The purpose of this study is to estimate the magnitude of crestal bone loss and to identify factors associated with changes in crestal bone height following placement of dental implants. This was a retrospective cohort study, consisting of a sample derived from the population of patients who had at least 1 dental implant placed in a community practice over a 10-year period. A total of 11 predictor variables were grouped into demographic, related health status, anatomic, implant-specific, and operative categories. The primary outcome variable was a change in crestal bone height (mm) over the course of follow-up. The secondary outcome variable was crestal bone loss at 1 year grouped into 2 categories (bone loss >1.5 mm and ≤1.5 mm). Univariate and multivariate regression mixed-effects models were developed to identify variables associated with crestal bone level changes over time. P values ≤.05 were considered statistically significant. The study sample was composed of 85 subjects who received 148 implants. The mean change of the crestal bone was −2.1 ± 1.5 mm (range = −12.5 to 0.5 mm; median = −1.77 mm). In the multivariate model, none of the variables studied were statistically associated with mean crestal bone loss. Among 84 (66.1%) implants with bone loss >1.5 mm within 1 year, no variables were associated with bone loss in the multivariate model. Of the 11 predictor variables evaluated in this study, none were statistically significant with regard to an increased risk for crestal bone loss or for excessive bone loss within the first year after implant placement.

The factors associated with a prognosis of dental implants and implant failure have been studied immensely.15  Crestal bone loss less than 1.5 mm in the first year and subsequent annual bone level changes of 0.2 mm at the implant and bone interface are generally accepted as within the limits of a normal physiologic process.6,7  Although this loss of crestal bone height around the implant during the early healing phase has been considered an acceptable physiologic change, continued loss of crestal bone height following osseointegration may result in increased mobility and subsequent failure.8 

Factors thought to influence the number of changes in crestal bone height after implant placement include delayed vs immediate implant placement, staging, timing of implant loading, requirement of bone graft at the implant site, presence of infection, medical conditions that compromise wound healing, smoking, status of oral hygiene, location of implant placement, and size of the implants.15  Other mechanical factors such as periosteum elevation during surgery, overheating of the instrument resulting in osteonecrosis, occlusal trauma, cantilever effect, and physiologic bone remodeling from inflammatory process and plaque accumulation have been also suggested.9 

The purpose of this study was to estimate the magnitude of crestal bone loss at 1 year following dental implant placement and to identify factors associated with increased bone loss. The investigators hypothesized that there was a set of discrete, identifiable factors associated with increased levels of bone loss, and these variables may be manipulated by clinicians to enhance outcomes. The specific aims were (1) to enroll a cohort of subjects who had at least 1 dental implant placed, (2) to measure crestal bone heights before and following implant placement, and (3) to develop and implement a multivariate model to identify variables associated with bone loss.

Study design/sample

This was a retrospective cohort study. The investigators enrolled a cohort of subjects who underwent dental implant placement (Nobel Replace Select, Nobel Biocare, Mahwah, NJ) between January 1997 and September 2006 in a community oral and maxillofacial surgical practice. Every implant was placed in standard fashion using a full-thickness mucoperiosteal flap. Every patient received a preoperative dose of antibiotics. Patients were included as subjects if they had at least 1 dental implant placed during the study period and had complete follow-up data, including clinical and radiographic assessments. Patients were excluded from the study if their charts were missing or had incomplete data. This retrospective cohort study with review of charts was approved by the institutional review board. Also, this study was conducted in accordance with the ethical principles of the World Medical Association Declaration of Helsinki.

Study variables

Predictor variables

The predictor variables were composed of a set of heterogeneous variables classified as demographic (age and sex), related health status (smoking history and American Society of Anesthesiology Classification [ASA] status), anatomic variables (implant location, ie, maxilla vs mandible and anterior vs posterior), implant-specific (implant diameter and length), and operative factors (loading: placement of a crown portion prosthesis at the time of an implant placement to function; immediate implant: placement after extracting a tooth or preexisting implant; staging: placement of healing abutment exposed through the gingiva vs healing cap buried under the gingiva; dentoalveolar reconstruction procedures [DRPs], eg, sinus lift, ridge augmentation).

