The aim of this study was to evaluate the effects of bruxing forces on implants configured under 2 different occlusal schemes by dynamic finite element analysis. A main model consisting of a 5-unit fixed partial denture supported by 3 implants was simulated with bone, implants, and superstructures. All calculations were made individually for each component, namely porcelain crowns, abutments, abutment screws, implants, and bone. Maximum stresses were found in the group-function occlusion. Group-function loading may result excess stresses on the components compared with canine-guidance loading. According to the results of this study, use of canine guidance is encouraged in bruxers with implant-supported prostheses.

Bruxism is defined as a parafunctional habit occurring during sleep or while awake that is characterized by grinding and/or clenching of the teeth.14  This parafunction may provoke an increase in muscular forces, and the overloaded structures may lead to temporomandibular dysfunctions, periodontal problems, wear on teeth, and failure of restorations on natural teeth and oral implants.1,59  Such negative outcomes may also cause early wear or fracture of implant components.10,11  The so-called bending forces and overload may cause deleterious effects on implants, supporting alveolar bone, and the prostheses they support.10  Although this parafunctional habit is considered a critical factor in implant success, there is no scientific proof that bruxism is a definite contraindication for implant treatment provided that attention has been paid to some critical load control factors.1113  Occlusion may dramatically influence the effect of bruxism in patients with implant-supported prostheses.10,14 

Implant occlusion principles mostly agree with occlusal principles in natural tooth restorations.15  Yet the mechanical effects of the occlusal concepts on oral implant components have not been clearly shown in the literature. Therefore, the aim of the present study is to compare the effects of canine guidance and group-function occlusal concepts on implant loading under heavy bruxing forces using a 3-dimensional dynamic finite element analysis method.

Models

A posterior mandibular segment with a 5-unit fixed partial denture supported by 3 endosseous cylindric implants between canine and second molar area was simulated with a 3-dimensional finite element model (Figure 1). The CATIA design program (Dassault Systèmes SA, Vélizy-Villacoublay, France) was used to geometric modeling. The implants were assumed to be located in the canine, second premolar, and second molar regions. All implants were considered to be completely osseointegrated with the bone. Implant diameters were 3.5 mm for canine and premolar implants and 4 mm for molar implant; implant length was 10 mm. The mandible model was 30 mm high. Trabecular bone width was 13 mm buccolingually, and cortical bone width was 1.5 mm. Cortical and trabecular bone, implants, abutments, abutment screws, and bridge were then transferred into the mathematical model. The MSC Marc&Patran finite element analysis (FEA) program (MSC Software, Santa Ana, Calif) was used to generate the mathematical model and to make stress and strain calculations. All the calculations were made individually for each component, namely porcelain crowns, abutments, abutment screws, implants, and bone.

Figures 1–3.

Figure 1. Geometric model. Figure 2. (a) Mathematical model boundary conditions under canine guidance occlusal load. (b) Mathematical model boundary conditions under group-function occlusal load. Figure 3. (a) Distribution of maximal displacements under canine-guidance loading. (b) Distribution of maximal displacements under group-function loading.

Figures 1–3.

Figure 1. Geometric model. Figure 2. (a) Mathematical model boundary conditions under canine guidance occlusal load. (b) Mathematical model boundary conditions under group-function occlusal load. Figure 3. (a) Distribution of maximal displacements under canine-guidance loading. (b) Distribution of maximal displacements under group-function loading.

Close modal

Material properties

All materials used in the models were considered to be isotropic, homogeneous, and linearly elastic. The assumed materials for the components are porcelain for the bridge and titanium for implant, abutment, and abutment screws. The Young's modulus of elasticity and Poisson's ratio values for each material used in the present study are presented in Table 1.

Table 1

Material properties

Material properties
Material properties

Elements and nodes

The same model was used for both canine-guidance and group-function loading conditions. Tetrahedric isoparametric quadratic elements with 10 nodes were used for modeling each component. The mathematical model had 49 299 elements and 81 338 nodes.

