The purpose of this study is to use cone-beam computerized tomography (CBCT) scans with oblique-transverse reconstruction modality to measure and compare the anterior loop length (AnLL) of the mental nerve between gender and age groups and to compare the difference between the right and left sides. Sixty-one female and 61 male CBCT scans were randomly selected for each age group: 21–40, 41–60, and 61–80 years. Both right- and left-side AnLLs were measured in each subject using i-CATVision software to measure AnLLs on the oblique transverse plane using multiplanar reconstruction. The anterior loop was identified in 85.2% of cases, with the mean AnLL of the 366 subjects (732 hemimandibles) being 1.46 ± 1.25 mm with no statistically significant difference between right and left sides or between different gender groups. However, the mean AnLL in the 21–40 year group (1.89 ± 1.35 mm) was larger than the AnLL in the 41–60 year group (1.35 ± 1.19 mm) and the 61–80 year group (1.13 ± 1.08 mm). In conclusion, when placing implants in close proximity to mental foramina, caution is recommended to avoid injury to the inferior alveolar nerve. No fixed distance anteriorly from the mental foramen should be considered safe. Using CBCT scans with the oblique-transverse method to accurately identify and measure the AnLL is of utmost importance in avoiding and protecting its integrity.

Surgery in the anterior mandible such as implant placement in the interforaminal area or chin grafting may damage the anterior loop of the mental nerve, resulting in neurosensory disturbances. During surgery, surgeons usually expose the mental foramen to visualize the position of the mental nerve. However, without knowing the anterior loop length, surgeons have a high risk of violating the anterior loop, when present.

Preoperative radiographic examination aids in developing a comprehensive treatment plan for patients who need dental implant surgery. It helps determine the proper size, location, and angulation for each dental implant as well as the number of implants to be placed.1,2  Some authors claim that 2-dimensional (2D) radiographs are sufficient for presurgical implant planning3 ; however, others believe there is a need for additional cross-sectional imaging.46  Recently, it has been recommended that cross-sectional imaging be used for the assessment of all dental implant sites and that cone-beam computerized tomography (CT) is the imaging method of choice for gaining this information.4 

When planning to place implants in the mandible, one of the most important anatomic landmarks is the mandibular canal, in which the inferior alveolar nerve passes through and continues anteriorly as the mental nerve, exiting at the mental foramen. The mental nerve may have an anterior loop, which is described in Sicher's Oral Anatomy.7  The anterior loop is described as “the mental canal which rises from the mandibular canal and runs outward, upward and backward to open at the mental foramen.” The location of the most distal implants in the interforaminal area when planning an implant-supported fixed complete denture is determined by the position of the mental foramen and the anterior loop of the mental neurovascular bundle.810  To place the implant closest to the mental foramen with concern on the anterior loop is the key factor for increasing the A-P spread and reducing distal cantilever.11,12  However, complications of surgical trauma to the mental nerve can result in neurosensory disturbances and altered sensation of the lower lip and chin after implant placement.13 

Clinically, the anterior loop cannot be seen but can be detected in panoramic radiographs, cone beam computerized tomography (CBCT), spiral CT, and magnetic resonance imaging. However, in the study by Arzouman et al,14  the authors concluded that significantly fewer loops were detected in panoramic radiographs as compared with anatomic assessment. Also, significantly shorter anterior loops were identified in panoramic radiographs than when direct measurements were made. Moreover, Kuzmanovic et al10  showed that 50% of the radiographically observed anterior loops of the mental canal were misinterpreted by observers with panoramic radiography, and 62% of the anatomically identified loops were not observed radiographically. They concluded that panoramic radiographs are unreliable and have high incidences of false-positives and false-negatives in identifying the anterior loop.

Spiral CT and CBCT have also been used for measuring anterior loops in the literature and tend to be more reliable. Kaya et al15  showed spiral CT scans demonstrated a higher prevalence of mental loops than panoramic radiographs. Uchida et al16  compared the CBCT and anatomic measurements and concluded that the average length of the anterior loop was 2.2 ± 0.8 mm using CBCT, and no significant differences were found between CBCT and anatomic measurements.

