Human biopsy of immediately loaded implants is the most important way to determine the occurrence of osseointegration. Implants inserted in sites with poor bone quality have been associated with lower success rates. The aim of this study is to document the early healing processes in a man around an immediately loaded implant retrieved after a 2-month loading period. An implant was inserted in the mandible of a 32-year-old patient and was loaded into a nonfunctional loading mode with a fixed provisional prosthesis the same day of the implant surgery. After 2 months, because the patient had difficulty accepting the implant, the implant was retrieved with a 5-mm trephine drill. Before retrieval, the implant appeared to be clinically osseointegrated, and no mobility was present. The pre-existing bone quality was type D4. The implant was surrounded by newly formed bone lamellae with a width of 200 to 400 μm. In many areas it was possible to observe osteoblasts producing osteoid matrix directly on the implant surface. Bone-to-implant contact percentage was 71% ± 3.2%. Even in a poor bone site and after a healing period of only 2 months, we observed a high bone-to-implant contact percentage. We can confirm that immediately loaded implants placed in soft spongy bone after a 2-month healing period can present mineralized tissue at the interface.

Fibrous tissue has been described at the bone-implant interface in early or immediately loaded implants.1–5 In the past decade, a high clinical and radiographic level of osseointegration has been reported in early and immediately loaded implants. Moreover, high implant survival rates for these implants can be found in the literature.6–71 It has been reported that immediate loading does not lead to disruption of the implant-bone interface.50 The success of functionally stable osteosynthesis systems shows that osteosynthesis screws can be immediately subjected to loading without a loosening of the screw-bone interface.50 

One of the most important changes in implant dentistry has been the increased acceptance of immediate loading as a clinical alternative, in carefully selected cases, with a predictable outcome and with high survival rates.42 However, a cautious approach is needed when transferring to humans the histologic results obtained in animal experimentation.41 Human biopsy of immediately loaded implants is certainly the most important way to determine the occurrence of osseointegration.40 The histologic reports of early or immediately loaded implants in humans reported in the literature are few.16,17,22–25,28,36,44,47,57,72,73 

Primary implant stability and bone quality have been recognized as key features for the success in immediately loaded implants.43 Implants inserted in sites with poor bone quality have been associated with lower success rates.74 This is likely related to the lower bone content and the lower bone-to-implant contact percentages because of the cancellous structure of these sites.74 Also, the implant surface characteristics have been demonstrated to be important for the bone apposition at the interface, with a faster bone formation at rougher surfaces.40 FRIADENT plus surface (DENTSPLY Friadent, Mannheim, Germany) is obtained with a novel grit-blasting and acid-etching technique, and it shows a regular microroughness with pores in the micrometer dimension overlaying a macroroughness structure caused by the grit blasing.75 This results in a porous topography with an hierarchical surface structure.76 The spatial parameters have shown a first macroscopic level of roughness of the dimensions of 100 μm and then a second level of grooves in the dimensions of about 12 to 75 μm, each of which embraces an arrangement of smaller, round groups with diameter of about 1 to 5 μm.76 Recently, we have documented the presence of mineralized tissues at the interface of immediately loaded implants retrieved after a loading period of 6 or 10 months.36,47,72,73 In this study, we attempted to document the healing processes at the interface after a shorter loading period of 2 months.40 

The aim of this study was a histologic and histomorphometric analysis in a man of the bone-titanium interface in an immediately loaded titanium implant with a novel surface that was retrieved after a 2-month loading period.

A 32-year-old male patient presented with a partial edentulism in the right mandible. His medical history was unremarkable and he did not smoke. A 3.8 × 8 XiVE plus implant (DENTSPLY Friadent) was inserted into the posterior mandibular jaw region and was put into a nonfunctional loading mode with a fixed provisional prothesis the same day of the implant surgery.49 The implant stability quotient (ISQ) at implant insertion was 71. The insertion torque was 7.7 N/cm. The last drill was D3.8. (DENTSPLY-Friadent, Mannheim, Germany).

After some weeks, the patient returned to say that he was uncomfortable with the implant and asked that it be removed. He was referred to a psychologist, but after a few consultations he still requested implant removal. It was then decided to follow his wish. Before retrieval, the implant was radiographically and clinically osseointegrated (Figure 1). After 2 months, the implant and surrounding tissues were then retrieved with a 5-mm trephine drill (Straumann, Waldenburg, Sweden) (Figure 2).

Figures 1–2. Figure 1. Periapical radiograph after implant placement before retrieval with a trephine drill. No bone crestal resorption was present. Figure 2. The implant and the surrounding tissues immediately after retrieval

Figures 1–2. Figure 1. Periapical radiograph after implant placement before retrieval with a trephine drill. No bone crestal resorption was present. Figure 2. The implant and the surrounding tissues immediately after retrieval

Close modal

Processing of specimens

The implant and the surrounding tissues were stored immediately in 10% buffered formalin and processed to obtain thin ground sections with the Precise 1 Automated System (Assing, Rome, Italy).77 The specimen was dehydrated in an ascending series of alcohol rinses and embedded in a glycolmethacrylate resin (Technovit 7200 VLC, Kulzer, Wehrheim, Germany). After polymerization, the specimen was sectioned longitudinally along the major axis of the implant with a high-precision diamond disc at about 150 μm and was ground down to about 30 μm. Three slides were obtained, and each was stained with basic fuchsin and toluidine blue. A double staining with von Kossa and acid fuchsin was performed to evaluate the degree of bone mineralization. After polishing, one slide was immersed in silver nitrate for 30 minutes and exposed to sunlight. The slides were then washed under tap water, dried, immersed in basic fuchsin for 5 minutes, and then washed and mounted.

