Zirconia is becoming increasingly used as a restorative material for implant-supported restorations; however, information is lacking with respect to the minimum thickness of zirconia surrounding the implant components. The purpose of this study is to evaluate the resistance to fracture of different thicknesses of zirconia luted to implant components. Thirty cylinders of zirconia (Prettau, Zirkonzahn) with 13-mm height, designed with indented occlusal surface for loading, and varying wall thicknesses (0.5 mm, 1 mm, 1.5 mm; n = 10/group) were milled using a computer-aided design/computer-aided manufacturing system (Modellier, Zirkonzahn), after which they were sintered. Titanium temporary cylinders (ITCS41, Biomet3i) were attached to 30 implant analogs (ILA20, Biomet3i) that were embedded into polymethylmethacrylate blocks (Palapress Vario, Heraeus Kulzer) with dimensions of 4.5 × 1.8 × 2 cm. Zirconia specimens were cemented to the titanium cylinders using a self-adhesive, dual-cure resin cement (Panavia SA, Kuraray). Load to failure test was performed under compression until fracture using a universal testing machine (Instron5965, Instron) at a crosshead speed of 0.5 mm/min and measured in N (Newton). Statistical analysis was performed using 1-way analysis of variance and Tukey B test at α = .05 (SPSS19, IBM). Mean load to failure was 1059.94 N, 2019.46 N, and 4074.79 N for groups 0.5 mm, 1 mm, and 1.5 mm, respectively. Values were significantly different between the groups (P < .05). Study limitations are that it is in vitro, specimens do not replicate tooth dimensions, and forces are static and directed toward the occlusal portion of each specimen. Within these limitations and considering the average human bite force, a thickness of 0.5 mm to 1 mm of this particular type of zirconia around this type of implant component can avoid fracture with these dimensions.

In the rapidly changing field of dentistry, the drive to achieve an esthetic outcome while maintaining the strength and durability of a restoration has resulted in zirconia being selected as a material of choice in a growing number of indications.1,2 

Zirconia is a polycrystalline ceramic that exists in 3 allotropic forms. Upon cooling, zirconia goes through phase changes from cubic (>2370°C) to tetragonal (1170°C–2370°C) and finally to a monoclinic phase.3 

For dental restorations, the tetragonal phase is the most desirable because of its excellent physical and superior optical properties when compared with metallic restorative materials. The tetragonal form of zirconia is unstable at room temperature; however, this can be mitigated by adding a small amount of yttria to stabilize this allotropic form at room temperature.4 

The major advantage of zirconia is high fracture resistance, which is represented by the high flexural strength (900–1200 MPa) and fracture toughness of 9–10 MPa.m½ compared with other all-ceramic core materials, whose flexural strength (alumina-based glass infiltrated ceramic, 400 Mpa; densely sintered alumina, 650 MPa) and fracture toughness (alumina-based glass infiltrated ceramic, 4.78 MPa.m½; densely sintered alumina, 4.48 MPa.m½) are inferior.510 

These physical properties can be attributed to “transformation toughening,” which can be described as an allotropic change from tetragonal to monoclinic when stress is applied.1,4,11  This phenomenon results in 4.4% volumetric increase of the grains surrounding the crack tip, which retards crack propagation.11 

The use of zirconia has been growing in single- and multiple-unit implant-supported restorations. The most commonly reported clinical complications with zirconia-based restorations has been reported to be chipping of layered porcelain.1214  The failure of the zirconia framework itself has been sparsely reported in the literature.15  Recently, publications are emerging that describe use of implant-supported, multi-unit, complete-arch restorations with zirconia frameworks.5,1620  Many authors describe complete-arch implant-supported zirconia restorations in the literature with various framework designs.1517,2126 

Since few reports of framework fracture exist, monolithic zirconia restorations are being used both with tooth-borne or implant-supported restorations to maximize the durability of the restoration and to avoid complication of porcelain chipping.17,26  Although it is tempting to extrapolate from the evidence of the strength of monolithic zirconia, there is limited information available to support widespread clinical use for implant-supported zirconia prostheses.