Outcome variables

The primary outcome variable was a change in crestal bone height over the course of follow-up. The secondary outcome variable was crestal bone loss at 1 year, and it was coded as bone loss ≤1.5 mm and bone loss >1.5 mm. Changes in crestal bone height were estimated by measuring radiographs corrected for magnification by calculating a ratio of the actual implant length divided by the measured radiographic implant length (Figure). The comparison was made between the first postoperative radiograph and the latest follow-up radiograph. The corrected crestal bone level = actual implant length/measured implant length × measured crestal bone height. Measurements were made at the mesial and distal crestal bone levels. The lowest crestal height measurement was used for analyses.

Figure.

Radiographic measurement of crestal bone loss changes.

Figure.

Radiographic measurement of crestal bone loss changes.

Close modal

Data management and statistical analysis

A database was created using Excel 2007 (Microsoft Inc, Seattle, Wash) with appropriate checks to identify errors. Descriptive statistics were computed for all study variables. Univariate and multivariate regression mixed-effects models, if indicated, were developed to evaluate possible associations between the predictor variables and crestal bone level changes. For the secondary outcome measure, Cox proportional hazards modeling was used to identify patients at risk for excessive crestal bone loss with bone loss >1.5 mm within a year after implant placement. A commercially available statistical software package (SAS v.9.3, 2002–2010, SAS, Cary, NC) was used for analyses. When assessing the univariate models, candidate variables with P values ≤.15 were considered. These eligible candidate variables were then further considered when evaluating the multivariate model. The statistical level of significance, P values ≤.05, were considered statistically significant when multivariate models were assessed.

Over the study period, 85 patients received 184 implants (see Table 1 for a summary of the sample's descriptive statistics). The sample was composed of 43 (50.6%) men with a mean age of 55 ± 12.3 years.

Table 1

Descriptive statistics of patient-specific and implant-specific variables

Descriptive statistics of patient-specific and implant-specific variables
Descriptive statistics of patient-specific and implant-specific variables

A total of 23 implants (15.5%) were placed in 11 (12.9%) smokers. Most patients were ASA class I (82 patients, 96.5%; 141 implants, 95.3%). In addition, 7 implants (4.7%) were placed in 3 (3.5%) patients with a diagnosis of diabetes, prior chemotherapy or radiation therapy, or liver disease.

A total of 57 implants (38.5%) were placed in the lower jaw, and 49 implants (33.1%) were placed anteriorly in both jaws. A total of 148 implants were evaluated and noted as placed adjacent to either tooth, implant, or both; 30.4% of the implants were placed in between 2 natural teeth.

Implant diameters varied from 3.25–6.0 mm, with associated lengths of 8.0–18.0 mm. The mean diameter and lengths were 4.4 ± 0.7 mm and 12.2 ± 1.6 mm, respectively. A total of 66 implants (44.6%) were coated and 49 implants (33.1%) were immediately loaded; 99 (66.9%) were loaded in delayed fashion. Among those immediately placed, 35 (23.7%) were placed following the extraction of a tooth and 2 (1.4%) were placed following the removal of an implant. The remaining implants (111; 75%) were placed in delayed fashion. Exactly 103 (69.6%) implants were placed using a 2-stage protocol; 45 (31.4%) were placed in 1 stage with placement of a healing or restorative abutment on the same day.

The DRPs such as an internal or external sinus lift, ridge split, onlay, or inlay graft were performed on 62 (41.9%) implants. Immediate DRPs were performed at the time of implant placement in 43 (69.4%) implant sites. The bone graft materials used were autogenous (9; 14.5%), allogenic (demineralized bone powder; 40; 64.5%), and alloplastic (7; 11.3%). Six (9.7%) implant sites received a combination of bone graft types, and 28 (18.9%) bone graft sites were reinforced with a resorbable membrane.

Implant restorations included single-unit crown (69; 48.9%), fixed bridge (52; 36.9%), fixed denture/hybrid (10; 7.1%), and overdenture or removable prosthesis (10; 7.1%). One implant was incorporated in a prosthesis with 2 natural teeth. The total number of implants used in the prosthesis varied from 1 to 6 implants; the number of teeth not supported by the implants in the prosthesis ranged from 0 to 12.

The median duration for follow-up was 0.7 years (range, 0.04–5.64 years). The mean change of the crestal bone was −2.1 ± 1.5 mm (range = −12.5–0.5 mm with median −1.77; Table 1). In the univariate model, 2 variables, ASA and immediate implant placement, were near statistically associated with crestal bone loss (Table 2). None of the variables were statistically significant with regard to bone loss in the multiple regression models (Table 3).

