Clinical Relevance
Nanofilled resin composite showed excellent clinical performance, similar to microhybrid and packable composites after 12-months.
SUMMARY
This study compared the clinical performance of a nanofilled resin composite for posterior restorations with 2 microhybrid and 1 packable composite after 12 months of clinical service. Forty-two patients with at least 5 Class I or II restorations under occlusion were enrolled in this study. A total of 148 restorations were placed, 25% for each material (Filtek Supreme, Pyramid, Esthet-X or Tetric Ceram). Two calibrated operators placed all restorations, according to the manufacturers' instructions. One week later, the restorations were finished/polished. Two independent examiners evaluated the restorations at baseline and after 12 months according to the USPHS modified criteria. All patients attended the 12-month recall and 148 restorations were evaluated. Friedman repeated measures analysis of variance by rank and Wilcoxon sign-ranked test for pair-wise comparison was used for data analysis (α=0.05). All materials showed only minor modifications, and no differences were detected between their performance at baseline and after 12 months. After 1 year, the nanofilled resin composite showed similar performance to the other packable and microhybrid resin composites.
INTRODUCTION
The majority of resin composites on the market are called universal hybrid or microhybrid resin composites. The improved esthetics provided by these materials, due to the smoother surface obtained after polishing and higher wear resistance (<10 μm/year), led to their recommendation for placement in anterior and posterior teeth (Baratieri, Araujo & Monteiro, 1993). In many clinical studies, several hybrid resin composites with these characteristics showed excellent clinical performance (Leinfelder, 1995; Abdalla & Alhadainy, 1996; Schoch & others, 1999; Perdigão, Geraldelli & Hodges, 2003; Busato & others, 2001).
However, there are controversial findings regarding the performance of hybrid composites in anterior teeth. While some studies demonstrated that hybrid and microfilled composites have similar performance in esthetic cavities, others concluded that microfilled composites are the best option for anterior cavities because of their high translucency, high polish and polish retention (van Dijken, 1986; van der Veen, Pilon & Henty, 1989; Browning, Brackett & Gilpatrick, 2000; Geitel & others, 2004).
However, the degree of complexity of resin composite restoration placement and curing is blamed for perceived higher levels of secondary caries or postoperative sensitivity (Leinfelder, Bayne & Swift, 1999). In the face of these difficulties, changes in the handling characteristics of resin composites were made to improve composite placement; and several products, called packable resin composites, are available for posterior use. This category of materials is rather inhomogeneous in terms of mechanical and physical data (Ferracane, Choi & Condon, 1999; Choi & others, 2000; Abe & others, 2001) and esthetic properties (Ryba, Dunn & Murchison, 2002; Reis & others, 2003; Borges & others, 2004).
Recently, a new category of resin composites were developed and named nanofilled composites. Restorative composite systems made by the use of nanotechnology can offer high translucency, high polish and polish retention similar to that of microfilled composites while maintaining physical properties and wear equivalent to several hybrid composites (Mitra, Holmes & Wu, 2003). Unfortunately, to the extent of the authors' knowledge, there is no clinical study that has attempted to compare the performance of this new category of resin composites with other available composites for posterior use, which was the aim of this investigation.
METHODS AND MATERIALS
The research protocol was submitted to the Ethics Committee. Once the method was approved, dental students from the School of Dentistry (University of Oeste de Santa Catarina) were selected. The resin composites employed in this study were: Filtek-Supreme (3M ESPE, St Paul, MN, USA), a nanofilled resin composite; Pyramid (BISCO, Schaumburg, IL, USA), a packable resin composite and Esthet-X (Caulk-DeTrey Dentsply, Konstanz, Germany) and Tetric Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) as microhybrid composites (Table 1).