When machining zirconia restorations, it is more common to use a soft machining process in which the non- or partially-sintered zirconia is machined. This reduces wear on the machining bits used to form the restoration and reduces the induction of cracks upon machining. After formation of the restoration, it is sintered to affect a phase change to the stronger tetragonal allotrope. The sintering process causes an approximate volumetric shrinkage of 25%. Although compensated for with a computer algorithm, this step can cause a misfit from the zirconia structure to the implant. This can be compensated by cementing metal abutments into the implant zirconia framework to serve as a connection to the implant platform. This also avoids complications of forces from the screw to the zirconia frame and of differential wear that arises when zirconia has a direct connection to the implant platform.2730 

However, information is still lacking regarding the optimal wall thickness of zirconia surrounding the abutment components (Figures 1 and 2). Therefore, this study was conducted to isolate the factor of material thickness around the abutment components by using a simplified specimen design.

Figures 1–5

Figure 1. Example fracture of zirconia framework around implant abutment. Figure 2. Example fracture of zirconia framework around implant abutment. Figure 3. Load to fracture data (N) of different zirconia wall thicknesses. Figure 4. Fractured specimen under load. Figure 5. Fractured 1-mm specimen.

Figures 1–5

Figure 1. Example fracture of zirconia framework around implant abutment. Figure 2. Example fracture of zirconia framework around implant abutment. Figure 3. Load to fracture data (N) of different zirconia wall thicknesses. Figure 4. Fractured specimen under load. Figure 5. Fractured 1-mm specimen.

Close modal

The purpose of this study is to evaluate the resistance to fracture of zirconia with different wall thicknesses luted to implant components. This may provide information toward the design of zirconia prostheses for implant-supported restorations. The null hypothesis is that there will not be any significant differences of fracture resistance between the varying thicknesses of zirconia luted to implant components.

Thirty cylinders of monolithic Yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) zirconia of 13-mm height and varying wall thicknesses (0.5 mm, 1 mm, 1.5 mm) were designed using computer-aided design (CAD) software (Modellier Software, Zirkonzahn, Gais, Switzerland). All specimens were designed with an indented occlusal surface for experimental loading. Samples were milled out of a monolithic 18-mm height zirconia block (Prettau Zirconia, Zirkonzahn) using a 5 + 1 axis milling unit (M5, Zirkonzahn) and sintered according to the manufacturer's recommendations. The final thickness was confirmed using a digital caliper (Absolute Digimatic Caliper, Mitutoyou, Sakada, Japan).

Thirty external hex implant analogs (ILA20, Biomet 3i, Palm Beach Gardens, Fla) were embedded into self-curing acrylic resin (Palapress Vario, Heraeus Kulzer, Wehrheim, Germany) with ratio of 10 g powder:7 mL liquid using a silicone mold (dimensions: 4.5 cm × 1.8 cm × 2 cm). Titanium hexed abutment screws were torqued to 20 Ncm to connect titanium temporary cylinders (ITCS41, Biomet 3i LLC) to the implant analogs according to the manufacturer's recommendations. The zirconia cylinders were cemented to the titanium cylinders using a self-adhesive, dual-cure resin cement (Panavia SA, Kuraray, Tokyo, Japan). Excess cement was removed with microbrushes, and the specimen was light cured using a light-emitting diode–curing unit (10 seconds, 1000 mW/cm2; Valo, Ultradent, South Jordan, Utah). Prepared specimens were kept in room temperature in a dry environment for 24 hours before fracture testing was performed.

All specimens were subjected to load to failure test under compression until fracture using a universal testing machine (Instron 5965, Instron, Norwood, Mass). Fracture strength data were recorded in Newton (N) by the computer controlling the universal testing machine and was exported to an Excel spreadsheet (Excel 2016, Microsoft, Redmond, Wash). Data for the dependent variable (wall thickness) and independent variable (fracture strength) were entered in separate columns and subsequently transferred to a statistical software (SPSS 19, IBM, Armonk, NY) for further analysis. All tested specimens were included, and data were not transformed for analysis.31 

The primary objective of this investigation was to evaluate the fracture strength of milled, monolithic Y-TZP zirconia cylinders with varying wall thickness (0.5, 1.0, and 1.5 mm), which were adhesively cemented to titanium temporary cylinders. One-way independent analysis of variance (ANOVA) with post hoc Tukey B test was used to evaluate differences between the 3 groups differing in wall thickness.

