As computerized tomography (CT) becomes more widespread in implant treatment planning, dentists are bound to encounter more uncharacteristic anatomical conditions in the jaws. This retrospective study examined the prevalence of one such anatomic variance on 78 CT scans of human mandibles. Irregular heterogeneous circular radiopacities with internal radiolucencies were present in a majority (97.4%) of the CT scans examined; however, the phenomenon only appeared pronounced in 28.9% of this group. Bone radiodensity was higher in the regions with the phenomenon as compared with adjacent bone without the phenomenon, which suggested no adverse indications for implant placement.

In recent literature reviews on dental implants in the new millennium,1,6 it has become clear that one of the fastest growing segments and most important developments in modern dentistry has been permanent tooth replacement with dental implants. In the industrial world, over 240 million people lack at least one tooth. It is estimated that 40% of the Western population is missing one or more teeth. In the United States alone, about 10% of the population is edentulous, and every year approximately two million Americans lose teeth due to sporting accidents. Furthermore, edentulism is a public health concern that affects millions of people. According to Douglass et al,7 the 10% decline in edentulism experienced in recent decades will be offset by an increase in the elderly population, and dentists will find that a considerable number of the patients will continue to need complete denture services.

As imaging technologies for dental implant treatment become increasingly sophisticated, clinicians are likely to encounter a greater diversity of anatomical conditions that fall outside the norm. In many instances, the presurgical analysis of implant sites is enhanced by the use of new imaging technologies, such as cone beam computerized tomography (CT) and surgical/prosthetic guidance technologies. Cone beam CT produces image data that is manipulated by software for analysis in sagital, axial, and coronal planes. Associated software is also utilized to produce 3-dimensional reformatted views that have never before been available outside of medical CT imaging. Images produced by cone beam CT reveal anatomic conditions that are often undetectable on conventional dental radiographs and that may require interpretation.

For years, edentulism has been treated with implant-supported overdentures,8 although recently there has been considerable interest in full-arch screw-retained prostheses with distal extensions (hybrid prostheses).9,10 These screw-retained prostheses represent a viable treatment option for mandibular and/or maxillary edentulism. The hybrid prostheses consist of a screw-retained metal framework supporting the denture teeth and base. In the case of lower hybrid prosthesis, the implants are predominantly placed between the mental foramen, including the midline region of the mandible (Figures 1 and 2).

Figure 1.

A mandibular full-arch screw-retained prosthesis with distal extensions (hybrid prosthesis seen from an occlusal view (A) and facial view (B). The hybrid prosthesis is supported by 5 implants (arrows).

Figure 1.

A mandibular full-arch screw-retained prosthesis with distal extensions (hybrid prosthesis seen from an occlusal view (A) and facial view (B). The hybrid prosthesis is supported by 5 implants (arrows).

Close modal
Figure 2.

The screw-retained prosthesis consists of a metal framework supporting the denture teeth and base. In the case of lower screw-retained prosthesis, the implants are predominantly placed between the mental foramen, including the mandibular symphysis region under review.

Figure 2.

The screw-retained prosthesis consists of a metal framework supporting the denture teeth and base. In the case of lower screw-retained prosthesis, the implants are predominantly placed between the mental foramen, including the mandibular symphysis region under review.

Close modal

Historically, the overall success rate of dental implants has been relatively high.11,16 While some clinicians limit their presurgical dental implant treatment planning to the evaluation of study casts, probing the depth of the mucosa over the bone, and the use of panoramic and/or other plain radiographs, the number of implant surgeons using cone beam CT imaging for presurgical implant site assessment is on the rise. According to numerous studies,17,23 the primary reason for this trend is that cone beam CT provides 3-dimensional visual capabilities with precise anatomic measurements and low dose radiation. While the clinical significance of CT-based imaging and surgical/prosthetic guidance software programs is currently being investigated, several publications suggested that optimal, and at times critical, implant size selection, orientation and placement is significantly aided by these 3-dimensional radiographic and guidance software programs.24,27 

Prior to commencing this study, the authors have incidentally observed that presurgical CT diagnostic imaging performed in preparation for implant placement in the anterior region of the mandible often revealed an anatomic variance in the midline of the mandibular symphysis region. It has the appearance of irregular heterogeneous circular radiopacities with radiolucencies within them. At times, it is also associated with lingual exostoses in the symphysis region. This anatomic variance has been observed in both edentulous and dentate cases (Figures 3 and 4).