Each patient required at least 5 Class I or Class II restorations. All patients had complete and normal occlusion. According to the treatment rules at the School of Dentistry, Department of Dental Materials and Operative Dentistry, University of Oeste de Santa Catarina, all patients received oral hygiene instructions before operative treatment was performed. Patients with extremely poor oral hygiene, heavy bruxism habits or periodontal problems were excluded. Most restorations replaced existing amalgams for esthetic reasons.
The restorative procedure was initiated using rubber dam isolation. The cavity design (restricted to the elimination of carious tissue) was prepared using stainless steel burs (#329, 330 and/or 245; KG Sorensen, Barueri, São Paulo, Brazil). The dentin in deeper cavities was covered with calcium hydroxide Dycal (Caulk-DeTrey) and/or glass ionomer cement Vitrebond (3M ESPE).
Randomization of the materials was performed on each patient by tossing a coin. However, interference in the randomization procedure within patients was performed in order to equally distribute materials into some important variables such as tooth type and position, restoration class and size, and occlusion in such a way that minimized the influence of those factors (Bryant & Hodge, 1994). Although all the restorations were of moderate size, as defined by Wilson, Smith and Wilson (1986), fewer than 5% of the restorations extended less than one-quarter of the way up the culpal slopes.
The adhesive systems from the same manufacturer for each resin composite were employed (Table 2). The adhesive application followed the manufacturers' directions (Table 2). Placement of resin composites followed the incremental technique (2-mm thick layers). The resin composite was adapted with a flat-faced or elliptical condenser and light-cured for 40 seconds using an Optilux 501 light-curing unit (Kerr Manufacturing, Romulus, MI, USA), with a light output of 550 mW/cm2. In Class II restorations, the adhesive system and the first increment of resin composite were applied to guarantee a better cure of the composite in the gingival margin prior to placing the pre-contoured metal matrices and wood wedges for proximal occlusal restorations (Table 3). A post-occlusal adjustment was performed with carbon paper and fine-grit diamond burs, and the caries, post-operative sensitivity, quality of the interproximal contact and cervical adaptation was checked by means of dental floss and inter-proximal radiographs. Finishing and polishing were carried out after 1 week, using fine-grit diamond burs (KG Sorensen, Barueri, São Paulo, Brazil) and aluminum oxide polishing paste (Kerr Manufacturing) in rubber cups on the occlusal surfaces. When necessary, abrasive strips (3M ESPE) were used in the interproximal surface.
All restorations were evaluated after 1 week (baseline) and 12 months for the following characteristics: retention, color match, interfacial staining, secondary anatomical form, marginal adaptation or integrity and surface texture (Leinfelder, 1987). The restorations were clinically evaluated by 2 investigators (NRR and ADL) using the modified USPHS criteria as first described by Cvar and Ryge (1971) and adapted by Wilson and others (2002) (Table 4). Each examiner evaluated the restoration once and, independently, they were unaware of which material had been used, creating a double-blind study.
When disagreements arose during evaluations, the examiners had to reach a consensus. Descriptive statistics were used to describe the frequency distributions of the evaluated criteria. Friedman repeated measures analysis of variance by rank and Wilcoxon sign-ranked test for pair-wise comparisons (α=0.05) were used for data analysis. The differences in the ratings by the 2 operators after 12 months were tested with Fisher's exact test (α=0.05) (Siegel, 1996). As a measurement of agreement between the examiners, Cohen's Kappa statistic was used.
RESULTS
The results are summarized in the Tables 5 and 6. In total, 148 restorations were placed in 37 patients. The distribution of the restorations was nearly similar between Class I (81) and Class II (67) cavities. Sixty-nine percent of the restorations were placed in molars (102) and 31% were placed in premolars (46). All patients attended the 1-year recall.
The Cohen's Kappa statistics (0.87) showed strong agreement between the examiners and no statistical difference was observed in their answers (p=0.76). At baseline, post-operative sensitivity was observed in 7 restorations, which disappeared in the 12-month evaluation. No secondary caries, marginal discoloration or lack of retention was observed after 1 year.