Boundary conditions and loading

The model was restrained in all 3 degrees of freedom on the mesial and distal border surfaces of the bone. Two different loading conditions simulating canine guidance and group-function occlusion were applied to the model. A 1000N oblique load representing bruxism forces was applied to the model in total at a 30° inclination.16  To simulate the bruxing patterns appropriately, loads were applied slowly for 10 seconds. The unsteady characteristic of the bruxing event was simulated after surveying many studies that investigated electromyogram data and time-dependent force levels.1727 

For group-function occlusion the load was divided to the crowns with a proportion of Fcanine:Fpremolar:Fmolar = 1:1:2.2830  For canine guidance the load was decreased to 250N to simulate the clinical situation more appropriately, considering the fact that there will be no constructions in two-thirds of the masseter and temporal muscles during canine-only contact position.29,30  Loading and boundary conditions for both occlusal concepts are shown in Figure 2a and b.

After loading, maximum von Mises/principle stress values for each component, as well as deformation of the entire system were recorded for both loading conditions (ie, canine guidance and group function).

Deformation (Maximum displacement values)

In both loading conditions the maximal displacement values were pronounced at the points at which the load was applied. Therefore, when the force was applied on the canine crown, the highest recorded maximum displacements were located around the tip of the canine crown, whereas the applied group-function loading resulted in higher displacements around the buccal cusps of the first molar crown (Figure 3a and b). There were large differences in these recorded values (0.08 mm and 0.339 mm for canine guidance and group function, respectively). This greater than 3 times difference in displacement values between 2 occlusal concepts shows that there is a potential risk of more deformation in crowns when group-function occlusal guidance is used.

Maximal principle and von Mises stresses

Maximal principle stresses were calculated for brittle materials, such as porcelain and bone, and von Mises stresses were recorded for ductile materials, such as implants, abutments, and abutment screws that contain titanium. The maximal principle stresses generated at the crowns were located around the points where forces had been applied (191.61 MPa and 559.21 MPa for canine guidance and group function, respectively). The highest von Mises stresses were observed around the buccal and lingual neck portions of the implants (canine guidance = 199.20 MPa; group function = 926.80 MPa) and abutment screws (canine guidance = 142.89 MPa; group function = 574.65 MPa), and the maximum stresses in abutments were located at the implant-abutment interface (canine guidance = 382.71 MPa; group function = 1310.33 MPa). The stress values registered in cortical bone were higher than the values in trabecular bone. All recorded stress values for each component were higher in group-function loading (Figures 4 through 6; Table 2).

Figure 4.

Distribution of maximal stresses in components under canine-guidance loading.

Figure 4.

Distribution of maximal stresses in components under canine-guidance loading.

Close modal
Figure 6.

Distribution of stresses under both occlusal guidance types for (a) bone, (b) implants, (c) abutment screws, (d) abutments, and (e) crowns.

Figure 6.

Distribution of stresses under both occlusal guidance types for (a) bone, (b) implants, (c) abutment screws, (d) abutments, and (e) crowns.

Close modal
Table 2

Maximal stress values under canine-guidance and group-function loading (MpA)

Maximal stress values under canine-guidance and group-function loading (MpA)
Maximal stress values under canine-guidance and group-function loading (MpA)

In this study the effects of bruxism forces applied under 2 occlusal concepts on bone, implants, and superstructures were investigated using 3-dimensional dynamic FEA. The properties of the materials were similar to those described in previous studies derived from actual physical measures.16,3134  The model contained a 5-unit bridge in the posterior segment, rather than a single crown. This design is preferred for showing the contribution of the effects of forces on different areas of a bridge restoration.