Figure 3.

Cone beam CT study performed while the patient was wearing an imaging guide with radiopaque restorative markers seen in the panoramic view (A) and cross sections (B). Each cross-section's number (80, 81, and 83) corresponds with the same number on the panoramic ruler. The markers seen on the panoramic and cross-sectional images represent optimal prosthetically driven trajectories for implants in the anterior region of the mandible, between the right and left mental foramina. Arrows show the anatomic variance.

Figure 3.

Cone beam CT study performed while the patient was wearing an imaging guide with radiopaque restorative markers seen in the panoramic view (A) and cross sections (B). Each cross-section's number (80, 81, and 83) corresponds with the same number on the panoramic ruler. The markers seen on the panoramic and cross-sectional images represent optimal prosthetically driven trajectories for implants in the anterior region of the mandible, between the right and left mental foramina. Arrows show the anatomic variance.

Close modal
Figure 4.

Incidental anatomic condition of fibrocartilaginous joint seen in the midline of a dentate mandibular symphysis region (arrows). Each number on the cross sections (60, 61, 63, and 64) corresponds with the same number on the panoramic ruler.

Figure 4.

Incidental anatomic condition of fibrocartilaginous joint seen in the midline of a dentate mandibular symphysis region (arrows). Each number on the cross sections (60, 61, 63, and 64) corresponds with the same number on the panoramic ruler.

Close modal

The objective of this retrospective study was to determine the prevalence and bone density in Hounsfield units (HU)28,29 of this anatomic variance, with the goal of better understanding its clinical significance relative to implant fixation.

Between April 2005 and October 2006, 390 CT scans of the mandible were performed on patients referred to the Craniofacial Digital Imaging Center in Rochester, New York, for various diagnostic and treatment planning purposes. While some CT scans were ordered for orthodontic and complex exodontia purposes, the majority of the referrals were for diagnostic scans in preparation for dental implant treatment. CT scans were performed using the cone beam CT imaging technology (i-CAT, Imaging Sciences International, Hatfield, PA). To avoid any potential for bias, a random sample of 78 scans representing every fifth case was selected for this review from the total 390 cone beam CT scans of the mandible.

Before commencing the study, examiner 1 (SL) and examiner 2 (DMA) underwent inter-examiner calibration by reviewing several scans together and concurring on the appearance of such irregular heterogeneous circular radiopacities with radiolucencies within them observed in the mandibular symphysis region. Both the cone beam CT panoramic and relevant cross-section views in the mandibular symphysis region were reviewed for the presence of such anatomic variances.

Bone density in HU, a quantitative measure of the bone radiodensity, was gauged in the regions of interest, both within the anatomic variances and in otherwise normal sites distal to those locations. Mean bone density values were calculated by using the cone beam CT imaging technology software (i-CAT).

Of the 78 CT scans selected for this investigation, 27 were in male patients (34.6%) and 51 were in female patients (65.4%). Mean age was 57 (range = 14 to 87) years. Irregular heterogeneous circular radiopacities with radiolucencies within them were found in the mandibular symphysis region in 76 of the 78 CT scans selected for review (97.4%). Within this group exhibiting the phenomenon, 22 (28.9%) showed a large anatomic variance with pronounced lingual exostoses in the symphysis region and 54 (71.1%) appeared mild. Two scans displayed no such anatomic variance.

The mean bone density in Hounsfield units within the anatomic variance was 821.6 HU, ranging in density from 22.7 HU to 1544 HU. The mean bone density observed within trabecular sites distal to the anatomic variance was 319.74 HU, ranging in density from −282.4 HU to 1056.4 HU.

All medical histories of these patients, which were recorded at their initial visit, were reviewed again. It was determined that there were no common denominators among the medical histories of those subjects who exhibited the anatomic variance in the anterior region of the mandibular symphysis.

As the use of implants continues to revolutionize the dental profession, cone beam CT has emerged in recent years as a useful diagnostic procedure for preoperative assessment and planning of dental implant placement. Cone beam CT provides 3-dimensional cross-sectional views of the jaws at an average distortion rate of 0.2mm.17 This feature alone would allow for more accurate and predictable treatment planning at it pertains to locating the mandibular nerve and other critical anatomical landmarks, in comparison to conventional radiography.

