Four commercial brands of chemically activated acrylic resin were compared through photoelastic analysis. Photoelastic resin blocks were made with 2 implants placed parallel to each other and 2 square transfer copings splinted. Both transfers were splinted with chemically activated acrylic resin: Dencrilay, Duralay I, Duralay II, and GC. Data were analyzed by 2-way analysis of variance and Tukey test (P < .05). Statistically significant differences were found among the 3 brands of chemically activated acrylic resin. Dencrilay showed greater dimensional alteration. Duralay I and GC are recommended for the transfer of the position of the multi-implants.

The main goal of fabricating implant-supported restorations is the production of superstructures that exhibit accurate fit when connected to multiple abutments.1,2  The requisite for obtaining such a fit is a precise impression. The adaptation precision, between prosthetic infrastructure and implant or tooth, is one of the great challenges of the oral rehabilitators. Particularly, the lack of passivity of the prosthetic devices has received great attention from researchers.39 

Several materials are involved in the execution of adaptation precision, among them, the chemically activated acrylic resin that is used frequently and that is susceptible to dimensional alterations.10,11  Assif et al10  investigated the accuracy of direct implant impression techniques with the use of various splinting materials and found that more accurate results were obtained by using techniques in which chemically activated acrylic resin or impression plaster was used as the splinting material.

Hsu et al12  and Herbst et al13  after evaluating the distortion of abutment position on the master cast, concluded that the volume of Duralay acrylic resin used to splint implant transfer copings is an insignificant factor in impression transfer accuracy. However, in the first part of this research report, we show that the resin volume interfered with the transfer process due to the larger amount of resin used. These results are in agreement with those of other studies.14 

Del Acqua et al15  compared the dimensional accuracy of 2 impression techniques: Duralay splinted impression copings and metal splinted impression copings for implant-supported prostheses. They used the same impression material, and it was suggested that a more accurate working cast can be fabricated using metal splinted impression copings.

Due to the controversial results, this article presents results of a photoelastic analysis comparing 4 commercial brands of chemically activated acrylic resins that are frequently used during the direct transfer technique of implants: Dencrilay, Duralay I, Duralay II, and GC Pattern.

A master acrylic model was fabricated to be used as matrix for the photoelastic models. The methodology is described in the first part of this report. Three rectangular photoelastic models were obtained according to the instructions of the manufacturer (Figure 1). All photoelastic blocks were evaluated with a circular polariscope to verify the lack of residual stress (type PJ300 optical comparator, Mitutoyo Mfg Co Mfg Ltd, Tokyo, Japan).

Figures 1–9.

Figure 1. Transfers positioned on the implants on the photoelastic model and work screws with torque of 10 N. Figures 2 and 3. Photoelastic response in areas AA' (left) and BB' (right) after period of 36 h with the Duralay I resin. Figures 4 and 5. Photoelastic response in areas AA' (left) and BB' (right) after period of 36 h with Duralay II resin. Figures 6 and 7. Photoelastic response in areas AA' (left) and BB' (right) after period of 36 h with GC resin. Figures 8 and 9. Photoelastic response in areas AA' (left) and BB' (right) after a period of 36 h with Dencrilay resin.

Figures 1–9.

Figure 1. Transfers positioned on the implants on the photoelastic model and work screws with torque of 10 N. Figures 2 and 3. Photoelastic response in areas AA' (left) and BB' (right) after period of 36 h with the Duralay I resin. Figures 4 and 5. Photoelastic response in areas AA' (left) and BB' (right) after period of 36 h with Duralay II resin. Figures 6 and 7. Photoelastic response in areas AA' (left) and BB' (right) after period of 36 h with GC resin. Figures 8 and 9. Photoelastic response in areas AA' (left) and BB' (right) after a period of 36 h with Dencrilay resin.

Close modal

The impression technique of implants with splintage with dental floss consists of interlacing the transfers with 20 cm of dental floss to which chemically activated acrylic resin is added. Four types of acrylic resins were tested: Dencrilay (Dencril, Com e Ind de Plásticos LTDA, Caieiras, SP, Brazil), Duralays I and II (Reliance Dental Mfg Co, Worth, Ill), and GC Pattern (G.C. América Inc, Tokyo, Japan). The amount of 0.8 g of chemically activated acrylic resin was inserted for each type of resin so that union of the transfers occurred. Before adding the resin on the dental floss, the model was positioned in the circular polariscope to guarantee that the dental floss had not induced tension on the transfers. After the indexation, the samples were observed in 4 time periods: 20 min, 3 h, 24 h, and 36 h.

During the photoelastic analysis, the Tardy method was used. Currently, this method is preferred over the other methods once auxiliary instruments are not required and the analyzer of the polariscope serves as a compensation device. Also, a precision of approximately 0.02 fringes can be reached16  (Figures 2 through 9).