Table 2

Univariate mixed regression analysis of variable associated with worst crestal bone changes

Univariate mixed regression analysis of variable associated with worst crestal bone changes
Univariate mixed regression analysis of variable associated with worst crestal bone changes
Table 3

Multivariate mixed regression analysis of variable associated with worst crestal bone changes

Multivariate mixed regression analysis of variable associated with worst crestal bone changes
Multivariate mixed regression analysis of variable associated with worst crestal bone changes

A total of 84 implants (66.1 %) had >1.5 mm of bone loss within 1 year (Table 1). In the univariate model (Table 4), 2 variables, smoker and anterior/posterior location, were near statistically significant with regard to bone loss categorized as a binary variable. However, none of the variables were statistically significant in multivariate Cox hazards analysis (Table 5).

Table 4

Univariate Cox hazards analysis of variable associated with crest bone loss >1.5 mm within 1 year after the implant placement

Univariate Cox hazards analysis of variable associated with crest bone loss >1.5 mm within 1 year after the implant placement
Univariate Cox hazards analysis of variable associated with crest bone loss >1.5 mm within 1 year after the implant placement
Table 5

Multivariate Cox hazards analysis of variable associated with crest bone loss >1.5 mm within 1 year after the implant placement

Multivariate Cox hazards analysis of variable associated with crest bone loss >1.5 mm within 1 year after the implant placement
Multivariate Cox hazards analysis of variable associated with crest bone loss >1.5 mm within 1 year after the implant placement

The purpose of this study was to estimate the magnitude of crestal bone loss and to identify factors associated with changes in crestal bone height following placement of dental implants. The investigators hypothesized that there was a set of 1 or more variables associated with increased levels of bone loss that may be manipulated by the clinician to enhance outcomes or may help to identify patients at risk for excessive crestal bone loss. In brief, changes in crestal bone height during the study interval (from 15 to 2057 days) had a mean loss of 2.1 ± 1.5 mm and 66.1% of implants had >1.5 mm of bone loss at 1 year. The results of this study failed to confirm the proposed hypothesis. The investigators did not identify any variables associated with crestal bone loss that may be modified by the clinician to preserve crestal bone.

The change in crestal bone height after the implant placement was quantified using radiographic measurements, which were corrected by the magnified factors. The margin of error and limitation still exist in evaluating linear bone changes in nonidentical radiographs using reference dimensions of the implants.10  However, the precision and the validity of the measurement on noninvasive radiographic images were adequate when compared with the histometric anaylsis.11  The predictor variables were individually discussed and compared with previous studies.

Surface design

The aim to discover the modifiable predictor factors to improve dental implant success rates have been extensively studied in the literature. The types of implant design and surface are known to influence the crestal bone changes. Valderrama et al8  demonstrated the histological evaluation of crestal bone gain with the use of chemically modified, sandblasted, acid-etched (SLA) surfaced implants without a machined collar on animal models after 3 and 12 months under loading conditions in the canine mandible. Also, high-implant success rates on irradiated oral squamous cell carcinoma patients was shown with chemically modified implants (n = 28) and conventional SLA titanium surface implants (n = 27), 100% and 96%, respectively.12  The implant with a longer machined collar length showed no significant difference in bone loss, and the shorter collar was recommended for the area with esthetic concerns.13  The randomized controlled study from Shin et al14  demonstrated significantly decreased crestal bone loss (P < .05) with rough surfaced microthreads at the implant neck compared with the machine-surfaced group.

Ideally, subcrestally placed implants would show optimal osseointegration and have a greater success rate; however, subcrestally placed implants, especially smooth-collared implants, showed greater crestal bone changes.6  In contrast, the radiographic study by Hermann et al15  showed rapid bone remodeling during the early healing phase after implant placement for nonsubmerged implants and after abutment connection for submerged implants.