The aim of the present study is to predict and compare the stress distributions around bone and implant structures rather than obtain numeric results. Although FEA is one of the most preferred in vitro stress analysis methods, the validity of the results obtained by this method are assumed to be qualitative rather than quantitative.33  This is because the anisotropic and nonhomogeneous properties of the bone and related structures cannot be simulated.3335  Nevertheless, FEA is a convenient method to compare stresses and strains in different circumstances, and its validity has been proven by many strain gauge measurement studies.3639 

Oral implants are exposed to different loads in all directions in the mouth and this dynamic nature of the loading conditions should be taken into account when restoring with a fixed prosthesis. In this study, 2 different oblique loads were applied on the models dynamically with the intention of simulating a bruxing event. In most FEA studies in dentistry impact load has been simulated,4043  although this type of loading may fail to adequately simulate parafunctional loads, such as bruxing forces.44  According to Zhang and Chen,45  dynamic loading results in higher stresses compared with static loading.

The differential bite forces in the dental arch were also taken into consideration in the present study. It is known that bite forces increase in posterior regions. Additionally, when posterior contact is lacking, two thirds of the masseter and temporalis muscle fibers remain relaxed.29  Thus, 2 different force magnitudes have been used for presenting canine-guidance and group-function occlusion.

Although Ishigaki et al46  claimed in their comparative FEA study simulating chewing events that they found similar stress values in tooth and implants, the effect of bruxing forces on bone may differ depending on the lack or existence of the periodontal ligament.

Occlusion is one of the most important factors that need to be evaluated carefully before implant treatment.47,48  It is especially crucial in patients with bruxing habits because of the risk of overload.13  Perel49  stated that nocturnal parafunctional habits may be controlled by use of a nightguard. Although nightguards may ameliorate the overload during sleep, with many patients risk of overload is caused by diurnal bruxism. Therefore, other stress-relief factors should also be taken into consideration. It is recommended to give a canine guidance in fixed partial dentures, especially in patients with parafunctional habits.29,50,51  Yet in some clinical situations, such as when there are compromised canines or single implants on canine tooth, there may be a need for support of additional posterior contacts.50,51 

The results of this study show that there is an extreme increase in stresses when the bridge is loaded under group function rather than canine guidance. This result is in accordance with previous clinical studies comparing occlusal loading concepts.52,53  It is also known that restorations on heavy bruxers with canine guidance type of occlusion may become a group function because of the excessive attrition on canine restorations.54  Therefore, it is very important to check these patients for occlusion in regular follow-ups.

Stress locations were similar for both occlusal guidance types, and they mostly occurred around the neck portions of the implants and abutment screws and around the cortical bone-implant interface. Akça and İplikçioğlu55  also found high stress values at the cortical bone around the cervical portion of implants. They concluded that the micromovement of the system is the reason for the high stress values, unlike with natural dentition, where the tooth moves separately and transmits forces through the periodontal ligament.

The main limitation of this study is the lack of full simulation of functional movements during a chewing activity via FEA. Thus, the results should be evaluated for comparison of 2 occlusal concepts rather than considering the stress values as definitive results. This study may be followed by clinical studies that compare the effects of these occlusal concepts in vivo.

In this study, it was concluded that

  • the stresses in implants, abutments, and abutment screws mainly concentrate around the neck portions of the components.

  • in an implant-retained posterior fixed partial denture and where bruxism exists, group function loading may result in excess stresses on the components compared with canine guidance loading. The results of this in silico study should be confirmed by further longitudinal clinical studies to reveal the potential impact of bruxing on implants and related prostheses.

Abbreviation

FEA

finite element analysis

Figure 5.

Distribution of maximal stresses in components under group-function loading.

Figure 5.

Distribution of maximal stresses in components under group-function loading.

Close modal

The present work was supported by the Research Fund of Istanbul University. Project No. 3708.