Color match and marginal adaptation were the items that received the highest number of Bravo scores (11 and 12, respectively, Figures 1 and 2). Only 4 restorations were classified as Bravo in anatomic form. Six restorations showed poor surface texture after 12 months (Figures 1 through 3). No statistical difference was observed between materials (p>0.05) and their performance at the baseline and after 1 year was statistically similar (p>0.05).
Upper left first molar restored with One Step Plus adhesive system plus Pyramid resin after 1 year. Note the small fracture at the distal margin. The restoration was classified as Bravo in the item color mismatch, marginal dis-adaptation and surface texture.
Upper left first molar restored with One Step Plus adhesive system plus Pyramid resin after 1 year. Note the small fracture at the distal margin. The restoration was classified as Bravo in the item color mismatch, marginal dis-adaptation and surface texture.
Lower left first molar restored with Excite plus Tetric Ceram after 1 year. The surface texture and color mismatch of the restoration were classified as Bravo.
Lower left first molar restored with Excite plus Tetric Ceram after 1 year. The surface texture and color mismatch of the restoration were classified as Bravo.
DISCUSSION
Evaluation of the composites depicted minor changes compared to the baseline. This fact is not surprising, since several studies have already shown a satisfactory performance of microhybrid composites in posterior teeth during initial periods of evaluation (Leinfelder, 1995; Abdalla & Alhadainy, 1996; Schoch & others, 1999; Perdigão & others, 2003).
Two microhybrid composites were evaluated in this study. Long-term clinical reports demonstrated good clinical performance of Tetric Ceram in posterior teeth, as well as its predecessor, Tetric resin composite (Wilson & others, 2000; Busato & others, 2001; Schäfers & Krantz-Schafers, 2003; Manhart & others, 2004). Although there is no long-term report on the performance of the other microhybrid composite that was evaluated (Esthet-X), short-term studies have indicated that this resin composite seems to have a promising performance in posterior teeth (Dunn & others, 2002; Perdigão & others, 2003; Türkün, 2005).
Packable resin composites arose from the progressive development of composite materials for posterior teeth. However, the packable composites available on the market have different features, mainly in the distribution and size of inorganic particles. This fact causes profound differences in the mechanical and physical properties of these composites and, therefore, their performance is material-dependent (Leinfelder & others, 1999; Ferracane & others, 1999; Choi & others, 2000; Abe & others, 2001; Abe & others, 2005).
To the extent of the authors' knowledge, no clinical study has attempted to evaluate Pyramid resin. The inorganic phase of Pyramid resin is very similar to Surefil composite (Abe & others, 2001; Sabbagh & others, 2004); therefore, some properties related to the inorganic matrix, such as surface texture characteristics (Ryba & others, 2002) and mechanical properties, are very similar to Surefil composite (Ferracane & others, 1999; Choi & others, 2000; Abe & others, 2001; Abe & others, 2005). Although no statistical difference was observed between Pyramid and the other composites, in the surface texture item, this material had more Bravo scores after 12 months. It is likely that this is due to the higher mean particle size of this material. Materials with higher particle size, around 15 μm, tend to have lower performance in surface texture compared to materials with a mean particle size inferior to 1 μm (Loguercio & others, 2001; Yip & others, 2003; Türkün & Aktener, 2001), such as Tetric Ceram, Esthet-X and Filtek Supreme.
Irrespective of the above concerns, the packable composite Pyramid showed good performance after 1 year, which was similar to the microhybrid resins Esthet-X and Tetric Ceram (Perry & Kugel, 2000; Loguercio & others, 2001; Türkün & Aktener, 2001; Yip & others, 2003). Unfortunately, this composite was discontinued from the market and was substituted by Aelite LS packable (BISCO).