Loading

Implant placement is followed by prosthesis placement as a final restorative step either in immediate or delayed fashion. The restorations consist of single-unit or multi-unit crowns, or dentures. The benefit of immediate loading at the time of implant placement is still controversial. The crestal bone changes were not significantly different with regard to implant stability on immediate loading of 2 implants supporting a magnet attachment retained overdenture.9  However, Susarla et al16  stated that the immediately loaded implant is 2.7 times more likely to fail at 1 year compared with delay-loaded implants. In contrast, the crestal bone level changes with immediately loaded implants were within the recommended range for 92.5% of the evaluated implants.7  The preliminary study by Brochu et al17  indicated that early loading did not show an influence on crest bone height or stability during a 4-month follow-up period. The histologic evaluation of the animal model also demonstrated that the loading is not a relevant factor in peri-implant bone resorption for 1-year function.18  The progressive loading concept on a conventional staged implant placement was evaluated using digital imaging analysis and digital subtraction to determine the effectiveness on preserving crestal bone height and peri-implant bone density. Imaging on the conventional staged implants resulted in less bone loss and increased peri-implant density in the progressive loading group.19  Also, the length of cantilever extension on implant-supporting cantilevered bar–retained dentures showed no influence on crestal bone changes.20 

Immediate implant

Immediate implant placement, after extraction, significantly reduces overall treatment time for patients; therefore, it is preferred by many surgeons when indicated. However, immediate implant placement, especially with xenograft bone graft, showed an increase in bone loss on buccal aspects with low osseointegration.21  Block et al22  compared hard- and soft-tissue response to immediate and delayed placement of an implant in the maxillary anterior region with immediate provisionalization. This study concluded that the hard-tissue change was similar in the 2 groups; however, 1 mm more facial gingival margin was preserved on immediate implant with provisionalization.22  Immediate implant placement with provisionalization seems to preserve soft tissue with possible negative effects on bone loss.21,22  However, some argue that the crestal bone loss after immediate implant placement with or without bone grafting is clinically acceptable.2325  Therefore, evaluation for the appropriateness of immediate implant placement should be individually assessed to provide the best outcome.

Staging

The 2-stage surgical approach for dental implant placement appeared to minimize the amount of crestal bone loss. Toljanic et al26  demonstrated that early soft-tissue exposure of the implant between stage I and stage II surgery is 3.9 times more likely to result in bone loss. These differences may be the result of plaque accumulation and inflammation at the early perforation and partial exposure of the implant.27  The rate of bone loss after implant placement is greater during the initial healing phase, after which the rate slows down.2830  A direct relationship exists between spontaneously early, cover-screw perforation and early crestal bone loss.31  Linkevicius et al32  compared the thickness of the soft tissue on the crestal bone around the dental implant and stated that if the tissue thickness is 2.0 mm or less, crestal bone loss up to 1.45 mm may occur. These studies suggest that thicker gingival tissue on crestal bone has lesser bone changes and stress the importance of good closure of the gingival flap to minimize the increase in bone loss due to early implant exposure to the oral cavity.

In contrast, the 10-year prospective study by Kim et al29  evaluated crestal bone loss on 1-stage dental implants and showed clinically acceptable bone loss. Also, the 8-year follow-up on the 1-stage surgical approach for screw-retained full-arch prostheses in maxilla showed minimal crestal bone loss of 0.3 ± 0.72 mm.33  Our study did not show statistical significance of staging implants correlating to crestal bone change; however, it would be prudent to avoid 1-stage implant placement on an area with inadequate or marginal alveolar bone where even minimal bone loss can be detrimental to implant survival.

Dentoalveolar reconstructive procedures

Bone grafting is used during the dental extraction and socket preservation method for future implant placement. Bone grafting is also readily used concurrently with implant placement with barrier membranes to enhance the deficient implant recipient site. The need for bone grafting at the implant site suggests a lack of adequate alveolar bone around the implant site. Therefore, the dentoalveolar reconstructive procedure indicates a less than optimal implant environment. The types of reconstructive procedures available include a broad spectrum from simple bone grafting, to onlay, sinus lifting, or ridge splitting. Bone-grafting materials are autologous, allograft, xenograft, or synthetic. There are pros and cons of each with different chemical and physiological properties such as osteogenesis, osteoinduction, or osteoconduction capabilities. Not all bone grafting is successful and may result in a high percentage of clinically significant resorption. This is likely due to predisposed less-optimal bone for the implant in combination with resorption of the grafting materials. However, the retrospective cohort study by Woo et al34  suggested that the use of DRP was not an independent factor for implant failure.