Photoelasticity is mostly used in cases where mathematical methods become quite cumbersome to determine the stress distribution in a material. This stress analysis is based on the property that some transparent materials exhibit colorful patterns when submitted to loads and viewed with polarized light. This array of colored patterns is called isochromatic fringes. Unlike the analytical methods of stress determination, photoelasticity gives an accurate picture of stress distribution even around abrupt discontinuities in a material. Studies using photoelastic analysis have been thoroughly conducted to determine the stress distribution around natural teeth, on abutments of removable partial prosthesis and fixed partial prosthesis, and around endosseous implants under complete dentures, and to determine stresses around endosseous implants supporting fixed prosthesis.17 

The relationship between the sequence of the fringes (N) and their distances (mm) to the point of origin was set (Table 1). The tables were imported into MATLAB software (1994–2007, The MathWorks, Inc, Natick, Mass) and Cartesian graphs were created. The distance between the positions of the fringes is represented in the x-axis and their sequences in the y-axis.

Table 1

Points evaluated in area AA' and their respective fringe order with Dencrilay resin after 36 h

Points evaluated in area AA' and their respective fringe order with Dencrilay resin after 36 h
Points evaluated in area AA' and their respective fringe order with Dencrilay resin after 36 h

The distortion energy (E) distributed in the area corresponding to each of the two analyzed lines was obtained by calculating the area below each curve of the graphs representative of the relation fringe order (N) and distance from the point of origin of the load (Figure 10). The distortion energy per unit of volume represents the unit of dimensional tension, known as U (newton per square millimeter [N/m2] or kilogram-force/square millimeter [kgf/mm2]).18  After calculating these energies, statistical analysis was conducted using Friedman and Wilcoxon tests (P < .05).

Figure 10.

Area AA' with Dencrilay resin after 36 h (E = 0.384 kgf/mm2).

Figure 10.

Area AA' with Dencrilay resin after 36 h (E = 0.384 kgf/mm2).

Close modal

The E values for AA' and BB' areas obtained for the resins Dencrilay, Duralay I, and GC Pattern are shown in Table 2. Figures 2 through 9 present the photoelastic responses in 36 h. The significance level was established at .05 in a bilateral test.

Table 2

Distortion energy (E), evaluated at 4 times, for dental floss technique in areas AA' and BB'

Distortion energy (E), evaluated at 4 times, for dental floss technique in areas AA' and BB'
Distortion energy (E), evaluated at 4 times, for dental floss technique in areas AA' and BB'

Analysis of variance and Tukey test were applied to verify statistically significant differences among values of the energies in AB areas for all resins used (Dencrilay, Duralay I, Duralay II, and GC) during the dental floss technique (Table 3 and 4).

Table 3

Analysis of variance and Tukey test results: F values and probabilities for the values of AB obtained for the acrylic resins

Analysis of variance and Tukey test results: F values and probabilities for the values of AB obtained for the acrylic resins
Analysis of variance and Tukey test results: F values and probabilities for the values of AB obtained for the acrylic resins
Table 4

Tukey test results for dental floss technique

Tukey test results for dental floss technique
Tukey test results for dental floss technique

Table 4 shows that the values obtained with Dencrilay resin were significantly higher than the values obtained with the Duralay I and GC resins; Duralay II presented intermediate values. However, no statistically significant differences were found between Dencrilay and Duralay II resins, as well as among Duralay I, Duralay II and GC resins (Table 4).

The best impression technique for multiple implant prostheses has not yet been identified. The accurate transference of the implants from the dental arch to the definite cast is fundamental to ensure the absence, or at least a decrease, of misfit in the final prosthetic device.47  Abutment position distortion has often accompanied transfer impression techniques. The impression materials and the technique used for the transfer of the position of the implants ensure an excellent adaptation of the prosthetic components.16 

The impression technique that uses dental floss as a framework so that the chemically activated acrylic resin can splint the transfers is applied broadly in clinical practice.3,12,13,19,20  In this study, 4 acrylic resins were used in this technique: Dencrilay, Duralay I, Duralay II, and GC Pattern. A comparison, via photoelastic analysis, revealed significantly different dimensional alterations among these resins. Tension was observed in all groups tested, indicating that the dental floss technique is not appropriate for splinting during the impression of implants.

Because this method involves larger resin volumes, it is more susceptible to distortions than other direct impression techniques, such as metallic sticks.8,19  Fillho et al21  compared 4 splinting techniques for impression copings of implants: direct technique with square copings without union in open trays; square copings splinted with dental floss and autopolymerizing acrylic resin; square copings splinted with dental floss and autopolymerizing acrylic resin, sectioning, and splinting again with autopolymerizing acrylic resins; and square copings splinted with prefabricated acrylic resin bar. They also concluded that the square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated.

However, if dental floss framework is the method of choice, materials that result in less distortions are requested. Autopolymerizing acrylic resins are used a great deal in dental practice, and for splinting during impression techniques, Duralay I and GC Pattern are preferred because they showed less tension based on the findings of this study.

Under the conditions of this study, some conclusions can be drawn: Dencrilay resin showed greater dimensional alterations compared with the others acrylic resins; Duralay I and GC Pattern resins are suggested to be more appropriate for splinted impression copings of multi-implant prostheses. The dental floss technique for splinting and the use of chemically activated acrylic resin are not recommended to splinted impression copings of multi-implant prostheses, because all samples showed tension on the impression copings.