Nanofilled composites were recently released onto the market (Mitra & others, 2003). Nanotechnology is the production of functional materials and structures in the range of 0.1 to 100 nanometers by various physical and chemical methods (Mitra & others, 2003). Based on this concept, only Filtek Supreme manufacturing is based on nanotechnology composite. Other manufacturers have released some products, claiming that they are nanofilled composites. However, these new composites (Grandio [Voco], Premise [Kerr Dental], Símile [Jeneric/Pentron] and Aelite Esthetic Enamel [BISCO]) have maintained glass particles with a 1-mm mean size and have included some nano-particulated silica (Baseren, 2004). According to Farah and Powers (2003), the materials that combined glass particles, silica coloidal and nano-sized particles should be named nanohybrid composites, not nanofilled composites.
Laboratory investigations have demonstrated that Filtek Supreme can offer high translucency and high polish similar to microfilled composites, depending on the polish system (Baresen, 2004; Yap & others, 2004a; Turssi, Ferracane & Serra, 2005), while maintaining physical properties and wear equivalent to several hybrid composites (Mitra & others, 2003; Felten & others, 2003; Lu & others, 2005). Gloss and surface texture are maintained after in vitro aging (Yap & others, 2004b; Heintze & Forjanic, 2005; Chapman, Burgess & Mercante, 2005).
In this investigation, Filtek Supreme showed good performance in posterior teeth, which was similar to the other microhybrid and packable composites evaluated. Other clinical studies, however, have not reached similar conclusions. For example, Ernst and others (2005) compared the clinical performance of Filtek Supreme (3M ESPE) and Tetric Ceram (Vivadent) in posterior teeth after 12- and 24-months and observed that both materials were similar in all items except color match. According to the authors, Tetric Ceram had a higher percentage of color mismatch after 12 and 24 months than Filtek Supreme. In another study, Bharadwaj and others (2005) evaluated, in vivo, the wear of Filtek-Supreme compared with Z100 (3M-ESPE) and human enamel. The results showed that, after 1 year of clinical service, the polish of Z100 was significantly worse than Filtek Supreme, although no difference was observed between the materials in regard to wear, which was similar to human enamel.
Unfortunately, as the above studies are abstract, it is difficult to deeply analyze the experimental design and inherent variables of the studies, which could affect reliability of the data.
In regard to postoperative sensitivity or interface discoloration, a minor occurrence was found after 1 year. This finding must be related to the excellent performance of the 2-step etch&rinse adhesive system employed, as already demonstrated in other clinical investigations (Loguercio & others, 2001; Perdigão & others, 2003 ,Perdigão & others, 2004).
Other short-term and long-term clinical studies of nanofilled resin composites are important for predicting the longevity of materials. It is also necessary to emphasize that the timeframe for this study was not of such duration to indicate the long-term suitability of the tested materials, but it may provide an indication regarding their future performance.
CONCLUSIONS
It seems reasonable to conclude that, based on the results obtained in this study, nanofilled Filtek Supreme, the packable composite Pyramid and the 2 microhybrid composites Esthet-X and Tetric Ceram exhibited excellent clinical performance after 1 year.
Lower right first molar restored with Prime & Bond NT and Esthet-X after 1 year. The restoration was classified as Bravo for surface texture.
Lower right first molar restored with Prime & Bond NT and Esthet-X after 1 year. The restoration was classified as Bravo for surface texture.
Lower right second molar restored with Single Bond and Filtek Supreme after 1 year. The excellent surface texture and color match can be seen.
Lower right second molar restored with Single Bond and Filtek Supreme after 1 year. The excellent surface texture and color match can be seen.
Acknowledgments
This investigation was supported in part by PIBIC/CNPq/UNOESC/Joaçaba/SC and CNPq Grants (551049/2002-2; 350085/2003-0; 302552/2003-0 and 474225/2003-8). The materials Filtek Supreme and Esthet-X were donated by the manufacturers (3M ESPE, Campinas, Brazil and Caulk-Dentsply, Rio de Janeiro, Brazil).