Studies21,35  show significant buccal bone loss after a xenografting procedure and fail to demonstrate the positive effects of xenograft on osseous wound defect between the bone crest and the coronal aspect of the implants. Koutouzis and Lundgren24  demonstrated the comparable crestal bone changes on 12-month follow-up between implants placed in an allograft reconstructed socket v. native bone, with a mean marginal bone loss of 0.15 mm for both groups. Local bone graft procedures can provide an adequate amount of bone for an implant placement; however, the resorption pattern, especially in the anterior, is unpredictable with individual variation.36  The maxillary sinus augmentation precedes the implant placement on loss of vertical height in the posterior maxilla to accommodate the bulk of the bone for the implant. Unlike the risk factor of tobacco use, immediate implant, and implant staging, the maxillary sinus augmentation procedure showed no association with increased risk factor for implant failure.1,35,34  Other risk factors for implant failure included implant length and proximity of an adjacent implant.3  The amount of bone remodeling and resorption after the bone graft procedure is unpredictable; however, early detection and treatment of early progressive bone loss around the dental implants showed an improved implant failure rate.37 

The limitation of the study includes the use of data from a single surgical center with limited long-term follow-up on many patients. In an attempt to minimize the radiographic measurement error and to ensure reliability, the same person performed the measurement. To detect an association between the dependent variable and the independent variable on univariate analysis, we would need a total of 800 implants for a detection power of 80% at a 2-sided 5% significance level if the true change in the dependent variable is 0.1-mm bone-level change per 1-unit change in the independent variable.

Examination of these variables in an appropriately powered prospective study might find that some of these variables have a negative impact on the long-term stability of crestal bone. Further study of a large sample size would determine the effects of predictor variables, which can be modified by patients and surgeons to improve the amount of crestal bone change and overall implant survival as well as to identify patients at risk for increased bone loss.

In this study, the mean bone loss following implant placement was 2.1 mm, and 66.1% of the implants had >1.5 mm of bone loss in the first year. None of the variables included in analyses were statistically significant with regard to an increased risk for crestal bone loss or excessive bone loss within the first year after implant placement.

Abbreviations

ASA

American Society of Anesthesiology Classification

DRP

dentoalveolar reconstructive procedure

SLA

sandblasted, acid etched

The authors wound like to acknowledge Massachusetts General Hospital, Department of Oral and Maxillofacial Surgery's Education and Research Fund (S.Y.K., D.T.D.) and Center for Applied Clinical Investigation (T.B.D., S.-K.C.), as well as the Massachusetts General Hospital Physicians Organization (S.-K.C., T.B.D.). The authors would also like to thank Adirondack Oral and Maxillofacial Surgery, its clinicians, and staff for allowing access to their patient sample. This project was supported in part by a grant to the Center for Applied Clinical Investigation by Adirondack Oral & Maxillofacial Surgery (Albany, NY).