Ngeow et al17  investigated the visualization of the anterior loop in “different age-groups and genders” using panoramic radiographs, but this study did not facilitate CBCT scans. Different methods of measuring the anterior loop length (AnLL) on CBCT scans were described in the literature. In one study, a software program was used to draw tracing lines of the mental nerve to measure the length of the loop.18  Some studies measured by counting the first and last cross-sectional 0.5-mm-thick slices after identifying the anterior loop and mental foramen. However, Kaya et al15  stated that assessing a tomographic cross-sectional cut for the location of the mandibular or mental canals was difficult. In the present study, we presented a simpler method using i-CATVision software to locate the mental foramen and anterior loop on a single oblique transverse view and measure the length of the anterior loop.

The objective of this study is to measure and compare the AnLL of the mental nerve between gender and age groups and to compare the difference between the right and left sides using CBCT. The null hypothesis is that according to the analysis of CBCT scans, age, gender, and right versus left sides have no influence on the anterior loop length.

To estimate the proper sample size for evaluating the difference between groups, StatSoft STATISTICA (power analysis software) with an α of .05 and 2-tailed t test of significance was used. An estimation was made that 176 participants in each gender group and a total of 352 participants would provide 80% power for detecting a small-to-medium effect size (r = .3) in the relationship between AnLL and gender. After setting α = .05, root mean square standardized effect = 0.2, the 1-way analysis of variance (ANOVA) test of significance was used to make a prior estimate that 122 participants in each age group (3 groups) and a total of 366 participants would provide 80% power in the relationship between AnLL and age groups. Combining the results above, 61 women and 61 men in each age group, with a total of 366 participants, were used in the study.

Sixty-one female and 61 male patients were randomly selected for each age group (21–40, 41–60, and 61–80 years) from existing Loma Linda University CBCT scans. All CBCT scans were taken by I-CAT Cone-Beam 3D Dental Imaging System Model (Imaging Sciences International, Hatfield, Penn) under 6- or 13-cm field of view, 20 seconds scan time, and 0.4-mm voxel size. Both right- and left-side AnLLs were measured in each subject. I-CATVision software (Croall Radiography Inc, version 1.8.1.10) was used to measure the AnLL by using multiplanar reconstruction. Multiplanar reconstruction allows images to be created from the original axial plane in either the coronal, sagittal, or oblique plane.

First, the axial cut in the sagittal plane was adjusted to identify the best view of the mental foramen in the axial plane (Figure 1).

Figure 1.

How to move the axial cut (red bar) in the sagittal plane until the best view of mental foramen (yellow circle) is attained in the axial plane.

Figure 1.

How to move the axial cut (red bar) in the sagittal plane until the best view of mental foramen (yellow circle) is attained in the axial plane.

Close modal

Second, the axial plane was rotated until the sagittal cut was parallel to the buccal plate in the area of the mental foramen. Meanwhile, the coronal cut in the axial plane was adjusted to identify the best view of the mental foramen in the coronal plane (Figure 2).

Figure 2.

Axial plane that is rotated until the sagittal cut (green bar) is parallel to the buccal plate in the area of the mental foramen, and the coronal cut (blue bar) in the axial plane that is adjusted until the best view of the mental foramen (yellow square) is attained in the coronal plane.

Figure 2.

Axial plane that is rotated until the sagittal cut (green bar) is parallel to the buccal plate in the area of the mental foramen, and the coronal cut (blue bar) in the axial plane that is adjusted until the best view of the mental foramen (yellow square) is attained in the coronal plane.

Close modal

Third, the coronal plane was enlarged, and an oblique cut that passed through the center of the mental foramen was made to create an oblique plane, which allowed visualization of the mental foramen and anterior loop at the same time (Figures 3 and 4). Fourth, this view was enlarged so that measurements could be made to the nearest 0.4 mm (Figure 4). Fifth, a line (line 1) was drawn parallel to the buccal plate, and another line (line 2) was made perpendicular to line 1, which passed through the most anterior point of the anterior loop. (It could be the origin of the incisive canal or the most anterior point of the mental loop curvature.) AnLL was measured from the most anterior point of the mental foramen to line 2 (Figure 4). When the anterior loop was not present or the origin of the incisive canal was located posterior to the mental foramen, negative values were recorded.