Histomorphometry

Histomorphometry of bone-to-implant contact percentage was carried out with a light microscope (Laborlux S, Leitz, Wetzlar, Germany) connected to a high-resolution video camera (3CCD, JVC KY-F55B; JVC, Yokohama, Japan) and interfaced to a monitor and personal computer (Intel Pentium III 1200 MMX; Intel, Santa Clara, Calif). This optical system was associated with a digitizing pad (Matrix Vision GmbH; Matrix Vision, Oppenweiler, Germany) and a histometry software package with image-capturing capabilities (Image-Pro Plus 4.5, Media Cybernetics Inc, Immagini & Computer Snc, Milano, Italy).

The implant was clinically osseointegrated and stable, and no mobility was present. Radiographically, before the retrieval, a slight vertical crestal bone loss was noted (Figure 1).

The implant was surrounded by newly formed bone (Figure 3). At the coronal level, no infrabony pocket, Howship lacunae, or osteoclasts were present (Figure 4). The first bone-to-implant contact was found at about 1 mm from the shoulder of the implant. The pre-existing bone quality was type D4. No apical epithelial migration was found. No inflammatory infiltrate was present around the implant. No gaps or dense fibrous connective tissue were found at the bone-metal interface (Figure 5).

Figures 3–7. Figure 3. The implant was surrounded by lamellar and woven bone. The bone was in close contact with the implant surface. At the coronal level, no infrabony pocket, Howship lacunae, or osteoclasts were present (acid fuchsin and toluidine blue, original magnification ×12). Figure 4. Higher magnification of the coronal portion of the bone-implant interface. No infrabony pockets or osteoclasts were present (acid fuchsin and toluidine blue, original magnification ×100). Figure 5. Lamellar and woven bone were observed in direct contact with the implant surface; no gaps or connective tissue were present at the bone-implant interface. The first bone-to-implant contact was found at about 1 mm from the shoulder of the implant. The pre-existing bone quality was type D4. No apical epithelial migration was found. No inflammatory infiltrate was present around the implant (acid fuchsin and toluidine blue, original magnification ×100). Figure 6. At the coronal level, osteoblasts were also found in direct contact with the implant surface and producing osteoid matrix directly on the metal surface. Only in a few areas in the coronal portion was it possible to see that this bone was going through an active remodeling process with the presence of some well-structured Haversian canals. Newly formed, strongly stained bone lamellae with a width of 200 to 400 μm were present around the implant (acid fuchsin and toluidine blue, original magnification ×200). Figure 7. In the apical portion of the implant, osteoblasts and newly formed bone were present. No osteoclasts were present. Few marrow spaces were observed directly on the implant surface. The quality of the bone around the apical portion of the implant was poor. Only a few newly formed thin bone trabeculae were present at a distance from the implant surface. No well-structured Haversian canals were present in the bone located at the apical portion of the implant (acid fuchsin and toluidine blue, original magnification ×200)

Figures 3–7. Figure 3. The implant was surrounded by lamellar and woven bone. The bone was in close contact with the implant surface. At the coronal level, no infrabony pocket, Howship lacunae, or osteoclasts were present (acid fuchsin and toluidine blue, original magnification ×12). Figure 4. Higher magnification of the coronal portion of the bone-implant interface. No infrabony pockets or osteoclasts were present (acid fuchsin and toluidine blue, original magnification ×100). Figure 5. Lamellar and woven bone were observed in direct contact with the implant surface; no gaps or connective tissue were present at the bone-implant interface. The first bone-to-implant contact was found at about 1 mm from the shoulder of the implant. The pre-existing bone quality was type D4. No apical epithelial migration was found. No inflammatory infiltrate was present around the implant (acid fuchsin and toluidine blue, original magnification ×100). Figure 6. At the coronal level, osteoblasts were also found in direct contact with the implant surface and producing osteoid matrix directly on the metal surface. Only in a few areas in the coronal portion was it possible to see that this bone was going through an active remodeling process with the presence of some well-structured Haversian canals. Newly formed, strongly stained bone lamellae with a width of 200 to 400 μm were present around the implant (acid fuchsin and toluidine blue, original magnification ×200). Figure 7. In the apical portion of the implant, osteoblasts and newly formed bone were present. No osteoclasts were present. Few marrow spaces were observed directly on the implant surface. The quality of the bone around the apical portion of the implant was poor. Only a few newly formed thin bone trabeculae were present at a distance from the implant surface. No well-structured Haversian canals were present in the bone located at the apical portion of the implant (acid fuchsin and toluidine blue, original magnification ×200)

Close modal

At the coronal level, the newly formed bone was woven and not lamellar bone and completely surrounded the pre-existing cortical bone. A rim of osteoblasts lined the marrow spaces and were producing osteoid matrix. Osteoblasts were also found in direct contact with the implant surface and were producing osteoid matrix directly on the metal surface. Only in a few areas in the coronal portion was it possible to see that this bone was going through an active remodeling process with the presence of some well-structured Haversian canals. The quality of the bone around the apical portion of the implant was poor.

