attached to the AVT will be correctly repositioned in the cast after the AVT is attached to the remaining implant analogs. If the AVT distorts or breaks as a result of a rotational micromovement problem inherent in the implant system, the definitive abutments would have to be retorqued into place, temporized, and not tampered with again.

In the present case, the definitive abutments were attached to the working cast, prepared (Figure 7), and coated with a separating medium (Die Lube, GW Smith and Sons Inc, Dayton, Ohio). A framework pattern was created directly on the prepared abutments and cast according to conventional laboratory procedures. The patient was then appointed for a try-in of the cast framework (Figure 8) to check for accuracy before porcelain was applied. The provisional prosthesis was removed, the definitive abutments were attached to the implants, and the framework was attached to the abutments with fixation screws. Clinical and radiographic examinations (Figure 9) revealed no evidence of gaps, tension, or stress among any of the components. When the fixation screws were removed, downward pressure on the bar did not elicit any rocking or movement by the cast superstructure, which continued to rest passively on the abutments. After verifying that a passive fit had been achieved, the provisional prosthesis was replaced and the patient was dismissed until the definitive prosthesis delivery appointment. The 6 posterior units used engaging shouldered abutments; the 6 anterior units used modified straight abutments that required no screws.

Figures 7–11. Figure 7. A definitive working cast with soft-tissue replica was fabricated. The definitive abutments were attached, prepared, and used as dies for fabricating the framework pattern. Figure 8. The cast framework was tried in to verify that a passive fit was achieved. Figure 9. No gaps were radiographically visible between the cast superstructure and the implant abutments. Figure 10. Porcelain was applied to the cast framework according to standard laboratory procedures. Figure 11. The definitive prosthesis provided natural-looking esthetics

Figures 7–11. Figure 7. A definitive working cast with soft-tissue replica was fabricated. The definitive abutments were attached, prepared, and used as dies for fabricating the framework pattern. Figure 8. The cast framework was tried in to verify that a passive fit was achieved. Figure 9. No gaps were radiographically visible between the cast superstructure and the implant abutments. Figure 10. Porcelain was applied to the cast framework according to standard laboratory procedures. Figure 11. The definitive prosthesis provided natural-looking esthetics

Close modal

Step 4: Establish a Passive Superstructure Fit

If a passive fit has not been achieved, Ford's1 Heat-Activated Solderless Passivation (HASP) technique can be used to achieve a passive fit without soldering or electrowelding (Table 5). Once the accuracy of the master cast has been verified (Tables 3 and 4), implant or abutment analogs (depending on the system) are attached to the AVT, and a soldering jig is fabricated with soldering investment material. After the material hardens, the malfitting cast superstructure is secured to the embedded components with fixation screws. Care is taken to ensure that the improperly fitting interface is completely closed on each abutment or implant analog by using all force necessary to close the gap. Heat sink material (Hot-Stop Heat Protection Gel, Renfert GmbH, Hilzingen, Germany) is applied as a protectant to all sections of the superstructure that are not to be altered. A laboratory torch is used to heat the exposed portion of the superstructure that would normally be cut and soldered to correct a joint imperfection until it turns cherry red.1 After each imperfect joint has been heated accordingly, the superstructure is allowed to bench-cool. It is then removed from the jig and tried in the patient's mouth to verify that a passive fit has been achieved.

Table 5

Ford's1 and Ford and MacLarty's40 Heat-Activated Solderless Passivation technique for correcting the fit of a cast bar or framework

Ford's1 and Ford and MacLarty's40 Heat-Activated Solderless Passivation technique for correcting the fit of a cast bar or framework
Ford's1 and Ford and MacLarty's40 Heat-Activated Solderless Passivation technique for correcting the fit of a cast bar or framework

In this case, the framework fit passively (Figure 9), and porcelain was applied and finished according to conventional procedures for ceramometal restorations (Figure 10) by the dental laboratory. At the delivery appointment, the definitive prosthesis was attached to the implants (Figure 11). Occlusion was verified and final adjustments were made. Postrestoration radiographs revealed no gaps between any of the mated components. Oral hygiene instructions were reviewed, and the patient was dismissed.