Figures 3–6.

Figure 3. How to make an oblique cut using the function “line” to gain an ideal oblique view (Figure 4). (The cut is adjusted to pass through the center of the mental foramen in the coronal plane and meanwhile to obtain the best view of the anterior loop in the oblique plane.). Figure 4. Mental foramen, anterior loop of the mental nerve, and bifurcation at the same view. Line 1 is parallel to the buccal plate. Line 2 is perpendicular to line 1 and passes through the most anterior point of the anterior loop. (In this case, it is the part of the mental nerve, not the origin of the incisive canal.) Line 3 (yellow) shows the measurement of the anterior loop length. Figure 5. Example of the measurement (line 3: 6.8 mm) of the maximal anterior loop length. The average of all measurements (6.8, 6.8, 6, 6.4, 6.8, 7.2 mm) was 6.67 mm. Figure 6. Example of the measurement (line 3: −3.2 mm) of the minimal anterior loop length. The average of all measurements (−3.2, −3.2, −3.2, −2.8, −2.4, −2.4 mm) was −2.87 mm.

Figures 3–6.

Figure 3. How to make an oblique cut using the function “line” to gain an ideal oblique view (Figure 4). (The cut is adjusted to pass through the center of the mental foramen in the coronal plane and meanwhile to obtain the best view of the anterior loop in the oblique plane.). Figure 4. Mental foramen, anterior loop of the mental nerve, and bifurcation at the same view. Line 1 is parallel to the buccal plate. Line 2 is perpendicular to line 1 and passes through the most anterior point of the anterior loop. (In this case, it is the part of the mental nerve, not the origin of the incisive canal.) Line 3 (yellow) shows the measurement of the anterior loop length. Figure 5. Example of the measurement (line 3: 6.8 mm) of the maximal anterior loop length. The average of all measurements (6.8, 6.8, 6, 6.4, 6.8, 7.2 mm) was 6.67 mm. Figure 6. Example of the measurement (line 3: −3.2 mm) of the minimal anterior loop length. The average of all measurements (−3.2, −3.2, −3.2, −2.8, −2.4, −2.4 mm) was −2.87 mm.

Close modal

Statistical analysis

Two examiners were involved in the study. Each examiner measured AnLL on both sides of the patient 3 different times. Intra- and Interexaminer reliability were tested by using SPSS intraclass correlation coefficient (Cronbach's alpha value >.8 means optimal agreement, >.9 means excellent agreement). The prevalence of the anterior loop (when AnLL > 0 mm) was calculated. After calculating the mean and standard deviation, the independent t test was used to compare AnLL between gender groups. A paired t test was used to compare AnLL between the right and left sides. One-way ANOVA was used to compare AnLL among the 3 age groups. The α level of all the statistic tests was set as .05.

All measurements were collected for intra- and interexaminer reliability tests. A Cronbach's alpha value of .954 and .976 was obtained in the first and second examiner, showing an excellent agreement. An intraclass correlation coefficient of .904 was obtained comparing 2 examiners, showing excellent agreements as well.

The measurements of the AnLL comparing the right and left side in different gender and age groups are listed in Tables 14. The anterior loop was present (length >0 mm) in 624 of 732 hemimandibles (prevalence = 85.2%). The AnLL of the 366 subjects (732 hemimandibles) was 1.46 ± 1.25 mm. The maximal and minimal AnLL were 6.67 mm and −2.87 mm (Figures 5 and 6). The mean AnLL on the right side was 1.47 ± 1.39 mm and on the left side was 1.44 ± 1.39 mm. There was no statistical significance between groups. The mean AnLL was 1.51 ± 1.24 mm for men and 1.40 ± 1.26 mm for women, and no statistically significant differences were found.