Newly formed, strongly stained bone lamellae with a width of 200 to 400 μm were present around the implant. Far from the implant surface, only a few newly formed thin bone trabeculae were present. No Haversian canals were present in the bone located at the apical portion of the implant. In many fields, it was possible at the interface to observe osteoblasts producing osteoid matrix directly on the implant surface (Figure 6). Few marrow spaces were observed directly on the implant surface. In the apical portion of the implant, osteoblasts and newly formed bone were present, and no osteoclasts were present (Figure 7). Histomorphometric evaluation showed that the bone-to-implant contact percentage was 71% ± 3.2%.

Because the use of abbreviated healing periods is increasing, it is necessary to balance their benefits (eg, shorter time to completion) with the long-term success rates reported with delayed loading protocols41 because no quantitative data exist for the early healing processes in humans.39 In this field, the histologic evidence that it is possible to observe the formation of mineralized tissue at the interface even with shorter healing periods will help support the concept of early loading.41 

Immediate loading can reduce the treatment period because the soft tissues heal simultaneously with the hard tissues according to the contours of the provisional restoration.65 Immediate loading has esthetic, psychological, and functional advantages in eliminating second-stage surgery and in reducing patient discomfort and additional costs of the procedure.39,45,65 Most of the cases of immediately loaded implants reported in the literature were in the mandible.7–9,29,42,52,55,64,69,70 Posterior areas of the jaws have been avoided because of scarce bone quality, higher forces produced during mastication, and presumed higher implant failure rate.45 Most implant failures have been described in sites where the bone density was low at the start of the procedure.45 However, studies need to be conducted in soft-bone areas to evaluate if implant surfaces play an important role in immediate loading success39 and the predictability of immediate loading procedures in this type of anatomic location.39 

It has been documented that the occurrence of mineralized tissue at the interface is mainly related to the biomechanical stability of the implant and to the amount of micromotion.3–5 A threshold of tolerated micromotion has been identified somewhere between 50 and 100 microns.50 Poor implant stability produces a distortional strain with fibrous tissue formation at the interface.3–5 Bone submitted to cyclic micromovements elicits a more physiologic pattern of tissue regeneration than bone that is not stimulated mechanically.50 From a scientific point of view, the tissue integration of dental implants can be considered successful only if the bone-implant interface is maintained in the long term28 and if mineralized tissue is present and remains at the interface with the implants.

There is an absence of information about how much bone is needed at the interface of loaded dental implants,78 even though a recent figure of 50% has been proposed.79 Trisi et al79 found a 47.81% bone-to-implant contact percentage in the maxilla in dual-etched implants retrieved after a 2-month period. Testori et al40 reported a 64.2% bone-to-implant contact percentage in the mandible after a 2-month period. The density of bone at the implant site has been suggested to be important in the amount of bone at the interface79; clinically, host-bone density plays an important role in determining the predictability of immediate loading success.39 In our case, even in a poor bone site, we have observed a high bone-to-implant contact percentage. The type of mineralized tissue at the interface with dental implants in spongious bone is not as satisfying as the extremely dense appearance observed around implants inserted in cortical lamellar bone.80 Our histologic results are similar to those reported by Testori et al,40 who found that in the spongious area the implant surface was covered by an almost continuous thin shell of newly formed bone. This particular arrangement corresponds to the characteristics of contact osteogenesis.40 The clinical efficacy of these thin isolated bone trabeculae to resist loading forces may perhaps be questioned, but the clinical evidence in our case points to a successful osseointegration process because the implant was clinically stable before retrieval. Moreover, Rohrer et al80 have documented that the trabeculae in the cancellous bone area were generally oriented around the implant in a supporting strutlike buttressing pattern.

The good clinical and histologic results of the present study may also relate to the use of an implant with a rough surface.81,82 This surface has been demonstrated to have a hierarchical surface structure because a blasting and etching processes produced a wettable surface.76 This unique wettability characteristic has been hypothesized to lead to an advanced adhesion of noncollagenous proteins such as sialoprotein and osteopontin, which are the preconditions of contact osteogenesis.76 Moreover, higher amounts of fibronectin adsorbed on the FRIADENT plus surface may improve host responses such as osteoblast adhesion.76 The presence of the sharp edges found under scanning electron microscopy on the FRIADENT plus surface could help the adhesion of cells by presenting a differential in the chemistry of the implant surface.83 The proteins adsorbing to the edge could take up a different shape from those adsorbed to a continuously flat surface.83 Furthermore, this surface has been reported to have a higher percentage of tetracycline marked bone.75 

In conclusion, in our study the implant had successfully osseointegrated from a clinical and radiologic point of view and was stable at retrieval time. Mineralized tissue was found covering a large portion of the implant surface with no foreign body or inflammatory reactions visible, remodeling was present in an area around the implant, and we confirm that implants placed in soft spongy bone and immediately loaded after a 2-month healing period can present a high percentage of mineralized tissue at the interface. Primary stability plays an important role in the implant success,39 and it may be the fundamental prerequisite for immediate loading more so than is the anatomic location.39 Micromotion has been reported to positively influence the healing of bone fractures, and optimal healing is not achieved in total absence of micromotion.50 Immediate and early loading of dental implants can then function as a mechanical stimuli for osteoblasts.50 

Immediate loading can therefore be considered an innovative and attractive treatment that can be successfully used today in implantology.43 Despite that retrieved human specimens are only rarely reported in the literature because of ethical reasons,84–90 they play a relevant role in helping understand the biological aspects of the bone response at the interface.