Sophisticated strategies and me-ticulous and accurate prostho-dontic procedures are still required to achieve a passive fit with an implant-supported bar or framework.3 Potential limitations to fabricating a passive-fitting superstructure include (1) failure by the clinician to successfully make a precise transfer and (2) failure by the implant system to maintain rotational accuracy. Newer abutment connections, such as the Spline interface used in the present study, and the splinted transfer technique can mitigate these problems and help ensure the accuracy and passivity of the final restoration.

Important considerations in abutment selection include the occlusal plane of the proposed restoration, variations in the heights of the peri-implant sulci, depths of implant placement, and contours of the residual ridge. To adequately treat a case, the clinician needs to have an assortment of abutment heights and contours available at the abutment-placement appointment. In fabricating the definitive prosthesis, impressions of prepared abutments in the mouth often cannot record the intended margin of the restoration. The splinted, implant-level transfer technique can greatly simplify decisions for dentists by allowing the dental laboratory to select or fabricate the ideal abutments for the case. Abutments for multiple-unit splinted cases can be custom fabricated, or stock abutments can be modified in the laboratory with exact tissue relationships on the working cast with a soft-tissue replica. The technique eliminates additional procedures that can introduce errors into the framework fabrication process, thereby shortening chair time and helping ensure an optimum fit of the casting.

When a custom tray is fabricated for the case, additional time can be saved if indirect transfers are attached to the preliminary working cast and luted together with light-cure resin material. The connection should be cut with a fine saw blade and then reluted intraorally before the pick-up impression. Because of the shortened overall treatment time, provisionalization of the case is not necessary unless it is desired for progressive loading or patient requirements.

In this case, a full-arch working cast containing analogs of the implants in the patient's mouth was fabricated through a splinted transfer technique, then it was used to prepare abutments and wax multiple-span framework patterns. Four important steps were discussed (Table 2), which can be used to ensure the fabrication of a passive-fitting cast bar or framework. Newer implant-abutment connections have improved screw stability, yet they still provide sufficient flexibility to use the splinted transfer technique. This step proved to be highly successful in establishing initial master cast accuracy, which was easily verified by the AVT technique (Tables 3 and 4). Despite this high level of accuracy, try-in of the cast framework was a responsible step that afforded an excellent opportunity to evaluate the fit before applying porcelain. Had misfit occurred, it could have been easily addressed at that time by the HASP technique (Table 5). Porcelain was then applied to the framework according to routine laboratory procedures, and the definitive prosthesis was delivered to the patient with an excellent passive fit, as determined by clinical and radiographical evaluations.

On a clinical level, the procedures described in this paper have been successfully used throughout the United States with excellent results.1 Further research is needed into new ways of ensuring the passive fit of implant-supported superstructures.

Utilization of the splinted impression technique, an AVT, the technique for reestablishing master cast accuracy, and the HASP technique with Spline implant connections can eliminate many of the problems associated with the fit and long-term stability of cast bars and frameworks for implant-supported restorations.

The author thanks Dr Louis Clarizio for placement of the Spline implants; Michael Desjardins, CDT, for the laboratory work; Zimmer Dental Inc for partial funding of the Spline components; and Robert Riley, CDT, and Michael M. Warner, MA, for assistance.