Mean load to failure was 1059.94 N, 2019.46 N, and 4074.79 N for groups 0.5 mm, 1 mm, and 1.5 mm, respectively (Table 1, Figure 3). Load to failure values ranged from a minimum of 503.22 N in the 0.5-mm group to 4647.75 N in the 1.5-mm group.

Table 1

Fracture strength data for each zirconia wall thickness group: sample size, mean, minimum, and maximum fracture strength values (N)*

Fracture strength data for each zirconia wall thickness group: sample size, mean, minimum, and maximum fracture strength values (N)*
Fracture strength data for each zirconia wall thickness group: sample size, mean, minimum, and maximum fracture strength values (N)*

In all samples tested, screw loosening was noted after load to fracture. None of the lab analogs or the temporary abutments were damaged when visually inspected. A fractured specimen is shown in Figures 4 and 5.

Prerequisites for ANOVA (normality and homoscedasticity) according to Kolmogorov-Smirnov and Levene tests were met (P > .05). ANOVA showed an overall significant difference between the groups (F = 135.43, df = 2, P < .001). Groupwise comparison using Tukey B test showed a significant difference between the groups (P < .05; Table 2).

Table 2

Summary output for one-way independent analysis of variance (ANOVA)

Summary output for one-way independent analysis of variance (ANOVA)
Summary output for one-way independent analysis of variance (ANOVA)

The mathematical assumptions for the Tukey test were (1) normal distribution of data, (2) homogeneity of variance (homoscedasticity), and (3) independence of observations within and among the groups. All assumptions were met. While normality of distribution was confirmed by Kolmogorov-Smirnov test (P = .200), homogeneity of variance was confirmed by Levene test (P = .648). Since each specimen was fabricated separately by CAD/computer-aided manufacturing (CAM) procedures, independence of observation within and among groups is ensured (Tables 3 and 4).

Table 3

Output for test of normality (Kolmogorov-Smirnov)*

Output for test of normality (Kolmogorov-Smirnov)*
Output for test of normality (Kolmogorov-Smirnov)*
Table 4

Output for test of homogoneneity of variances (Levene)

Output for test of homogoneneity of variances (Levene)
Output for test of homogoneneity of variances (Levene)

The null hypothesis was rejected. There is a significant difference of fracture resistance between the varying thicknesses of zirconia around implant components.

Although long-term clinical data on the survival and complications of implant-supported zirconia prostheses are limited, some in vitro studies have reported fracture resistance of zirconia abutments to be close to 593 N in single implant-supported restorations.5,32  However, in comparing our experiment with previous studies, we have to note some differences in specimen design. Att et al32  had zirconia abutments with metal inserts for connection to the implants onto which anatomic zirconia crowns were cemented. Unlike this study, our experimental design consists of a direct connection of the zirconia restoration to titanium abutment. With these differences in mind, we can extrapolate from the fracture pattern of the cervical portion of zirconia in the study by Att et al that this is the area of highest stress concentration, which is vulnerable to fracture because of the minimal volume of zirconia.32 

To investigate the area vulnerable to fracture around implant-supported zirconia restorations, zirconia cylinders with varying thicknesses around titanium abutments were tested in our study. The results suggest keeping a minimum circumferential thickness of 0.5 mm to 1 mm of monolithic zirconia may be sufficient to withstand the average molar occlusal force in humans (597 N in women, 847 N in men).33  The average fracture resistance of the 0.5-mm group was 1059.94 N, which is above the average molar occlusal force in humans. However, we must consider the lowest fracture resistance of 503.22 N, which was also present in the 0.5-mm group. This suggests that increasing thicknesses will significantly increase strength, and 0.5 mm might be the thinnest acceptable thickness for clinical use. A possible explanation for the lowest fracture strength of the 0.5-mm group could be related to confounding factors such as milling discrepancies of thin sample of zirconia.