This work was partially supported by the National Research Council (CNR), Rome, Italy; by the Ministry of Education, University, Research (MIUR), Rome, Italy; and by Research Association for Dentistry and Dermatology (AROD), Chieti, Italy.

1
Adell
,
R.
,
U.
Lekholm
, and
Brånemark P. I.
Rockler
.
A 15 year study of osseointegrated implants in the treatment of the edentulous jaw.
Int J Oral Surg
1981
.
10
:
387
416
.
2
Brånemark
,
P. I.
,
B. O.
Hansson
, and
R.
Adell
.
et al
.
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
Scand Reconstr Surg
1977
.
11
suppl 16
:
1
132
.
3
Brunski
,
J. B.
Forces on dental implants and interfacial stress transfer.
In: Laney WR, Tolman DE, eds. Tissue Integration in Oral, Orthopaedic and Maxillofacial Reconstruction. Chicago, Ill: Quintessence; 1992:108–124
.
4
Brunski
,
J. B.
Influence of biomechanical factor at the bone-biomaterial interface.
In: Davies JE, ed. The Bone-Biomaterial Interface. Toronto, Ontario, Canada: Toronto University Press; 1991:391–405
.
5
Carter
,
D. R.
and
N. J.
Giori
.
Effect of mechanical stress on tissue differentiation in the bony implant bed.
In: Davies JE, ed. The Bone-Biomaterial Interface. Toronto, Ontario, Canada: Toronto University Press; 1991:367–379
.
6
Salama
,
H.
,
L. F.
Rose
,
M.
Salama
, and
N. J.
Betts
.
Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics. A technique reexamined: two case reports.
Int J Periodont Restor Dent
1995
.
15
:
345
361
.
7
Chiapasco
,
M.
,
C.
Gatti
,
E.
Rossi
,
W.
Haefliger
, and
T. H.
Markwalder
.
Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases.
Clin Oral Implant Res
1997
.
8
:
48
57
.
8
Tarnow
,
D. P.
,
S.
Emtiaz
, and
A.
Classi
.
Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data.
Int J Oral Maxillofac Implants
1997
.
12
:
319
324
.
9
Schnitman
,
P. A.
,
P. S.
Wöhrle
,
J. E.
Rubenstein
,
J. D.
DaSilva
, and
N. H.
Wang
.
Ten-year results for Branemark implants immediately loaded with fixed prostheses at implant placement.
Int J Oral Maxillofac Implants
1997
.
12
:
495
503
.
10
Randow
,
K.
,
I.
Ericsson
,
K.
Nilner
,
P.
Petersson
, and
P. O.
Glantz
.
Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study after 24 months.
Clin Oral Implant Res
1999
.
10
:
8
15
.
11
Szmukler-Moncler
,
S.
,
H.
Salama
,
Y.
Reingewirtz
, and
J. H.
Dubruille
.
Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature.
J Biomed Mater Res (Appl Biomater)
1998
.
43
:
192
203
.
12
Szmukler-Moncler
,
S.
,
A.
Piattelli
,
G. A.
Favero
, and
J. H.
Dubruille
.
Considerations preliminary to the application of early and immediate loading protocols in dental implantology.
Clin Oral Implant Res
2000
.
11
:
12
25
.
13
Chaushu
,
G.
,
S.
Chaushu
,
A.
Tzohar
, and
D.
Dayan
.
Immediate loading of single-tooth implants: immediate versus non-immediate implantation. A clinical report.
Int J Oral Maxillofac Surg
2001
.
16
:
267
272
.
14
Lazzara
,
R. J.
,
S. S.
Porter
,
T.
Testori
,
J.
Galante
, and
L.
Zetterquist
.
A prostective multicenter study evaluating loading of Osseotite implants two months after placement: one-year results.
J Esthet Dent
1998
.
6
:
280
289
.
15
Misch
,
C. E.
Non-functional immediate teeth in partially edentulous patients: a pilot study of 10 consecutive cases using the Maestro dental implant system. Compendium.
1998; 19:25–36
.
16
Linkow
,
L. I.
,
K.
Donath
, and
J. E.
Lemons
.
Retrieval analyses of a blade implant after 231 months of clinical function.
Implant Dent
1992
.
1
:
37
43
.
17
Trisi
,
P.
,
M.
Emanuelli
,
M.
Quaranta
, and
A.
Piattelli
.
A light microscopy, scanning electron microscopy and laser scanning microscopy analysis of retrieved blade implants after 7 to 20 years of clinical function.
J Periodontol
1993
.
64
:
374
378
.
18
Sagara
,
M.
,
Y.
Akagawa
,
H.
Nikai
, and
H.
Tsuru
.
The effects of early occlusal loading on one-stage titanium alloy implants in beagle dogs: a pilot study.
J Prosthet Dent
1993
.
69
:
281
288
.
19
Piattelli
,
A.
,
A.
Ruggeri
,
P.
Trisi
,
N.
Romasco
, and
M.
Franchi
.