1
Ford
,
T. G.
The heat-activated solderless passivation (HASP) technique for correcting nonpassive-fitting bars without soldering.
Implant Dent
2002
.
12
:
11
17
.
2
Wee
,
A. G.
,
S. A.
Aquilino
, and
R. L.
Schneider
.
Strategies to achieve fit in implant prosthodontics: a review of the literature.
Int J Prosthodont
1999
.
12
:
167
178
.
3
Romero
,
G. G.
,
R.
Engelmeier
,
J. M.
Powers
, and
A. A.
Canterbury
.
Accuracy of three corrective techniques for implant bar fabrication.
J Prosthet Dent
2000
.
84
:
602
607
.
4
Fusayama
,
T.
,
S.
Wakumoto
, and
H.
Hosada
.
Accuracy of fixed partial dentures made by various soldering techniques and one-piece castings.
J Prosthet Dent
1964
.
14
:
334
342
.
5
Kan
,
J. Y. K.
,
K.
Rungcharassaeng
,
K.
Bohsali
,
C. J.
Goodacre
, and
B. R.
Lang
.
Clinical methods for evaluating implant framework fit.
J Prosthet Dent
1999
.
81
:
7
13
.
6
Gunne
,
J.
,
T.
Jemt
, and
B.
Linden
.
Implant treatment in partially edentulous patients: a report on prostheses after 3 years.
Int J Prosthodont
1994
.
7
:
143
148
.
7
Heldén
,
L. B.
and
T.
Dérand
.
Description and evaluation of a simplified method to achieve passive fit between cast titanium frameworks and implants.
Int J Oral Maxillofac Implants
1998
.
13
:
190
196
.
8
Kallus
,
T.
and
C.
Bessing
.
Loose gold screws frequently occur in full arch fixed prostheses supported by osseointegrated implants after 5 years.
Int J Oral Maxillofac Implants
1994
.
9
:
169
178
.
9
Yanase
,
R. T.
,
P. P.
Binon
,
T.
Jemt
,
H. J.
Gulbransen
, and
S.
Parel
.
Current issue forum. How do you test a cast framework for a full arch fixed implant supported prosthesis?
Int J Oral Maxillofac Implants
1994
.
9
:
471
474
.
10
Binon
,
P. P.
Implants and components: entering the new millennium.
Int Oral Maxillofac Implants
2000
.
15
:
76
94
.
11
Nicholls
,
J. I.
and
C. H-J.
Basten
.
A comparison of three mechanical properties of four implant designs.
Postgrad Dent
1995
.
2
:
4
12
.
12
Binon
,
P. P.
The evolution and evaluation of two interference-fit implant interfaces.
Postgrad Dent
1996
.
3
:
3
13
.
13
Binon
,
P. P.
The Spline implant: design, engineering, and evaluation.
Int J Prosthodont
1996
.
9
:
419
433
.
14
Riedy
,
S. F.
,
B. R.
Lang
, and
B. E.
Lang
.
Fit of implant frameworks fabricated by different techniques.
J Prosthet Dent
1997
.
78
:
596
604
.
15
Kallus
,
T.
and
C.
Bessing
.
Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years.
Int J Oral Maxillofac Implants
1994
.
9
:
169
178
.
16
Nicholls
,
J. I.
The measurement of distortion: theoretical considerations.
J Prosthet Dent
1977
.
37
:
578
586
.
17
Nicholls
,
J. I.
The measurement of distortion: mathematical considerations.
J Prosthet Dent
1978
.
39
:
339
343
.
18
Nicholls
,
J. I.
The measurement of distortion: concluding remarks.
J Prosthet Dent
1980
.
43
:
218
223
.
19
Zoidis
,
P. C.
,
S.
Winkler
, and
N. K.
Karellos
.
The effect of soldering electrowelding, and cast-to procedures on the accuracy of fit of cast implant bars.
Implant Dent
1996
.
5
:
163
168
.
20
Thoupos
,
G. A.
,
C. S.
Zouras
,
S.
Winkler
, and
V. G.
Roussos
.
Connecting implant framework segments.
Implant Dent
1995
.
4
:
97
99
.
21
Phillips
,
K. M.
,
J. I.
Nicholls
,
T.
Ma
, and
J.
Rubinstein
.
The accuracy of three implant impression techniques: a three-dimensional analysis.
Int J Oral Maxillofac Implants
1994
.
9
:
533
540
.
22
Spector
,
M. R.
,
T. E.
Donovan
, and
J. I.
Nicholls
.
An evaluation of impression techniques for osseointegrated implants.
J Prosthet Dent
1990
.
63
:
444
447
.
23
Assif
,
D.
,
A.
Fenton
,
G.
Zarb
, and
A.
Schmitt
.
Comparative accuracy of implant impression procedures.