1
Basic
V
,
Mehulic
K
.
Bruxism: an unsolved problem in dental medicine
.
Acta Stomat Croat
.
2004
;
38
:
93
96
.
2
Faulkner
KDB
.
Bruxism: a review of the literature. Part I
.
Aust Dent J
.
1990
;
35
:
266
276
.
3
Lavigne
GJ
,
Khoury
S
,
Abe
S
,
Yamaguchi
T
,
Raphael
K
.
Bruxism physiology and pathology: an overview for clinicians
.
J Oral Rehabil
.
2008
;
35
:
476
494
.
4
Nadler
SC:
Bruxism, a classification: a critical review
.
J Am Dent Assoc
.
1957
;
54
:
615
622
.
5
Ahlberg
J
,
Savolainen
A
,
Rantala
M
,
Lindholm
H
,
Kononen
M
.
Reported bruxism and biopsychosocial symptoms: a longitudinal study
.
Community Dent Oral Epidemiol
.
2004
;
32
:
307
311
.
6
Attanasio
R
.
Nocturnal bruxism and its clinical management
.
Dent Clin North Am
.
1991
;
35
:
245
252
.
7
Attanasio
R
.
An overview of bruxism and its management
.
Dent Clin North Am
.
1997
;
41
:
229
241
.
8
Glaros
AG
,
Rao
SM
.
Bruxism: a critical review
.
Psychol Bull
.
1977
;
34
:
767
.
9
Klineberg
I
.
Bruxism: aetiology, clinical signs and symptoms
.
Aust Prosthodont J
.
1994
;
8
:
9
17
.
10
Rangert
B
,
Krogh
PH
,
Langer
B
,
Van Roekel
N
.
Bending overload and implant fracture: a retrospective clinical analysis
.
Int J Oral Maxillofac Implants
.
1995
;
10
:
326
334
.
11
Lobbezoo
F
,
Brouwers
JEIG
,
Cune
MS
,
Naeije
M
.
Dental implants in patients with bruxing habits
.
J Oral Rehabil
.
2006
;
33
:
152
159
.
12
Lobbezoo
F
,
van der Zaag
J
,
Naeije
M
.
Bruxism: its multiple causes and its effects on dental implants—an updated review
.
J Oral Rehabil
.
2006
;
33
:
293
300
.
13
Misch
CE:
The effect of bruxism on treatment planning for dental implants
.
Dent Today
.
2002
;
21
:
76
81
.
14
Conrad
HJ
,
Schulte
JK
,
Vallee
MC
.
Fractures related to occlusal overload with single posterior implants: a clinical report
.
J Prosthet Dent
.
2008
;
99
:
251
256
.
15
Carlsson
GE
.
Dental occlusion: modern concepts and their application in implant prosthodontics
.
Odontology
.
2009
;
97
:
8
17
.
16
Juodzbalys
G
,
Kubilius
R
,
Eidukynas
V
,
Raustia
AM
.
Stress distribution in bone: single-unit implant prostheses veneered with porcelain or a new composite material
.
Implant Dent
.
2005
;
14
:
166
175
.
17
Amemori
Y
,
Yamashita
S
,
Ai
M
,
Shinoda
H
,
Sato
M
,
Takahashi
J
.
Influence of nocturnal bruxism on the stomatognathic system. Part I: a new device for measuring mandibular movements during sleep
.
J Oral Rehabil
.
2001
;
28
:
943
949
.
18
Baba
K
,
Clark
GT
,
Watanabe
T
,
Ohyama
T
.
Bruxism force detection by a piezoelectric film-based recording device in sleeping humans
.
J Orofac Pain
.
2003
;
17
:
58
64
.
19
Dejak
B
,
Mlotkowski
A
,
Romanowicz
M
.
Finite element analysis of mechanism of cervical lesion formation in simulated molars during mastication and parafunction
.
J Prosthet Dent
.
2005
;
94
:
520
529
.
20
Gallo
LM
,
Gross
SS
,
Palla
S
.
Nocturnal masseter EMG activity of healthy subjects in a natural environment
.
J Dent Res
.
1999
;
78
:
1436
1444
.
21
Lavigne
GJ
,
Rompré
PH
,
Montplaisir
JY
.
Sleep bruxism: validity of clinical research diagnostic criteria in a controlled polysomnographic study
.
J Dent Res
.
1996
;
75
:
546
552
.