Despite the lack of long-term clinical evidence, more and more clinicians are choosing to restore their patients with complete-arch implant-supported zirconia restorations.34  A recent systematic review by Abdulmajeed et al included 9 studies for the survival of complete-arch implant-supported monolithic zirconia fixed dental prostheses (FDPs) and concluded that implant-supported zirconia restorations have high survival in the short term but acknowledged the absence of long-term clinical evidence.35,36  Even though catastrophic failure of complete-arch zirconia restorations has not been commonly reported, our experiment was undertaken to simplify the implant-supported zirconia restoration design into a single unit for the purpose of isolating and testing the effect of varying thicknesses on the fracture strength of zirconia.

Currently, most long-term clinical data come from Larsson et al,37  who performed an 8-year follow-up on 9 patients who were restored with complete-arch zirconia cemented onto titanium abutments. Although not a prospective study, after 8 years, none of the restorations showed bulk fracture of framework, with fracture of veneering porcelain in 8 patients.

Others have also reported in case reports regarding their experiences with implant-supported zirconia FDPs, with modified framework designs to minimize porcelain fracture.19,20  Goldberg et al,23  Mehra et al,25  and Venezia et al26  have maintained the occluding or functioning surfaces in full zirconia layering only the facial surfaces with feldspathic porcelain, reducing the chances of veneering material fracture. These results show a promising future for implant-supported complete-arch zirconia-based FDPs as an acceptable treatment alternative, and therefore, a more systemic approach to isolating the design factor for implant-supported zirconia restorations needs to be investigated with in vitro studies. Although different from in vivo studies, in vitro studies that test framework design factors may build the pathway for consistent framework design in future prospective clinical trials.

Limitations of this study include an in vitro experimental design with specimen morphology deviating from a crown morphology, and the force applied may be different from a clinical scenario in which a smaller area or asymmetric configuration of loading may cause increased stress concentration compared with a vertical static load without aging to a single-unit cylinder of zirconia. There are other confounding factors to consider that are possible effects of a different screw hole morphology on the loading area and thus different crack propagation points leading to a fracture. This study is limited to monolithic zirconia screw-retained implant restorations for the specific brand (Prettau Zirconia, Zirkonzahn); therefore, one should be cautious in relating the results to other zirconia implant crowns with porcelain additions. Future experiments testing varying thicknesses under cyclic loading as well as fracture strength after induced low-temperature degradation are under way to provide further information.

Considering the average occluding forces in humans, this study suggests that a minimum thickness of 0.5 mm to 1 mm of this particular type of zirconia surrounding the implant abutment may be sufficient to resist fracture of the zirconia prosthesis around this area of stress and minimal volume of material.

Abbreviations

Abbreviations
ANOVA:

analysis of variance

CAD/CAM:

computer-aided design/computer-aided manufacturing

FDP:

Fixed dental prosthesis

N:

Newton

Y-TZP:

Yttria-stabilized tetragonal zirconia polycrystal

The authors thank Emil Sahakian and Kazunari Takanashi, RDT, at the Burbank Dental Lab, Los Angeles, Calif, for milling the samples. The study was supported in part by an American Academy of Implant Dentistry Foundation student research grant.

The authors declare that they have no conflicts of interest.