A histologic and histomorphometric study of the bone reactions to non submerged unloaded and loaded single implants in monkeys.
J Oral Implantol
1993
.
19
:
314
320
.
20
Piattelli
,
A.
,
M.
Corigliano
,
A.
Scarano
, and
M.
Quaranta
.
Bone reactions to early occlusal loading of two-stage titanium plasma-sprayed implants: a pilot study in monkeys.
Int J Periodont Restor Dent
1997
.
17
:
163
169
.
21
Piattelli
,
A.
,
M.
Corigliano
,
A.
Scarano
,
G.
Costigliola
, and
M.
Paolantonio
.
Immediate loading of titanium plasma-sprayed implants: a pilot study in monkeys.
J Periodontol
1998
.
69
:
321
327
.
22
Piattelli
,
A.
,
P.
Trisi
,
N.
Romasco
, and
M.
Emanuelli
.
Histological analysis of a screw implant retrieved from man: influence of early loading and primary stability.
J Oral Implantol
1993
.
19
:
303
306
.
23
Piattelli
,
A.
,
M.
Corigliano
, and
A.
Scarano
.
Microscopical observations of the osseous responses in early loaded human titanium implants: a report of two cases.
Biomaterials
1996
.
17
:
1333
1337
.
24
Piattelli
,
A.
,
M.
Paolantonio
,
M.
Corigliano
, and
A.
Scarano
.
Immediate loading of titanium plasma-sprayed screw-shaped implants in man: a clinical and histological report of two cases.
J Periodontol
1997
.
68
:
591
597
.
25
Piattelli
,
A.
,
A.
Scarano
, and
M.
Paolantonio
.
Immediately loaded screw implant removed for fracture after a 15-year loading period: histological and histochemical analysis.
J Oral Implantol
1997
.
23
:
75
79
.
26
Roynesdal
,
A. K.
,
B.
Amunrud
, and
H. R.
Hannaes
.
A comparative clinical investigation of 2 early loaded ITI dental implants supporting an overdenture in the mandible.
Int J Oral Maxillofac Implants
2001
.
16
:
246
251
.
27
Branemark
,
P. I.
,
P.
Engstrand
, and
L. O.
Ohrnell
.
et al
.
Branemark Novum: a new treatment concept for rehabilitation of the edentulous treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study.
Clin Implant Dent Relat Res
1999
.
1
:
2
16
.
28
Ledermann
,
P. D.
,
R. K.
Schenk
, and
D.
Buser
.
Long-lasting osseointegration of immediately loaded bar-connected TPS screws after 12 years of function: a histologic case report of a 95-year-old patient.
Int J Periodont Restor Dent
1998
.
18
:
558
563
.
29
Gatti
,
C.
,
W.
Haefliger
, and
M.
Chiapasco
.
Implant-retained mandibular overdentures with immediate loading: a prospective study of ITI implants.
Int J Oral Maxillofac Implants
2000
.
15
:
383
388
.
30
Horiuchi
,
K.
,
H.
Uchida
,
K.
Yamamoto
, and
M.
Sugimura
.
Immediate loading of Branemark system implants following placement in edentulous patients: a clinical report.
Int J Oral Maxillofac Implants
2000
.
15
:
824
830
.
31
Malò
,
P.
,
B.
Rangert
, and
L.
Dvarsater
.
Immediate function of Branemark implants in the esthetic zone: a retrospective study with 6 months to 4 years of follow-up.
Clin Implant Dent Relat Res
2000
.
2
:
137
145
.
32
Lazzara
,
R. J.
,
S. S.
Porter
,
T.
Testori
,
J.
Galante
, and
L.
Zetterquist
.
A prospective multicenter study evaluating loading of Osseotite implants two months after placement: one-year results.
J Esthet Dent
1998
.
10
:
280
289
.
33
Corso
,
M.
,
C.
Sirota
,
J.
Fiorellini
,
F.
Rasool
,
S.
Szmukler-Moncler
, and
H. P.
Weber
.
Clinical and radiographic evaluation of early loaded free-standing dental implants with various coatings in beagle dogs.
J Prosthet Dent
1999
.
82
:
428
435
.
34
Jo
,
H. Y.
,
P. K.
Hobo
, and
S.
Hobo
.
Freestanding and multiunit immediate loading of the expandable implant: an up-to-40 month prospective survival study.
J Prosthet Dent
2001
.
85
:
148
155
.
35
Ericsson
,
I.
,
H.
Nilson
,
T.
Lindh
,
K.
Nilner
, and
K.
Randow
.
Immediate functional loading of Branemark single tooth implants. An 18 months' clinical pilot follow-up study.
Clin Oral Implant Res
2000
.
11
:
26
33
.
36
Degidi
,
M.
,
G.
Petrone
,
G.
Iezzi
, and
A.
Piattelli
.
Histologic evaluation of 2 human immediately loaded and 1 submerged titanium implants inserted in the posterior mandible and retrieved after 6 months.
J Oral Implantol
2003
.
29
:
223
229
.
37
Jaffin
,
R. A.
,
A.
Kumar
, and
C. L.
Berman
.