Table 1

Prevalence and measurements of the anterior loop length of the mental nerve comparing the right and left sides

Prevalence and measurements of the anterior loop length of the mental nerve comparing the right and left sides
Prevalence and measurements of the anterior loop length of the mental nerve comparing the right and left sides
Table 2

Prevalence and measurements of the anterior loop length of the mental nerve comparing different genders

Prevalence and measurements of the anterior loop length of the mental nerve comparing different genders
Prevalence and measurements of the anterior loop length of the mental nerve comparing different genders
Table 3

Prevalence and measurements of the anterior loop length of the mental nerve comparing different age groups

Prevalence and measurements of the anterior loop length of the mental nerve comparing different age groups
Prevalence and measurements of the anterior loop length of the mental nerve comparing different age groups
Table 4

Post hoc statistical analysis comparing different age groups

Post hoc statistical analysis comparing different age groups
Post hoc statistical analysis comparing different age groups

Among the age groups, 1-way ANOVA statistical analysis showed a significant difference between groups (P = .000). Both post hoc tests, Bonferroni and Scheffé test, showed the AnLL of the 21–40 year group was significantly different from groups 41–60 and 61–80 years. The mean AnLL in the 21–40 year group (1.89 ± 1.35 mm) was larger than the AnLL in the 41–60 year group (1.35 ± 1.19 mm) and 61–80 year group (1.13 ± 1.08 mm).

In the literature, the average measurements of the AnLL varied. The mean AnLL varied from 0.1 mm19 to 6.92 mm.20  The reason that the results varied might be due to different diagnostic tools (cadavers, dry skulls, 2D radiographs, and 3D radiographs) different population, (different age, gender, race, dental status), different methods of measuring (direct measurements using probe, calipers), or different methods of interpreting the radiographs. In our study, the mean AnLL of the 366 subjects on CBCT scans (732 hemimandibles) was 1.46 ± 1.25 mm. This corresponded with most of the cadaver studies that used direct measurements. Solar et al21  found that the mean AnLL was 1 mm and ranged from 0.5 to 5 mm, Kuzmanovic et al10  found the mean AnLL was 1.2 mm, and Uchida et al22  found it was 1.5 mm. All of these were cadaver studies.

Studies by Arzouman et al,14  Kaya et al,15  and Misch and Crawford23  found mean AnLLs of 3.45 mm, 3.75 mm, and 5 mm, respectively. A possible reason for these average AnLLs compared with those of the current study could be the fact that the previous investigators used 2D radiographs as the measuring tools. Kuzmanovic et al10  concluded that panoramic radiographs are unreliable and have high incidences of false-positives and false-negatives in identifying the anterior loop. They found that radiographic length of the anterior loop of the mental canal can be measured only in radiographs in which the entire course of the mental canal is visualized, from the mandibular canal through the mental foramen (type I, or continuous type; Yosue and Brooks classification24). We applied this concept on the 3D CBCT scans. We think that the most accurate way to measure the anterior loop is when the mandibular canal, the anterior loop, the incisive canal, and the mental foramen can be continuously visualized in the same view.

Cone beam computed tomography was introduced in the early 2000s with its great decrease in dose compared with the conventional CT.2527  Poeschl et al28  found that CBCT was as accurate as conventional multislice CT with regard to its use in image-guided implant surgery. Al-Ekrish and Ekram29  stated that the mean of the CBCT absolute errors was even smaller than that of the multi-detector CT absolute errors for the overall data, as well as for the site-specific data. Moreover, Santana et al30  and Uchida et al16  stated there was no statistically significant difference on the AnLL between anatomic measurements from cadavers and measurements obtained from CBCT images. Although CBCT had been proven to be accurate, studies using CBCT to analyze the average length of the anterior loop still showed contrasting results from 0.89 mm31 to 6.92 mm.20  We found that the methods of measuring the AnLL on CBCT were different. Rosa et al32  determined the mental loop length on panoramic views from CBCT scans, which made it similar to studies using panoramic radiographs. Chen et al20  mentioned that they reconstructed part of the panoramic view along the inferior alveolar nerve canal, but no reference point of measuring the loop was found. Apostolakis and Brown31  counted the 0.3-mm vertical cross-section slices to evaluate the length of the loop, and we found it difficult to identify the most anterior part of the mental nerve on the cross-section views, especially when the bone density was poor.15  The method we used in our study was to locate the mental foramen and anterior loop on a single oblique transverse view. We believed that once the mandibular canal, the anterior loop, the incisive canal, and the mental foramen could be simultaneously visualized in the same view, the measurement would be more accurate. The presence of the anterior loop of mental nerve was defined as any part of the mental nerve located mesial (or anterior) to the mental foramen. In the present study, 85.2% prevalence of the loop was noted. This result was similar to the study of Neiva et al,33  who found 88% of anterior loop in skulls using a probe, and Kieser et al,34  who found 84% in cadavers. The reason that some studies showed a low prevalence (7% to 55%)10,32,35,36  might be the difficulty of clearly identifying the most anterior portion of the mental nerve. One disadvantage in the present study is that a medium-resolution CBCT with a scan time of 20 seconds and 0.4-mm voxel size was used. Higher-resolution scans with a scan time of 40 seconds and 0.25-mm voxel size might lead to a clearer image and decrease the errors of measurements. However, both intra- and interexaminer reliability were analyzed in our study, and the statistic result showed an excellent agreement. This result confirmed that the oblique transverse method was a simple and reliable way to measure the anterior loop on a CBCT scan.