1.
McDermott
NE
,
Chuang
SK
,
Woo
VV
,
Dodson
TB.
Maxillary sinus augmentation as a risk factor for implant failure
.
Int J Oral Maxillofac Implants
.
2006
;
21
:
366
374
.
2.
Chuang
SK
,
Cai
T
,
Douglass
CW
,
Wei
LJ
,
Dodson
TB.
Frailty approach for the analysis of clustered failure time observations in dental research
.
J Dent Res
.
2005
;
84
:
54
58
.
3.
McDermott
NE
,
Chuang
SK
,
Woo
VV
,
Dodson
TB.
Complications of dental implants: identification, frequency, and associated risk factors
.
Int J Oral Maxillofac Implants
.
2003
;
18
:
848
855
.
4.
Vehemente
VA
,
Chuang
SK
,
Daher
S
,
Muftu
A
,
Dodson
TB.
Risk factors affecting dental implant survival
.
J Oral Implantol
.
2002
;
28
:
74
81
.
5.
Chuang
SK
,
Wei
LJ
,
Douglass
CW
,
Dodson
TB.
Risk factors for dental implant failure: a strategy for the analysis of clustered failure-time observations
.
J Dent Res
.
2002
;
81
:
572
577
.
6.
Stein
AE
,
McGlmphy
EA
,
Johnston
WM
,
Larsen
PE.
Effects of implant design and surface roughness on crestal bone and soft tissue levels in the esthetic zone
.
Int J Oral Maxillofac Implants
.
2009
;
24
:
910
919
.
7.
Yoo
RH
,
Chuang
SK
,
Erakat
MS
,
Weed
M
,
Dodson
TB.
Changes in crestal bone levels for immediately loaded implants
.
Int J Oral Maxillofac Implants
.
2006
;
21
:
253
261
.
8.
Valderrama
P
,
Bornstein
MM
,
Jones
AA
,
Wilson
TG
,
Higginbottom
F
,
Cochran
DL.
Effects of implant design on marginal bone changes around early loaded chemically-modified sand blasted, acid etched surfaced implants: a histological analysis in dogs
.
J Periodontol
.
2011
;
82
:
1025
1034
.
9.
Pae
A
,
Kim
JW
,
Kwon
KR.
Immediate loading of two implants supporting a magnet attachment-retained overdenture: one-year clinical study
.
Implant Dent
.
2010
;
19
:
428
436
.
10.
Brägger
U
,
Häfeli
U
,
Huber
B
,
Hämmerle
CH
,
Lang
NP.
Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants
.
Clin Oral Implants Res
.
1998
;
9
:
218
224
.
11.
Hermann
JS
,
Schoolfield
JD
,
Nummikoski
PV
,
Buser
D
,
Schenk
RK
,
Cochran
DL.
Crestal bone changes around titanium implants: a methodologic study comparing linear radiographic with histometric measurements
.
Int J Oral Maxillofac Implants
.
2001
;
16
:
475
485
.
12.
Heberer
S
,
Kilic
S
,
Hossamo
J
,
Raguse
JD
,
Nelson
K.
Rehabilitation of irradiated patients with modified and conventional sandblasted acid-etched implants: preliminary results of a split-mouth study
.
Clin Oral Implants Res
.
2011
;
22
:
546
551
.
13.
Hänggi
MP
,
Hänggi
DC
,
Schoolfield
JD
,
Meyer
J
,
Cochran
DL
,
Hermann
JS.
Crestal bone changes around titanium implants. Part I: a retrospective radiographic evaluation in humans comparing two non-submerged implant designs with different machined collar lengths
.
J Periodontol
.
2005
;
76
:
791
802
.
14.
Shin
YK
,
Han
CH
,
Heo
SJ
,
Kim
S
,
Chun
HJ.
Radiographic evaluation of marginal bone level around implants with different neck designs after 1 year
.
Int J Oral Maxillofac Implants
.
2006
;
21
:
789
794
.
15.
Hermann
JS
,
Cochran
DL
,
Nummikoski
PV
,
Buser
D.
Crestal bone changes around titanium implants: a radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible
.
J Periodontol
.
1997
;
68
:
1117
1130
.
16.
Susarla
SM
,
Chuang
SK
,
Dodson
TB.
Delayed versus immediate loading of implants: survival analysis and risk factors for dental implant failure
.
J Oral Maxillofac Surg
.
2008
;
66
:
251
255
.
17.
Brochu
JF
,
Anderson
JD
,
Zarb
GA.
The influence of early loading on bony crest height and stability: a pilot study
.
Int J Prosthodont
.
2005
;
18
:
506
512
.
18.
Assenza
B
,
Scarano
A
,
Petrone
G
,
Iezzi
G
,
Thams
U
,
San Roman F, Piattelli A. Crestal bone remodeling in loaded and unloaded implants and the microgap: a histologic study
.
Implant Dent
.
2003
;
12
:
235
241
.
19.
Appleton
RS
,
Nummikoski
PV
,
Pigno
MA
,
Cronin
RJ
,
Chung
KH.
A radiographic assessment of progressive loading on bone around single osseointegrated implants in the posterior maxilla