Immediate loading of implants in partially and fully edentulous jaws: a series of 27 case reports.
J Periodontol
2000
.
71
:
833
838
.
38
Ganeles
,
S. J.
,
M. M.
Rosenberg
,
R. L.
Holt
, and
L. H.
Reichman
.
Immediate loading of implants with fixed restorations in the completely edentulous mandible: report of 27 patients from a private practice.
Int J Oral Maxillfac Implants
2001
.
16
:
418
426
.
39
Gapski
,
R.
,
H. L.
Wang
,
P.
Mascarenhas
, and
N. P.
Lang
.
Critical review of immediate implant loading.
Clin Oral Implant Res
2003
.
14
:
515
527
.
40
Testori
,
T.
,
S.
Szmukler-Moncler
,
L.
Francetti
,
M.
Del Fabbro
,
P.
Trisi
, and
R. L.
Weinstein
.
Healing of Osseotite implants under submerged and immediate loading conditions in a single patient: a case report and interface analysis after 2 months.
Int J Periodont Restor Dent
2002
.
22
:
345
353
.
41
Vernino
,
A. R.
,
S. S.
Kohles
,
R. A.
Holt
,
H. M.
Lee
,
R. F.
Caudill
, and
J. N.
Kenealy
.
Dual-etched implants loaded after 1- and 2-month healing periods: a histologic comparison in baboons.
Int J Periodont Restor Dent
2002
.
22
:
399
407
.
42
Testori
,
T.
,
A.
Meltzer
, and
M.
Sel Fabbro
.
et al
.
Immediate occlusal loading of Osseotite implants in the lower edentulous jaw. A multicenter prospective study.
Clin Oral Implant Res
2004
.
15
:
278
284
.
43
Romanos
,
G. E.
Present status of immediate loading of oral implants.
J Oral Implantol
2004
.
30
:
189
197
.
44
Proussaefs
,
P.
and
J.
Lozada
.
Immediate loading of hydroxyapatite-coated implants in the maxillary premolar area: three-year results of a pilot study.
J Prosthet Dent
2004
.
91
:
228
233
.
45
Lekholm
,
U.
Immediate/early loading of oral implants in compromised patients.
Periodontology 2000
2003
.
33
:
194
203
.
46
Glauser
,
R.
,
L.
Sennerby
, and
N.
Meredith
.
et al
.
Resonance frequency analysis of implants subjected to immediate or early occlusal loading. Successful vs failing implants.
Clin Oral Implant Res
2004
.
15
:
428
434
.
47
Degidi
,
M.
,
G.
Petrone
,
G.
Iezzi
, and
A.
Piattelli
.
Histologic evaluation of a human immediately loaded titanium implant with a porous anodized surface.
Clin Implant Dent Relat Res
2002
.
4
:
110
114
.
48
Testori
,
T.
,
S.
Szmukler-Moncler
, and
L.
Francetti
.
et al
.
Immediate loading of Osseotite implants. A case report and histologic analysis after 4 months of occlusal loading.
Int J Periodont Restor Dent
2001
.
21
:
451
459
.
49
Degidi
,
M.
and
A.
Piattelli
.
Immediate functional and non functional loading of dental implants: a 2 to 60 months follow-up study of 646 titanium implants.
J Periodontol
2003
.
74
:
225
241
.
50
Meyer
,
V.
,
H. P.
Wiesmann
,
T.
Fillies
, and
U.
Joos
.
Early tissue reaction at the interface of immediately loaded dental implants.
Int J Oral Maxillofac Implants
2003
.
18
:
489
499
.
51
Cannizzaro
,
G.
and
M.
Leone
.
Restoration of partially edentulous patients using dental implants with a microtextured surface: a prospective comparison of delayed and immediate fully occlusal loading.
Int J Oral Maxillofac Implants
2003
.
18
:
512
522
.
52
Chiapasco
,
M.
and
C.
Gatti
.
Implant-retained mandibular overdentures with immediate loading: a 3- to 8-year prospective study on 328 implants.
Clin Implant Dent Relat Res
2003
.
5
:
29
38
.
53
Misch
,
C. E.
and
M.
Degidi
.
Five-year prospective study of immediate/early loading of fixed prostheses in completely edentulous jaws with a bone quality based implant system.
Clin Implant Dent Relat Res
2003
.
5
:
17
28
.
54
Balshi
,
T. J.
and
G. J.
Wolfinger
.
Teeth in a Day® for the maxilla and the mandible: case report.
Clin Implant Dent Relat Res
2003
.
5
:
11
16
.
55
Rocci
,
A.
,
M.
Martignoni
, and
J.
Gottlow
.
Immediate loading of Branemark system® TiUnite™ and machined-surface implants in the posterior mandible: a randomized open-ended clinical trial.
Clin Implant Dent Relat Res
2003
.
5
suppl1
:
57
63
.
56
Olsson
,
M.
,
G.
Urde
,
J. B.
Andersen
, and
L.
Sennerby
.
Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: results after 1 year of loading, case series.