Studies that have analyzed the anterior mental loop in cadavers tend to consist of populations with greater age and small sample sizes. Power analysis guided us to collect at least 61 patients in each group, with a total of 366 patients. To the best of our knowledge, this study consisted of the largest sample size of all studies to report on this topic. In the present study, equal subject numbers of different genders with a wide age range from 21 to 80 years were included. The statistical analysis showed that there was no difference between the right and left side or between genders. Uchida et al16,22  showed no difference between sides, but a larger AnLL was found in men. In our study, we had 5 times more subjects than the previous study, and men showed a mean AnLL of 1.51 mm, which is slightly larger than that of women (1.40 mm) but statistically not significant. Moreover, we found that the AnLL of the 21–40 year age group was significant larger than the 41–60 and 61–80 year groups. This is also consistent with Uchida et al22  and Ngeow et al,17  who indicated that the frequency of the anterior loops decreases with age. In 1986, Gershenson et al37  described that with loss of teeth and bone resorption, the mental foramen moves upward closer to the alveolar border. The mental nerve emerged from the mental foramen closer to or at the alveolar border, according to the degree of resorption. Therefore, when teeth are lost, bone resorption occurs, the mental foramen gets closer to the anterior part of the mental loop, and the AnLL decreases. Meanwhile, we found 3.28% of posterior edentulous in the age 21–40 year group, 20.08% in the 41–60 year group, and 27.87% in the 61–80 year group (Table 5). The mean AnLLs of the dentate and edentulous side were 1.55 mm and 1.00 mm, respectively. Therefore, we believe that when the age increases, the number of posteriorly edentulous mandibles increases, the bone resorption increases, and the AnLL and prevalence decrease.

Table 5

Posteriorly edentulous hemimandibles in each age group

Posteriorly edentulous hemimandibles in each age group
Posteriorly edentulous hemimandibles in each age group

Complications of surgical trauma or pressure on the mental nerve can result in neurosensory disturbances and altered sensation of the lower lip and chin after implant placement.13,38,39  Ellies and Hawker40  reported a retrospective analysis of a multicenter study. They found altered sensation of the mandibular alveolar nerve in 36% of patients after 2 weeks and 13% after 1 year. It has been suggested in the literature that the most distal aspect of an implant should be at least 1 mm,19  4 mm,10  or 6 mm21 anterior to the foramen to avoid injuring the inferior alveolar and/or mental nerves during an osteotomy based on findings of the prevalence and extent of the anterior loop of the mental nerve. In the present study, the largest AnLL was 6.67 mm. Moreover, the longest loop in the literature was reported by Neiva et al,33  being 11 mm, followed by Uchida et al16  with a length of 9 mm. For these cases, following the 1-, 4-, or 6-mm rule would lead us to injure the nerve when placing implants in close proximity to the mental foramina.