We are grateful to Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES), Brazil, for the student scholarship. This study was supported by Sistema de Implantes Nacionais (SIN), São Paulo, SP, Brazil, Reliance Dental, and G.C. America.

1
Adell
R
,
Lekholm
U
,
Rockler
B
,
Brånemark
P-I. A
15-year study of osseointegrated implants in the treatment of edentulous jaw
.
Int J Oral Surg
.
1981
:
10
:
387
416
.
2
Zarb
GA
,
Schmitt
A
.
The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: problems and complications encountered
.
J Prosthet Dent
.
1990
;
64
:
185
194
.
3
Philips
KM
,
Nicholls
JI
,
Ma
T
,
Rubenstein
J
.
The accuracy of three implant impression techniques: a three-dimensional analysis
.
Int J Oral Maxillofac Implants
.
1994
;
9
:
533
540
.
4
Takahashi
J
,
Kitahara
K
,
Teraoka
F
,
Kubo
F
.
Resin pattern material with low polymerization shrinkage
.
Int J Prosthodont
.
1999
;
12
:
325
329
.
5
Dumbrigue
HB
,
Gurun
DC
,
Javid
NS
.
Prefabricated acrylic resin bars for splinting implant transfer copings
.
J Prosthet Dent
.
2000
;
84
:
108
110
.
6
Vigolo
P
,
Majzoub
Z
,
Cordioli
G
.
Evaluation of the accuracy of three techniques used for multiple implant abutment impression
.
J Prosthet Dent
.
2003
;
89
:
186
192
.
7
Vigolo
P
,
Fonzi
F
,
Majzoub
Z
,
Cordioli
G
.
An evaluation of impression techniques for multiple internal connection implant prostheses
.
J Prosthet Dent
.
2004
;
92
:
470
476
.
8
Naconecy
MM
,
Teixeira
ER
,
Shinkai
RSA
,
Frasca
LCF
,
Cervieiri
A
.
Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments
.
Int J Oral Maxillofac Implants
.
2004
;
19
:
192
198
.
9
Cabal
LM
,
Guedes
CG
.
Comparative analysis of 4 impression techniques for implants
.
Implant Dent
.
2007
;
16
:
187
194
.
10
Assif
D
,
Nissan
J
,
Varsano
I
,
Singer
A
.
Accuracy of implant impression splinted technique: effect of splinting material
.
Int J Oral Maxillofac Implants
.
1999
;
14
:
885
888
.
11
Mojon
P
,
Oberholzer
JP
,
Meyer
JM
,
Belser
UC
.
Polymerization shrinkage of index and pattern acrylic resins
.
J Prosthet Dent
.
1990
;
64
:
684
688
.
12
Hsu
C-C
,
Millstein
PL
,
Stein
RS
.
A comparative analysis of the accuracy of implant transfer techniques
.
J Prosthet Dent
.
1993
;
69
:
588
593
.
13
Herbst
D
,
Nel
JC
,
Driessen
CH
,
Becker
PJ
.
Evaluation of impression accuracy for osseointegrated implant supported superstructures
.
J Prosthet Dent
.
2000
;
83
:
555
561
.
14
Spector
MR
,
Donovan
TE
,
Nicholls
JI
.
An evaluation of impression techniques for osseointegrated implants
.
J Prosthet Dent
.
1990
;
63
:
444
447
.
15
Del Acqua
MA
,
Chavez
AM
,
Castanharo
SM
,
Compagnoni
MA
,
Mollo Fde A Jr. The effect of splint material rigidity in implant impression techniques
.
Int J Oral Maxillofac Implants
.
2010
;
25
:
1153
1158
.
16
Dally
JW
,
Riley
WF
.
Experimental Stress Analysis
.
New York, NY
:
McGraw-Hill
,
1991
:
424
506
.
17
Caputo
AA
,
Standlee
JP
.
Biomechanics in Clinical Dentistry
;
Chicago, Ill
:
Quintessence
;
1987
.
18
Osakada
K
.
History of plasticity and metal forming analysis
.
J Mat Proc Tech
.
2010
;
210
:
1436
1454
.
19
Assunção
WG
,
Gennari-Filho
H
,
Zaniquelli
O
.
Evaluation of transfer impressions for osseointegrated implants at various angulations
.
Implant Dent
.
2004
;
13
:
358
366
.
20
Albrektsson
T
,
Zarb
GA
.
Clinical results of a 24-team multicenter study of the Branemark implant
.
In
:
Branemark Osseointegrated Implant
.
Chicago, Ill
:
Quintessence;
1989
:
165
195
.
21
Filho
HG
,
Mazaro
JV
,
Vedovatto
E
,
Assunção
WG
,
Santos
PH
.
Accuracy of impression techniques for implants. Part 2 - comparison of splinting techniques
.
J Prosthodont
.
2009
;
18
:
172
176
.