The present study reviewed cone beam CT images of the mandibular symphysis region to determine the prevalence of heterogeneous circular radiopacities with radiolucencies within them and gauge the associated bone radiodensity in a random population of patients, many of whom were scheduled to undergo implant surgery in the anterior region of the mandible.

While no biopsies were performed to obtain histological data on these anatomic variances, it is assumed that they are most likely developmental rarefactions (regions of decreased particle density) and radiopacities (regions of increased particle density). The mere fact that the associated mean bone radiodensity within the anatomic variance measured above the mean bone radiodensity observed in adjacent sites suggests that there are no limitations from a bone quality and implant fixation perspective in these regions.

While irregular heterogeneous circular radiopacities with internal radiolucencies appeared pronounced in approximately 28% of all CT scans reviewed, bone radiodensity was also higher in these regions compared to adjacent bone without the phenomenon, which suggested no adverse indications for implant placement.

1
Dental endosseous implants: an update.
ADA Council on Scientific Affairs
J Am Dent Assoc.
2004
.
135
1
:
92
97
.
2
Kohavi
,
D.
,
G.
Azran
,
L.
Shapira
, and
N.
Casap
.
Retrospective clinical review of dental implants placed in a university training program.
J Oral Implantol.
2004
.
30
1
:
23
29
.
3
Sullivan
,
D. Y.
Anterior single-tooth dental implant restorations: now is the perfect time to recall significant contributions.
J Esthet Restor Dent.
2003
.
15
5
:
305
312
.
4
Taylor
,
T. D.
and
J. R.
Agar
.
Twenty years of progress in implant prosthodontics.
J Prosthet Dent.
2002
.
88
1
:
89
95
.
5
Griggs
,
J. A.
,
V. A.
Marker
,
B. H.
Miller
,
Z.
Cai
,
J.
Santa Cruz
, and
T.
Okabe
.
Dental materials in the new millennium: research at Baylor College of Dentistry and a look at new trends.
Tex Dent J.
2000
.
117
2
:
26
36
.
6
Binon
,
P. P.
Implants and components: entering the new millennium.
Int J Oral Maxillofac Implants.
2000
.
15
1
:
76
94
.
7
Douglass
,
C. W.
,
A.
Shih
, and
L.
Ostry
.
Will there be a need for complete dentures in the United States in 2020?
J Prosthet Dent.
2002
.
87
1
:
5
8
.
8
Schwartz-Arad
,
D.
,
N.
Kidron
, and
E.
Dolev
.
A long-term study of implants supporting overdentures as a model for implant success.
J Periodontol.
2005
.
76
9
:
1431
1435
.
9
Testori
,
T.
,
A.
Meltzer
, and
M.
Del Fabbro
.
et al
.
Immediate occlusal loading of osseotite implants in the lower edentulous jaw. A multicenter prospective study.
Clin Oral Implants Res.
2004
.
15
3
:
278
284
.
10
Aalam
,
A. A.
,
H.
Nowzari
, and
A.
Krivitsky
.
Functional restoration of implants on the day of surgical placement in the fully edentulous mandible: a case series.
Clin Implant Dent Relat Res.
2005
.
7
1
:
10
16
.
11
Adell
,
R.
,
U.
Lekholm
,
B.
Rockier
, and
P. I.
Branemark
.
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw.
Int J Oral Surg.
1981
.
10
:
387
416
.
12
James
,
R. A.
,
J. L.
Lozada
,
P. H.
Truitt
,
B. E.
Foust
, and
S. A.
Jovanovic
.
Subperiosteal implants.
CDAJ.
1988
.
16
:
10
14
.
13
PA. Schnitman, LB. Shulman eds.
Dental implants: benefit and risk. HHS Summaries.
NIH-Harvard Consensus Development Conference. DHHS (NIH) 81–1531,
.
1980
.
14
Smithloff
,
M.
and
M. E.
Fritz
.
The use of blade implants in a selected population of partially edentulous patients: a ten year report.
J Periodontol.
1982
.
53
:
413
418
.
15
Albrektsson
,
T.
,
G.
Zarb
,
P.
Worthington
, and
A. R.
Eriksson
.
The long term efficacy of currently used dental implants: a review and proposed criteria of success.