22
Macaluso
GM
,
Guerra
P
,
Di Giovanni
G
,
Boselli
M
,
Parrino
L
,
Terzano
MG
.
Sleep bruxism is a disorder related to periodic arousals during sleep
.
J Dent Res
.
1998
;
77
:
565
573
.
23
Mericske-Stern
R
,
Assal
P
,
Buergin
W
.
Simultaneous force measurements in 3 dimensions on oral endosseous implants in vitro and in vivo. A methodological study
.
Clin Oral Implants Res
.
1996
;
7
:
378
386
.
24
Onodera
K
,
Kawagoe
T
,
Sasaguri
K
,
Protacio-Quismundo
C
,
Sato
S
.
The use of a bruxchecker in the evaluation of different grinding patterns during sleep bruxism
.
Cranio
.
2006
;
24
:
292
299
.
25
Reding
GR
,
Zepelin
H
,
Robinson
JE
Jr,
Zimmerman
SO
,
Smith
VH
.
Nocturnal teeth-grinding: all-night psychophysiologic studies
.
J Dent Res
.
1968
;
47
:
786
797
.
26
Wichelhaus
A
,
Hüffmeier
S
,
Sander
FG
.
Dynamic functional force measurements on an anterior bite plane during the night
.
J Orofac Orthop
.
2003
;
64
:
417
425
.
27
Yoshimi
H
,
Sasaguri
K
,
Tamaki
K
,
Sato
S
.
Identification of the occurrence and pattern of masseter muscle activities during sleep using EMG and accelerometer systems
.
Head Face Med
.
2009
;
11
;
5
7
.
28
Kumagai
H
,
Suzuki
T
,
Hamada
T
,
Sondang
P
,
Fujitani
M
,
Nikawa
H
.
Occlusal force distribution on the dental arch during various levels of clenching
.
J Oral Rehabil
.
1999
;
26
:
932
935
.
29
Misch
CE
.
Dental Implant Prosthetics
.
St Louis, Mo
:
Elsevier Mosby;
2005
.
30
Misch
CE
.
Key implant positions: treatment planning using the canine and first molar rules
.
Dent Today
.
2009
;
28
:
66
71
.
31
Çiftçi
Y
,
Canay
S
.
The effect of veneering materials on stress distribution in implant-supported fixed prosthetic restorations
.
Int J Oral Maxillofac Implants
.
2000
;
15
:
571
582
.
32
Huang
HL
,
Chang
CH
,
Hsu
JT
,
Fallgatter
AM
,
Ko
CC
.
Comparison of implant body designs and threaded designs of dental implants: a 3-dimensional finite element analysis
.
Int J Oral Maxillofac Implants
.
2007
;
22
:
551
562
.
33
Stegaroiu
R
,
Kusakari
H
,
Nishiyama
S
,
Miyakawa
O
.
Influence of prosthesis material on stress distribution in bone and implant: a 3-dimensional finite element analysis
.
Int J Oral Maxillofac Implants
.
1998
;
13
:
781
790
.
34
Geng
JP
,
Tan
KB
,
Liu
GR
.
Application of finite element analysis in implant dentistry: a review of the literature
.
J Prosthet Dent
.
2001
;
85
:
585
598
.
35
Wakabayashi
N
,
Ona
M
,
Suzuki
T
,
Igarashi
Y
.
Nonlinear finite element analyses: advances and challenges in dental applications
.
J Dent
.
2008
;
36
:
463
471
.
36
Eser
A
,
Akça
K
,
Eckert
S
,
Cehreli
MC
.
Nonlinear finite element analysis versus ex vivo strain gauge measurements on immediately loaded implants
.
Int J Oral Maxillofac Implants
.
2009
;
24
:
439
446
.
37
İplikçioğlu
H
,
Akça
K
,
Çehreli
MC
,
Şahin
S
.
Comparison of non-linear finite element stress analysis with in vitro strain gauge measurements on a Morse taper implant
.
Int J Oral Maxillofac Implants
.
2003
;
18
:
258
265
.
38
Karl
M
,
Dickinson
A
,
Holst
S
,
Holst
A
.
Biomechanical methods applied in dentistry: a comparative overview of photoelastic examinations, strain gauge measurements, finite element analysis and three-dimensional deformation analysis