On the other hand, if we place every implant 6 mm anterior to the mental foramen, we limit the interforaminal space available for implant placement. The range of the AnLL found in our study is −2.87 mm to 6.67 mm. No studies in the literature have calculated the negative value when the anterior loop was not present. However, Kieser et al34  in 2002 described 5 patterns of emergence of the human mental nerve. Type 1, referred to as a posterior directed emergence, type 2 an anterior directed emergence, type 3 a right-angled pattern of emergence, type 4 to multiple foramina, and type 5 to the alveolus had resorbed, and no evaluation was possible. It is also important to recognize type 2 of mental nerve (for which the anterior loop has a negative value) because the surgeon can place the implant closer to the mental foramen and even posterior to the mental foramen. In the treatment of mandibular arch involving the interforaminal area, a full arch implant-supported restoration involving 4 to 5 implants is a good viable option. To place the implant closest to the mental foramen with concern on the anterior loop is the key factor for increasing the A-P spread and reducing distal cantilever.11,12  In addition, placing implants in mandibular partially dentate patients involving premolar and molar areas, the mental neurovascular bundle is usually the critical reference point during treatment planning. Therefore, the precise location of the mental loop must be identified using proper radiographic techniques before surgery. We recommended using the oblique transverse reconstruction modality on CBCT to accurately locate and measure the AnLL prior to the implant surgery.

After evaluating 366 CBCT scans of patients:

  • 1

    Of the scans, 85.2% revealed the presence of an anterior loop of the mental nerve.

  • 2

    A wide range of measurements existed for the AnLL, ranging from −2.87 mm to 6.67 mm, with a mean of 1.46 mm.

  • 3

    No statistically significant differences were found between the left- and right-side measurements or between genders, but the 21-40 year age group had a significantly larger AnLL than ages 41–60 and 61–80 years.

When placing implants in close proximity to the mental foramina, caution is recommended to avoid injury to the mental nerve and its neurovascular bundle. The anterior loop of the mental nerve becomes a critical surgical reference point during treatment planning. Because of the wide range of the AnLL observed in our study, no fixed distance mesially or anteriorly from the mental foramen should be considered to be a “safe” distance without the use of 3D imaging. Analyzing CBCT scans using the method described in this article can be a useful tool for avoiding implant surgical complications.

Abbreviations

2D

2-dimensional

3D

3-dimensional

AnLL

anterior loop length

ANOVA

analysis of variance

A-P spread

anterior-posterior spread

CBCT

cone-beam computerized tomography

CT

computerized tomography

MDCT

multi-detector computed tomography

RMSSE

root mean square standardized effect

The authors would like to thank Ashish Sharma, the residents, and faculty members at Advanced Education in Implant Dentistry, Loma Linda University School of Dentistry, for their involvement in the study and Ching-Ho Leu and Udochukwu Oyoyo for their assistance with the statistical analysis.