1
Manicone
PF,
Rossi Iommetti
P,
Raffaelli
L.
An overview of zirconia ceramics: basic properties and clinical applications
.
J Dent
.
2007
;
35
:
819
826
.
2
Sailer
I,
Philipp
A,
Zembic
A,
Pjetursson
BE,
Hammerle
CH,
Zwahlen
M.
A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions
.
Clin Oral Implants Res
.
2009
;
20
(
suppl 4
):
4
31
.
3
Denry
I,
Kelly
JR.
State of the art of zirconia for dental applications
.
Dent Mater
.
2008
;
24
:
299
307
.
4
Kelly
JR,
Denry
I.
Stabilized zirconia as a structural ceramic: an overview
.
Dent Mater
.
2008
;
24
:
289
298
.
5
Guess
PC,
Att
W,
Strub
JR.
Zirconia in fixed implant prosthodontics
.
Clin Implant Dent Relat Res
.
2012
;
14
:
633
645
.
6
White
SNM,
Miklus
VGD,
McLaren
EAD,
Lang
LAD,
Caputo
AAP.
Flexural strength of a layered zirconia and porcelain dental all-ceramic system
.
J Prosthet Dent
.
2005
;
94
:
125
131
.
7
O'Brien
WJ.
ed
.
Dental porcelain
.
In
:
Dental Materials and Their Selection. 4th ed
.
Hanover
Park.
Ill
:
Quintessence;
2008
:
212
229
.
8
Yilmaz
H,
Aydin
C,
Gul
BE.
Flexural strength and fracture toughness of dental core ceramics
.
J Prosthet Dent
.
2007
;
98
:
120
128
.
9
Guazzato
M,
Albakry
M,
Ringer
SP,
Swain
MV.
Strength, Fracture toughness and microstructure of a selection of all-ceramic materials. part I. pressable and alumina glass-infiltrated ceramics
.
Dent Mater
.
2004
;
20
:
441
448
.
10
Wagner
WC,
Chu
TM.
Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics
.
J Prosthet Dent
.
1996
;
76
:
140
144
.
11
Piconi
C,
Maccauro
G.
Zirconia as a ceramic biomaterial
.
Biomaterials
.
1999
;
20
:
1
25
.
12
Benetti
P,
Kelly
JR,
Della Bona
A.
Analysis of thermal distributions in veneered zirconia and metal restorations during firing
.
Dent Mater
.
2013
;
29
:
1166
1172
.
13
Guess
PC,
Bonfante
EA,
Silva
NR,
Coelho
PG,
Thompson
VP.
Effect of core design and veneering technique on damage and reliability of Y-TZP-supported crowns
.
Dent Mater
.
2013
;
29
:
307
316
.
14
Gabbert
O,
Ohlmann
B,
Schmitter
M,
Gilde
H,
Ruef
T,
Rammelsberg
P.
Fracture behaviour of zirconia ceramic cantilever fixed dental prostheses in vitro
.
Acta Odontol Scand
.
2008
;
66
:
200
206
.
15
Chang
JS,
Ji
W,
Choi
CH,
Kim
S.
Catastrophic failure of a monolithic zirconia prosthesis
.
J Prosthet Dent
.
2015
;
113
:
86
90
.
16
Cho
Y,
Raigrodski
AJ.
The rehabilitation of an edentulous mandible with a CAD/CAM zirconia framework and heat-pressed lithium disilicate ceramic crowns: a clinical report
.
J Prosthet Dent
.
2014
;
111
:
443
447
.
17
Rojas-Vizcaya
F.
Full zirconia fixed detachable implant-retained restorations manufactured from monolithic zirconia: clinical report after two years in service
.
J Prosthodont
.
2011
;
20
:
570
576
.
18
Larsson
C,
Wennerberg
A.
The clinical success of zirconia-based crowns: a systematic review
.
Int J Prosthodont
.
2014
;
27
:
33
43
.
19
Cheng
C-W,
Chien
C-H,
Chen
C-J,
Papaspyridakos
P.
Complete-mouth implant rehabilitation with modified monolithic zirconia implant-supported fixed dental prostheses and an immediate-loading protocol: a clinical report
.
J Prosthet Dent
.
2013
;
109
:
347
352
.
20
Puri S, Parciak EC, Kattadiyil MT.
Complete mouth reconstruction with implant-supported fixed partial dental prostheses fabricated with zirconia frameworks: a 4-year clinical follow-up