.
Clin Oral Implants Res
.
2005
;
16
:
161
167
.
20.
Semper
W
,
Heberer
S
,
Nelson
K.
Retrospective analysis of bar-retained dentures with cantilever extension: marginal bone level changes around dental implants over time
.
Int J Oral Maxillofac Implants
.
2010
;
25
:
385
393
.
21.
Hsu
KM
,
Choi
BH
,
Ko
CY
,
Kim
HS
,
Xuan
F
,
Jeong
SM.
Ridge alterations following immediate implant placement and the treatment of bone defects with Bio-Oss in an animal model
.
Clin Implant Dent Relat Res
.
2012
;
14
:
690
695
.
22.
Block
MS
,
Mercante
DE
,
Lirette
D
,
Mohamed
W
,
Ryser
M
,
Castellon
P.
Prospective evaluation of immediate and delayed provisional single tooth restorations
.
J Oral Maxillofac Surg
.
2009
;
67
(
11 suppl
):
89
107
.
23.
Huber
S
,
Rentsch-Kollàr
A
,
Grogg
F
,
Katsoulis
J
,
Mericske
R. A
1-year controlled clinical trial of immediate implants placed in fresh extraction sockets: stability measurements and crestal bone level changes
.
Clin Implant Dent Relat Res
.
2012
;
14
:
491
500
.
24.
Koutouzis
T
,
Lundgren
T.
Crestal bone-level changes around implants placed in post-extraction sockets augmented with demineralized freeze-dried bone allograft: a retrospective radiographic study
.
J Periodontol
.
2010
;
81
:
1441
1448
.
25.
Covani
U
,
Cornelini
R
,
Barone
A.
Vertical crestal bone changes around implants placed into fresh extraction sockets
.
J Periodontol
.
2007
;
78
:
810
815
.
26.
Toljanic
JA
,
Banakis
ML
,
Willes
LA
,
Graham
L.
Soft tissue exposure of endosseous implants between stage I and stage II surgery as a potential indicator of early crestal bone loss
.
Int J Oral Maxillofac Implants
.
1999
;
14
:
436
441
.
27.
Tal
H.
Spontaneous early exposure of submerged implants: I. Classification and clinical observations
.
J Periodontol
.
1999
;
70
:
213
219
.
28.
Cochran
DL
,
Nummikoski
PV
,
Schoolfield
JD
,
Jones
AA
,
Oates
TW.
A prospective multicenter 5-year radiographic evaluation of crestal bone levels over time in 596 dental implants placed in 192 patients
.
J Periodontol
.
2009
;
80
:
725
733
.
29.
Kim
DM
,
Badovinac
RL
,
Lorenz
RL
,
Fiorellini
JP
,
Weber
HP. A
10-year prospective clinical and radiographic study of one-stage dental implants
.
Clin Oral Implants Res
.
2008
;
19
:
254
258
.
30.
Albrektsson
T
,
Zarb
G
,
Worthington
P
,
Eriksson
AR.
The long-term efficacy of currently used dental implants: a review and proposed criteria of success
.
Int J Oral Maxillofac Implants
.
1986
;
1
:
11
25
.
31.
Cehreli
MC
,
Kökat
AM
,
Uysal
S
,
Akca
K.
Spontaneous early exposure and marginal bone loss around conventionally and early-placed submerged implants: a double-blind study
.
Clin Oral Implants Res
.
2010
;
21
:
1327
1333
.
32.
Linkevicius
T
,
Apse
P
,
Grybauskas
S
,
Puisys
A.
The influence of soft tissue thickness on crestal bone changes around implants: a 1-year prospective controlled clinical trial
.
Int J Oral Maxillofac Implants
.
2009
;
24
:
712
719
.
33.
Mertens
C
,
Steveling
HG.
Implant-supported fixed prostheses in the edentulous maxilla: 8-year prospective results
.
Clin Oral Implants Res
.
2011
;
22
:
464
472
.
34.
Woo
VV
,
Chuang
SK
,
Daher
S
,
Muftu
A
,
Dodson
TB.
Dentoalveolar reconstructive procedures as a risk factor for implant failure
.
J Oral Maxillofac Surg
.
2004
;
62
:
773
780
.
35.
Koutouzis
T
,
Fetner
M
,
Fetner
A
,
Lundgren
T.
Retrospective evaluation of crestal bone changes around implants with reduced abutment diameter placed non-submerged and at subcrestal positions: the effect of bone grafting at implant placement
.
J Periodontol
.
2011
;
82
:
234
242
.
36.
Jemt
T
,
Lekholm
U.
Single implants and buccal bone grafts in the anterior maxilla: measurements of buccal crestal contours in a 6-year prospective clinical study
.
Clin Implant Dent Relat Res
.
2005
;
7
:
127
135
.
37.
Alghamdi
AS.
Successful treatment of early implant failure: a case series
.
Clin Implant Dent Relat Res
.
2012
;
14
:
380
387
.