1
Misch
CE.
Diagnostic imaging and techniques
.
In
:
Contemporary Implant Dentistry. 3rd ed
.
St Louis, Mo
:
Mosby; 38–67
.
2
Harris
D
,
Buser
D
,
Dula
K
,
et al
.
E.A.O. guidelines of the use of diagnostic imaging in implant dentistry: a consensus workshop organized by the European Association for Osseointegration in Trinity College Dublin
.
Clin Oral Implants Res
.
2002
;
14
:
464
471
.
3
Frei
C
,
Buser
D
,
Dula
K.
Study on the necessity for cross-section imaging of the posterior mandible for treatment planning of standard cases in implant dentistry
.
Clin Oral Implants Res
.
2004
;
15
:
490
497
.
4
Tyndall
DA
,
Price
JB
,
Tetradis
S
,
Ganz
SD
,
Hildebolt
C
,
Scarfe
WC
;
American Academy of Oral and Maxillofacial Radiology. Position statement of the American Academy of Oral and Maxillofacial Radiology on selection criteria for the use of radiology in dental implantology with emphasis on cone beam computed tomography
.
Oral Surg Oral Med Oral Pathol Oral Radiol
.
2012
;
113
:
817
826
.
5
Reddy
MS
,
Mayfield-Donahoo
T
,
Vanderven
FJ
,
Jeffcoat
MK.
A comparison of the diagnostic advantages of panoramic radiography and computed tomography scanning for placement of root form dental implants
.
Clin Oral Implants Res
.
1994
;
5
:
229
238
6
Schropp
L
,
Wenzel
A
,
Kostopoulos
L.
Impact of conventional tomography on prediction of the appropriate implant size
.
Oral Surg Oral Med Oral Pathol
.
2001
;
92
:
458
463
.
7
DuBrul
EL.
Sicher's Oral Anatomy
.
7th ed
.
St Louis
,
Mosby
;
1980
:
449
450
8
Mardinger
O
,
Chaushu
G
,
Arensburg
B
,
Taicher
S
,
KaffeI. Anterior loop of the mental canal: an anatomical-radiologic study
.
Implant Dent
.
2000
;
9
:
120
123
.
9
Serhal
CB
,
Steenberghe
DV
,
Quirynen
M
,
Jacobs
R.
Localization of the mandibular canal using conventional spiral tomography: a human cadaver study
.
Clin Oral Implants Res
.
2001
;
12
:
230
236
.
10
Kuzmanovic
DV
,
Payne
AGT
,
Kieser
JA
,
Dias
GJ.
Anterior loop of the mental nerve: a morphological and radiographic study
.
Clin Oral Implants Res
.
2003
;
14
:
464
471
.
11
English
CE.
Critical A-P spread
.
Implant Soc
.
1990
;
1
(
1
):
2
3
.
12
Rangert
B
,
Jemt
T
,
Jörneus
L.
Forces and moments on Branemark implants
.
Int J Oral Maxillofac Implants
.
1989
;
4
:
241
247
.
13
Kraut
RA
,
Chahal
O.
Management of patients with trigeminal nerve injuries after mandibular implant placement
.
J Am Dent Assoc
.
2002
;
133
:
1351
1354
.
14
Arzouman
MJ
,
Otis
L
,
Kipnis
V
,
Levine
D.
Observations of the anterior loop of the inferior alveolar canal
.
Int J Oral Maxillofac Implants
.
1993
;
8
:
295
300
.
15
Kaya
Y
,
Sencimen
M
,
Sahin
S
,
Okcu
KM
,
Dogan
N
,
Bahcecitapar
M.
Retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and spiral computerized tomography
.
Int J Oral Maxillofac Implants
.
2008
;
23
:
919
925
.
16
Uchida
Y
,
Noguchi
N
,
Goto
M
,
et al
.
Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography
.
J Oral Maxillofac Surg
.
2009
;
67
:
744
750
.
17
Ngeow
WC
,
Dionysius
DD
,
Ishak
H
,
Nambiar
P.
A radiographic study on the visualization of the anterior loop in dentate subjects of different age groups
.
J Oral Sci
.
2009
;
51
:
231
237
.
18
Gerlach
NL
,
Meijer
GJ
,
Maal
TJ
,
et al
.
Reproducibility of 3 different tracing methods based on cone beam computed tomography in determining the anatomical position of the mandibular canal
.
J Oral Maxillofac Surg
.
2010
;
68
:
811
817
.
19
Bavitz
JB
,
Harn
SD
,
Hansen
CA
,
Lang
M.
An anatomical study of mental neurovascular bundle-implant relationships
.
Int J Oral Maxillofac Implants
.
1993
;
8
:
563
567
.
20
Chen
JC
,
Lin
LM
,
Geist
JR
,
Chen
JY
,
Chen
CH
,
Chen
YK.