Int J Oral Maxillofac Implants.
1986
.
1
:
11
25
.
16
Branemark
,
P. I.
,
B. O.
Hansson
, and
R.
Adell
.
et al
.
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
Scand J Plast Reconstr Surg Suppl.
1977
.
16
:
1
132
.
17
Sonick
,
M.
,
J.
Abrahams
, and
R.
Faiella
.
A comparison of the accuracy of periapical, panoramic, and computerized tomographic radiographs in locating the mandibular nerve.
Int J Oral Maxillofac Implants.
1994
.
9
:
455
460
.
18
Frederiksen
,
N. L.
Diagnostic imaging in dental implantology.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod.
1995
.
80
:
540
554
.
19
Almog
,
D. M.
,
J. M.
Onufrak
,
K.
Hebel
, and
S. W.
Meitner
.
Comparison between planned prosthetic trajectory and residual bone trajectory using surgical guides and tomography: a pilot study.
J Oral Implantol.
1995
.
21
:
275
280
.
20
Almog
,
D. M.
and
R.
Sanchez
.
Correlation between planned prosthetic and residual bone trajectories in dental implants.
J Prosthet Dent.
1999
.
81
:
562
567
.
21
Almog
,
D. M.
,
E.
Torrado
, and
S. W.
Meitner
.
Fabrication of imaging and surgical guides for dental implants.
J Prosthet Dent.
2001
.
85
5
:
504
508
.
22
Almog
,
D. M.
,
E.
Torrado
,
S. W.
Meitner
,
M. E.
Moss
, and
F.
LaMar
.
Use of imaging guides in pre-implant tomography.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod.
2002
.
93
:
483
487
.
23
Parel
,
S. M.
and
R. G.
Triplett
.
Interactive imaging for implant planning, placement, and prosthesis construction.
J Oral Maxillofac Surg.
2004
.
62
9
:
41
47
.
24
Tyndall
,
A. A.
and
S. L.
Brooks
.
Selection criteria for dental implant site imaging: a position paper of the American Academy of Oral and Maxillofacial radiology.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod.
2000
.
89
5
:
630
637
.
25
White
,
S. C.
,
E. W.
Heslop
,
L. G.
Hollender
,
K. M.
Mosier
,
A.
Ruprecht
, and
M. K.
Shrout
.
American Academy of Oral and Maxillofacial Radiology, ad hoc Committee on Parameters of Care. Parameters of radiologic care: an official report of the American Academy of Oral and Maxillofacial Radiology.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod.
2001
.
91
5
:
498
511
.
26
Siessegger
,
M.
,
B. T.
Schneider
, and
R. A.
Mischkowski
.
et al
.
Use of an image-guided navigation system in dental implant surgery in anatomically complex operation sites.
J Craniomaxillofac Surg.
2001
.
29
5
:
276
281
.
27
Almog
,
D. M.
,
B. W.
Benson
,
L.
Wolfgang
,
N. L.
Frederiksen
, and
S. L.
Brooks
.
CT-based imaging and surgical guidance in oral implantology.
J Oral Implantol.
2006
.
32
1
:
14
18
.
28
Aranyarachkul
,
P.
,
J.
Caruso
, and
B.
Gantes
.
et al
.
Bone density assessments of dental implant sites: 2. Quantitative cone-beam computerized tomography.
Int J Oral Maxillofac Implants.
2005
.
20
3
:
416
424
.
29
Norton
,
M. R.
and
C.
Gamble
.
Bone classification: an objective scale of bone density using the computerized tomography scan.
Clin Oral Implants Res.
2001 Feb
.
12
1
:
79
84
.

Author notes

Dov M. Almog, DMD, is in private practice limited to prosthodontics and craniofacial diagnostic imaging in Rochester, New York. Dr. Almog is also an adjunct clinical associate professor in the Department of Oral Diagnostic Sciences at the University at Buffalo, School of Dental Medicine, Buffalo, New York. Address correspondence to Dr. Almog at 1960 Clinton Ave. South, Rochester, NY 14618 ([email protected]).

Shirl Lanni is a radiologic technologist at Craniofacial Digital Imaging, Rochester, New York.

Lynn W. Solomon, DDS, MS, is an assistant professor and director of oral radiology at Department of Oral Diagnostic Sciences, University at Buffalo School of Dental Medicine, Buffalo, New York.