Int J Periodont Restor Dent
1992
.
12
:
113
121
.
24
Humphries
,
R. M.
,
P.
Yaman
, and
T. J.
Bloem
.
The accuracy of implant master casts constructed from transfer impressions.
Int J Oral Maxillofac Implants
1990
.
5
:
331
336
.
25
Ericsson
,
I.
,
C. B.
Johansson
,
H.
Bystedt
, and
M. R.
Norton
.
A histomorphometric evaluation of bone-to-implant contact on machined-prepared and roughened titanium dental implants. A pilot study in the dog.
Clin Oral Implant Res
1994
.
5
:
202
206
.
26
Buser
,
D.
,
R. K.
Schenk
,
J. P.
Fiorellini
,
C. H.
Fox
, and
H.
Stich
.
Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.
J Biomed Mater Res
1991
.
25
:
889
902
.
27
Trisi
,
P.
,
W.
Rao
, and
A.
Rebaudi
.
A histometric comparison of smooth and rough titanium implants in human low-density jawbone.
Int J Oral Maxillofac Implants
1999
.
14
:
689
698
.
28
Li
,
D-H.
,
B-L.
Liu
,
J-C.
Zou
, and
K-W.
Xu
.
Improvement of osseointegration of titanium dental implants by a modified sandblasting surface treatment: an in vivo interfacial biomechanics study.
Implant Dent
1999
.
8
:
289
294
.
29
Wong
,
M.
,
J.
Eulenberger
,
R.
Schenk
, and
E.
Hunziker
.
Effect of surface topology on the osseointegration of implant materials in trabecular bone.
J Biomed Mater Res
1995
.
29
:
1567
1575
.
30
Buser
,
D.
,
T.
Nydegger
, and
T.
Oxland
.
et al
.
Interface shear strength of titanium implants with a sandblasted and acid-etched surface: a biomechanical study in the maxilla of miniature pigs.
J Biomed Mater Res
1999
.
45
:
75
83
.
31
Piatelli
,
A.
,
L.
Manzon
,
A.
Scarano
,
M.
Paolantonio
, and
M.
Piatelli
.
Histological and histomorphometric analysis of the bone response to machined and sandblasted titanium implants: an experimental study in rabbits.
Int J Oral Maxillofac Implants
1998
.
13
:
805
810
.
32
Orsini
,
G.
,
B.
Assenza
,
A.
Scarano
,
M.
Piattelli
, and
A.
Piattelli
.
Surface analysis of machined versus sandblasted and acid-etched titanium implants.
Int J Oral Maxillofac Implants
2000
.
15
:
779
784
.
33
Baker
,
D.
,
R. M.
London
, and
R.
O'Neal
.
Rate of pull-out strength of dual-etched titanium implants: a comparative study in rabbits.
Int J Oral Maxillofac Implants
1999
.
14
:
722
728
.
34
Pebé
,
P.
,
R.
Barbot
, and
J.
Trinidad
.
et al
.
Countertorque testing and histomorphometric analysis of various implant surfaces in canines: a pilot study.
Implant Dent
1997
.
6
:
259
265
.
35
Klokkevold
,
P. R.
,
R. D.
Nishimura
,
M.
Adachi
, and
A.
Caputo
.
Osseointegration enhanced by chemical etching of the titanium surface: a torque removal study in the rabbit.
Clin Oral Implant Res
1997
.
8
:
442
447
.
36
Wennerberg
,
A.
,
T.
Albrektsson
, and
J.
Lausmaa
.
Torque and histomorphometric evaluation of c.p. titanium screws blasted with 25- and 75-μm-sized particles of Al2O3.
J Biomed Mater Res
1996
.
30
:
251
260
.
37
Dario
,
L. J.
The Spline™ implant interface: analysis and initial clinical experiences.
Compendium Continuing Educ Dent
1998
.
19
:
896
912
.
38
Binon
,
P.
,
F.
Sutter
,
K.
Beaty
,
J.
Brunski
,
H.
Gulbransen
, and
R.
Weiner
.
The role of screws in implant systems.
Int J Oral Maxillofac Implants
1994
.
9
suppl
:
48
63
.
39
Leary
,
J. C.
and
S.
Daher
.
Improving dental care through mechanical engineering.
Dent Surg Prod
1997
.
11
:
30
32
.
40
Ford
,
T. G.
and
N.
MacLarty
.
The Accuracy Verification Stent (AVS) technique.
Implant Soc
1991
.
2
:
4
5, 16
.

Author notes

Stephen T. Swallow, DDS, is with the Center for Restorative Dentistry, 12 Newmarch Street, Kittery, ME 03094. Correspondence should be addressed to Dr Swallow, c/o Mike Warner, 1900 Aston Avenue, Carlsbad, CA 92008 ([email protected]).