.
Eur J Prosthodont Restor Dent
.
2009
;
17
:
50
57
.
39
Tajima
K
,
Chen
KK
,
Takahashi
N
,
Noda
N
,
Nagamatsu
Y
,
Kakigawa
H
.
Three-dimensional finite element modeling from CT images of tooth and its validation
.
Dent Mater J
.
2009
;
28
:
219
226
.
40
Dalkiz
M
,
Zor
M
,
Aykul
H
,
Toparli
M
,
Aksoy
S
.
The three-dimensional finite element analysis of fixed bridge restoration supported by the combination of teeth and osseointegrated implants
.
Implant Dent
.
2002
;
11
:
293
300
.
41
Yokoyama
S
,
Wakabayashi
N
,
Shiota
M
,
Ohyama
T
.
The influence of implant location and length on stress distribution for three-unit implant-supported posterior cantilever fixed partial dentures
.
J Prosthet Dent
.
2004
;
91
:
234
240
.
42
Bevilacqua
M
,
Tealdo
T
,
Pera
F
,
et al
.
Three-dimensional finite element analysis of load transmission using different implant inclinations and cantilever lengths
.
Int J Prosthodont
.
2008
;
21
:
539
542
.
43
Sevimay
M
,
Turhan
F
,
Kiliçarslan
MA
,
Eskitascioglu
G
.
Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown
.
J Prosthet Dent
.
2005
;
93
:
227
234
.
44
Kayabaşı
O
,
Yüzbaşıoğlu
E
,
Erzincanlı
F
.
Static, dynamic and fatigue behaviors of dental implant using finite element method
.
Adv Eng Softw
.
2006
;
37
:
649
658
.
45
Zhang
JK
,
Chen
ZQ
.
The study of effects of changes of the elastic modulus of the materials substitute to human hard tissues on the mechanical state in the implant-bone interface by three-dimensional anisotropic finite element analysis
.
Hua Xi Kou Qiang Yi Xue Za Zhi
.
1998
;
16
:
274
278
.
46
Ishigaki
S
,
Nakano
T
,
Yamada
S
,
Nakamura
T
,
Takashima
F
.
Biomechanical stress in bone surrounding an implant under simulated chewing
.
Clin Oral Implants Res
.
2003
;
14
:
97
102
.
47
Morneburg
TR
,
Pröschel
PA
.
In vivo forces on implants influenced by occlusal scheme and food consistency
.
Int J Prosthodont
.
2003
;
16
:
481
486
.
48
Saba
S
.
Occlusal stability in implant prosthodontics—clinical factors to consider before implant placement
.
J Can Dent Assoc
.
2001
;
67
:
522
526
.
49
Perel
ML
.
Parafunctional habits, nightguards, and root form implants
.
Implant Dent
.
1994
;
3
:
261
263
.
50
Kim
Y
,
Oh
TJ
,
Misch
CE
,
Wang
HL
.
Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale
.
Clin Oral Implants Res
.
2005
;
16
:
26
35
.
51
Chapman
RJ
.
Principles of occlusion for implant prostheses: guidelines for position, timing, and force of occlusal contacts
.
Quintessence Int
.
1989
;
20
:
473
480
.
52
Tokiwa
O
,
Park
BK
,
Takezawa
Y
,
Takahashi
Y
,
Sasaguri
K
,
Sato
S
.
Relationship of tooth grinding pattern during sleep bruxism and dental status
.
Cranio
.
2008
;
26
:
287
293
.
53
Williams
EH
,
Lundquist
DO
.
Anterior guidance: its effect on electromyographic activity of the temporal and masseter muscles
.
J Prosthet Dent
.
1983
;
49
:
816
823
.
54
Christensen
GJ
.
Now is the time to observe and treat dental occlusion
.
J Am Dent Assoc
.
2001
;
132
:
100
102
.
55
Akça
K
,
Iplikçioğlu
H
.
Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis
.
Implant Dent
.
2001
;
10
:
238
245
.