.
J Prosthet Dent
.
2014
;
112
:
397
401
.
21
Altarawneh
S,
Limmer
B,
Reside
GJ,
Cooper
L.
Dual jaw treatment of edentulism using implant-supported monolithic zirconia fixed prostheses
.
J Esthet Restor Dent
.
2015
;
27
:
63
70
.
22
Carames
J.
Tovar Suinaga L, Yu YC, Perez A, Kang M. Clinical advantages and limitations of monolithic zirconia restorations full arch implant supported reconstruction: case series
.
Int J Dent
.
2015
;
2015
:
1
7
.
23
Goldberg
J,
Torbati
A,
Amir
A,
Chee
W.
Implant-supported full-arch zirconia fixed dental prostheses for the rehabilitation of a patient with a failing dentition
.
Quint Dent Tech
.
2016
;
39
:
179
195
.
24
Limmer
B,
Sanders
AE,
Reside
G,
Cooper
LF.
Complications and patient-centered outcomes with an implant-supported monolithic zirconia fixed dental prosthesis: 1 year results
.
J Prosthodont
.
2014
;
23
:
267
275
.
25
Mehra
M,
Vahidi
F.
Complete mouth implant rehabilitation with a zirconia ceramic system: a clinical report
.
J Prosthet Dent
.
2014
;
112
:
1
4
.
26
Venezia
P,
Torsello
F,
Cavalcanti
R,
D'Amato
S.
Retrospective analysis of 26 complete-arch implant-supported monolithic zirconia prostheses with feldspathic porcelain veneering limited to the facial surface
.
J Prosthet Dent
.
2015
;
114
:
506
512
.
27
Truninger
TC,
Stawarczyk
B,
Leutert
CR,
Sailer
TR,
Hammerle
CH,
Sailer
I.
Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation
.
Clin Oral Implants Res
.
2012
;
23
:
12
18
.
28
Mitsias
M,
Silva
N,
Pines
M,
Stappert
C,
Thompson
V.
Reliability and fatigue damage modes of zirconia and titanium abutments
.
Int J Prosthodont
.
2010
;
23
:
56
59
.
29
Taylor
TD,
Klotz
MW,
Lawton
RA.
Titanium tattooing associated with zirconia implant abutments: a clinical report of two cases
.
Int J Oral Maxillofac Implants
.
2014
;
29
:
958
960
.
30
Garine
W,
Funkenbusch
P,
Ercoli
C,
Wodenscheck
J,
Murphy
W.
Measurement of the rotational misfit and implant-abutment gap of all-ceramic abutments
.
Int J Oral Maxillofac Implants
.
2007
;
22
:
928
938
.
31
IBM
Corp.
IBM SPSS Statistics for Windows, Version 19.0
.
Armonk, NY
:
IBM Corp;
2010
.
32
Att
W,
Kurun
S,
Gerds
T,
Strub
JR.
Fracture resistance of single-tooth implant-supported all-ceramic restorations after exposure to the artificial mouth
.
J Oral Rehabil
.
2006
;
33
:
380
386
.
33
Waltimo
A,
Kononen
M.
A novel bite force recorder and maximal isometric bite force values for healthy young adult
.
Scand J Dent Res
.
1993
;
101
:
171
175
.
34
Larsson
C,
Vult von Steyern
P,
Nilner
K.
A prospective study of implant-supoported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: three-year results
.
Int J Prosthodont
.
2010
;
23
:
364
369
.
35
Abdulmajeed
A,
Lim
K,
Narhi
T,
Cooper
L.
Complete-arch implant-supported monolithic zirconia fixed dental prostheses: a systematic review
.
J Prosthet Dent
.
2016
;
115
:
672
677
.
36
Le
M,
Papia
E,
Larsson
C.
The clinical success of tooth- and implant-supported zirconia-based fixed dental prostheses: a systematic review
.
J Oral Rehabil
.
2015
;
42
:
467
480
.
37
Larsson
C.
Vult Von Steyern P. Implant-supported full-arch zirconia-based mandibular fixed dental prostheses: eight-year results from a clinical pilot study
.
Acta Odontol Scand
.
2013
;
71
:
1118
1122
.