Clin Implant Dent Relat Res
2003
.
5
suppl1
:
81
87
.
57
Rocci
,
A.
,
M.
Martignoni
,
P.
Miranda Burgos
,
J.
Gottlow
, and
L.
Sennerby
.
Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible.
Clin Implant Dent Relat Res
2003
.
5
suppl1
:
88
98
.
58
Malò
,
P.
,
B.
Rangert
, and
M.
Nobre
.
“All-on-four” immediate function concept with Branemark System® implants for completely edentulous mandibles: a retrospective clinical study.
Clin Implant Dent Relat Res
2003
.
5
suppl1
:
2
9
.
59
Calandriello
,
R.
,
M.
Tomatis
, and
B.
Rangert
.
Immediate loading of Branemark System® implants with enhanced initial stability: a prospective 1- to 2-year clinical and radiographic study.
Clin Implant Dent Relat Res
2003
.
5
suppl1
:
10
20
.
60
Vanden Bogaerde
,
L.
,
G.
Pedretti
,
P.
Dellacasa
,
M.
Mozzati
, and
B.
Rangert
.
Early function of splinted implants in maxillas and posterior mandibles using Branemark System® machined-surface implants: an 18-month prospective clinical multicenter study.
Clin Implant Dent Relat Res
2003
.
5
suppl1
:
21
28
.
61
Rocci
,
A.
,
M.
Martignoni
, and
J.
Gottlow
.
Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: a retrospective 3-year clinical study.
Clin Implant Dent Relat Res
2003
.
5
suppl1
:
29
36
.
62
Malò
,
P.
,
B.
Friberg
,
G.
Polizzi
,
F.
Gualini
,
T.
Vighagen
, and
B.
Rangert
.
Immediate and early function of Branemark System® implants placed in the esthetic zone: a 1-year prospective clinical multicenter study.
Clin Implant Dent Relat Res
2003
.
5
suppl1
:
37
46
.
63
Glauser
,
R.
,
A. K.
Lundgren
, and
J.
Gottlow
.
et al
.
Immediate occlusal loading of Branemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study.
Clin Implant Dent Relat Res
2003
.
5
suppl1
:
47
56
.
64
Cooper
,
L. F.
,
A.
Rahman
,
J.
Moriarty
,
N.
Chaffee
, and
D.
Sacco
.
Immediate mandibular rehabilitation with endosseous implants: simultaneous extraction, implant placement and loading.
Int J Oral Maxillofac Implants
2002
.
17
:
517
525
.
65
Proussaefs
,
P.
,
J.
Kan
,
J.
Lozada
,
A.
Kleinman
, and
A.
Farnos
.
Effect of immediate loading with threaded hydroxyapatite-coated root-form implants on single premolar replacements: a preliminary report.
Int J Oral Maxillofac Implants
2002
.
17
:
567
572
.
66
Raghoebar
,
G. M.
,
P.
Schoen
,
H. J. A.
Meijer
,
K.
Stellingsma
, and
A.
Vissink
.
Early loading of endosseous implants in the augmented maxilla: a 1-year prospective study.
Clin Oral Implant Res
2003
.
14
:
697
702
.
67
Vergara
,
J. A.
and
R. G.
Caffesse
.
Immediate replacement of single upper posterior teeth: a report of cases.
Clin Implant Dent Relat Res
2003
.
5
:
130
136
.
68
Aparicio
,
C.
,
B.
Rangert
, and
L.
Sennerby
.
Immediate/early loading of dental implants: a report from the Sociedad Espanola de Implantes. World Congress Consensus Meeting in Barcelona, Spain.
Clin Implant Dent Relat Res
2003
.
5
:
57
60
.
69
Chee
,
W.
and
S.
Jivraj
.
Efficiency of immediately loaded mandibular full-arch implant restorations.
Clin Implant Dent Relat Res
2003
.
5
:
52
56
.
70
Raghoebar
,
G. M.
,
B.
Friberg
,
I.
Grunert
,
J. A.
Hobkirk
,
G.
Tepper
, and
I.
Wendelhag
.
3-year prospective multicenter study on one-stage implant surgery and early loading in the edentulous mandible.
Clin Implant Dent Relat Res
2003
.
5
:
39
46
.
71
Fischer
,
K.
and
T.
Stenberg
.
Early loading of ITI implants supporting a maxillary full-arch prosthesis: 1-year data of a prospective, randomized study.
Int J Oral Maxillofac Implants
2004
.
19
:
374
381
.
72
Degidi
,
M.
,
A.
Scarano
,
G.
Petrone
, and
A.
Piattelli
.
Histological analysis of clinically retrieved immediately loaded implants: a report of 11 cases.
Clin Implant Dent Relat Res
2003
.
5
:
89
94
.
73
Degidi
,
M.
,
A.
Scarano
,
G.
Iezzi
, and
A.
Piattelli
.
Peri-implant bone in immediately loaded titanium implants: an histologic and histomorphometric evaluation in man. A report of 2 cases.
Clin Implant Dent Relat Res
2003
.
5
:
170
175
.
74
Weng
,
D.
,
M.
Hoffmeyer
,
M. B.
Hurzeler
, and
E. J.
Richter
.