A retrospective comparison of the location and diameter of the inferior alveolar canal at the mental foramen and length of the anterior loop between American and Taiwanese cohorts using CBCT
.
Surg Radiol Anat
.
2013
;
35
:
11
18
.
21
Solar
P
,
Ulm
C
,
Frey
G
,
et al
.
A classification of the intraosseous path of the mental nerve
.
Int J Oral Maxillofac Implants
.
1994
;
9
:
339
344
.
22
Uchida
Y
,
Yamashita
Y
,
Goto
M
,
Hanihara
T.
Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region
.
J Oral Maxillofac Surg
.
2007
;
65
:
1772
1779
.
23
Misch
CE
,
Crawford
EA.
Predictable mandibular nerve location–a clinical zone of safety
.
Int J Oral Implantol
.
1990
;
7
:
9
17
24
Yosue
T
,
Brooks
SL.
The appearance of mental foramina on panoramic radiographs. I. Evaluation of patients
.
Oral Surg Oral Med Oral Pathol
.
1989
;
68
:
360
364
.
25
Sukovic
P.
Cone beam computed tomography in craniofacial imaging
.
Orthod Craniofac Res
.
2003
;
6
(
suppl 1
):
31
36
.
26
Clark
DE
,
Danforth
RA
,
Barnes
RW
,
Burtch
ML.
Radiation absorbed from dental implant radiography: a comparison of linear tomography, CT scan, and panoramic and intra-oral techniques
.
J Oral Implantol
.
1990
;
16
:
156
164
.
27
Tsiklakis
K
,
Donta
C
,
Gavala
S
,
Karayianni
K
,
Kamenopoulou
V
,
Hourdakis
CJ.
Dose reduction in maxillofacial imaging using low dose cone beam CT
.
Eur J Radiol
.
2005
;
56
:
413
417
.
28
Poeschl
PW
,
Schmidt
N
,
Guevara-Rojas
G
,
et al
.
Comparison of cone-beam and conventional multislice computed tomography for image-guided dental implant planning
.
Clin Oral Investig
.
2013
;
17
:
317
324
.
29
Al-Ekrish
AA
,
Ekram
M.
A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions
.
Dentomaxillofac Radiol
.
2011
;
40
:
67
75
.
30
Santana
RR
,
Lozada
J
,
Kleinman
A
,
Al-Ardah
A
,
Herford
A
,
Chen
JW.
Accuracy of cone beam computerized tomography and a three-dimensional stereolithographic model in identifying the anterior loop of the mental nerve: a study on cadavers
.
J Oral Implantol
.
2012
;
38
:
668
676
.
31
Apostolakis
D
,
Brown
JE.
The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging
.
Clin Oral Implants Res
.
2012
;
23
:
1022
1030
.
32
Rosa
MB
,
Sotto-Maior
BS
,
Machado Vde C, Francischone CE. Retrospective study of the anterior loop of the inferior alveolar nerve and the incisive canal using cone beam computed tomography
.
Int J Oral Maxillofac Implants
.
2013
;
28
:
388
392
.
33
Neiva
RF
,
Gapski
R
,
Wang
HL.
Morphometric analysis of implant-related anatomy in Caucasian skulls
.
J Periodontol
.
2004
;
75
:
1061
1067
.
34
Kieser
J
,
Kuzmanovic
D
,
Payne
A
,
Dennison
J
,
Herbison
P.
Patterns of emergence of the human mental nerve
.
Arch Oral Biol
.
2002
;
47
:
743
747
.
35
Jacobs
R
,
Mraiwa
N
,
vanSteenberghe
D
,
Gijbels
F
,
Quirynen
M.
Appearance, location, course, and morphology of the mandibular incisive canal: an assessment on spiral CT scan
.
Dentomaxillofac Radiol
.
2002
;
31
:
322
327
.
36
Watanabe
H
,
Mohammad Abdul
M
,
Kurabayashi
T
,
Aoki
H.
Mandible size and morphology determined with CT on a premise of dental implant operation
.
Surg Radiol Anat
.
2010
;
32
:
343
349
.
37
Gershenson
A
,
Nathan
H
,
Luchansky
E.
Mental foramen and mental nerve: changes with age
.
Acta Anat (Basel)
.
1986
;
126
:
21
28
.
38
Walton
JN.
Altered sensation associated with implants in the anterior mandible: a prospective study
.
J Prosthet Dent
.
2000
;
83
:
443
449
.
39
Wismeijer
D
,
van Waas
MA
,
Vermeeren
JI
,
Kalk
W.
Patients' perception of sensory disturbances of the mental nerve before and after implant surgery: a prospective study of 110 patients
.
Br J Oral Maxillofac Surg
.
1997
;
35
:
254
259
.
40
Ellies
LG
,
Hawker
PB.
The prevalence of altered sensation associated with implant surgery
.
Int J Oral Maxillofac Implants
.
1993
;
8
:
674
679
.