Osseotite® vs machined surface in poor bone quality. A study in dogs.
Clin Oral Implant Res
2003
.
14
:
703
708
.
75
Papalexiou
,
V.
,
A. B.
Novaes
,
M. F. M.
Grisi
,
S. S. L. S.
Souza
,
M.
Taba
, and
J. K.
Kajiwara
.
Influence of implant microstructure on the dynamics of bone healing around immediate implants placed into periodontally infected sites. A confocal laser scanning microscopic study.
Clin Oral Implant Res
2004
.
15
:
44
53
.
76
Rupp
,
F.
,
L.
Scheideler
,
D.
Rehbein
,
D.
Axmann
, and
J.
Geis-Gerstorfer
.
Roughness induced dynamic changes of wettability of acid etched titanium implant modifications.
Biomaterials
2004
.
25
:
1429
1438
.
77
Piattelli
,
A.
,
A.
Scarano
, and
M.
Quaranta
.
High-precision, cost-effective system for producing thin sections of oral tissues containing dental implants.
Biomaterials
1997
.
18
:
577
579
.
78
Uehara
,
T.
,
K.
Takaoka
, and
K.
Ito
.
Histological evidence of osseointegration in human retrieved fractured hydroxyapatite-coated screw-type implants: a case report.
Clin Oral Implant Res. 2004;15:540–545
.
79
Trisi
,
P.
,
R.
Lazzara
,
A.
Rebaudi
,
W.
Rao
,
T.
Testori
, and
S. S.
Porter
.
Bone-implant contact on machined and dual acid-etched surfaces after 2 months of healing in the human maxilla.
J Periodontol
2003
.
74
:
945
956
.
80
Rohrer
,
M. D.
,
R. R.
Sobczack
,
H. S.
Prasad
, and
H. F.
Morris
.
Postmortem histologic evaluation of mandibular titanium and maxillary hydroxyapatite-coated implants from 1 patient.
Int J Oral Maxillofac Implants
1999
.
14
:
579
586
.
81
Lazzara
,
R. J.
,
T.
Testori
,
P.
Trisi
,
S. S.
Porter
, and
R. L.
Weinstein
.
A human histologic analysis of osseotite and machined surfaces using implants with 2 opposing surfaces.
Int J Periodont Restor Dent
1999
.
19
:
117
129
.
82
Degidi
,
M.
,
G.
Petrone
,
G.
Iezzi
, and
A.
Piattelli
.
Bone contact around acid-etched implants: a histological and histomorphometrical evaluation of two human-retrieved implants.
J Oral Implantol
2003
.
29
:
13
18
.
83
Riehle
,
M. O.
,
M. J.
Dalby
,
H.
Johnstone
,
A.
Macintosh
, and
S.
Affrossman
.
Cell behaviour of rat calvaria bone cells on surfaces with random nanometric features.
Mater Sci Eng C
2003
.
23
:
337
340
.
84
Becker
,
W.
,
L.
Sennerby
,
B. E.
Becker
, and
P.
Henry
.
Clinical and histologic findings for microimplants placed in one stage and loaded for three months: a case report.
Clin Implant Dent Relat Res
2002
.
4
:
47
52
.
85
Rohrer
,
M. D.
,
R. A.
Bulard
, and
M. K.
Patterson
.
Maxillary and mandibular titanium implants 1 year after surgery: histologic examination in a cadaver.
Int J Oral Maxillofac Implants
1995
.
10
:
466
473
.
86
Gores
,
R. J.
,
C. K.
Hayes
, and
K. K.
Unni
.
Post mortem examination of six maxillary Core-Vent implants: report of a case.
J Oral Maxillofac Surg
1989
.
47
:
302
306
.
87
Cappuccilli
,
M.
,
M.
Conte
, and
S. T.
Praiss
.
Placement and postmortem retrieval of a 28-year-old implant: a clinical and histologic report.
J Am Dent Assoc
2004
.
135
:
324
329
.
88
Takeshita
,
F.
,
Y.
Ayukawa
, and
T.
Suetsugu
.
et al
.
Histologic investigation of hollow implants retrieved for psychological reasons.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
1996
.
82
:
379
385
.
89
Proussaefs
,
P.
,
J.
Lozada
, and
M.
Ojano
.
Histologic evaluation of threaded HA-coated root-form implants after 3.5 to 11 years of function: a report of three cases.
Int J Periodont Restor Dent
2001
.
21
:
21
29
.
90
Proussaefs
,
P. T.
,
D. N.
Tatakis
,
J.
Lozada
,
N.
Caplanis
, and
M. D.
Rohrer
.
Histologic evaluation of hydroxyapatite-coated root-form implants retrieved after 7 years in function: a case report.
Int J Oral Maxillofac Implants
2000
.
15
:
438
443
.

Author notes

Marco Degidi, MD, DDS, is a professor, Antonio Scarano, MD, DDS, is a researcher, Giovanna Iezzi, DDS, is a research fellow, and Adriano Piattelli, MD, DDS, is a professor of Oral Medicine and Pathology in the Dental School, University of Chieti-Pescara, Chieti, Italy. Address correspondence to Dr Piattelli at Via F. Sciucchi 63, 66100 Chieti, Italy ([email protected])