After calibration of the restoration procedure, three operators experienced differences in tooth-composite interface morphology and microleakage formation. These differences reflect technique-sensitivity of the etch-and-rinse adhesive. The lowest microleakage on dentin was related to an enhanced interface integrity. After additional application of an adhesive component, sealing of the enamel and dentin was partially enhanced, but microleakage formation did not decrease. These results are helpful in the comparative evaluation of other bonding systems.

The aim of this in vitro study was a comparative investigation of tooth-composite interface morphology and microleakage formation after the calibrated restoration of Class II cavities with a proven multi-component, three-step, total-etch adhesive system by three experienced operators. The current study also aimed to acquire data about the well-tried adhesive system under defined laboratory conditions for further comparative assessments with other adhesives.

Forty Class II cavities were prepared on extracted, caries-free molars. In the first study (Part A), 24 cavities were restored (n=8 each) according to the manufacturers' instructions.

In the second study (Part B), 16 teeth (n=6, 4, 6) were filled in the same way; however, the last component of the same adhesive system was applied twice. The teeth were prepared for microleakage testing and morphological assessment of the composite-tooth interface by scanning electron microscopy. The three operators had differences with regard to adhesive layer formation, inter-/peritubular adhesive penetration and the formation of adhesive failures on the dentin interface and microleakage on dentin. The lowest microleakage on dentin was related to enhanced peritubular and intertubular adhesive penetration.

After double application of an adhesive component (Part B), the sealing of the enamel and dentin with adhesive increased partially, and adhesive failures on dentin were partly diminished, but no distinct effects on microleakage formation were found.

The results confirm the technique-sensitivity of the etch-and-rinse adhesive related to interface morphology and microleakage formation. These results are helpful in the comparative evaluation of other bonding systems.

A main topic in the field of tooth-colored adhesive restoration of cavities is the experimental and clinical comparative assessment of restorative systems. Because of differences in thermal expansion of the restoration and tooth, stress resulting from polymerization shrinkage of the composite and numerous other physical and chemical loadings on the restoration during its intraoral exposure, gaps may develop along the interface tooth-restoration, resulting in microleakage formation, pulpal irritation, secondary caries and restoration failure.1 Since it takes several years to produce evidence of clinical assessments of restoration systems,2 experimental studies are indispensable for estimating their clinical potential. Although there is no accepted experimental mode for the early experimental assessment of restorative systems, and clinical trials still remain the ultimate test,3–4 experimental in vitro/in vivo bond testing may predict the results of clinical studies to a certain degree.1,4–5 Between bond strength measurements on enamel and dentin6–8 and studies related to the biocompatibility of system components9–11 and spectroscopic investigations,12–13 numerous imaging methods can help to characterize restoration systems in great detail by investigating phenomena, such as marginal integrity, microleakage and the mechanisms of mechanical adhesion (interlocking/hybridization of enamel and dentin).14 Such experimental screenings include investigating tooth substrates of different qualities (sound/carious dentin)8,15–19 and C-factors,20–22 simulation of pulpal pressure and the oral environment,23–25 the application of thermal and occlusal stresses, fatigue simulation26–27 or, for better simulation of the clinical situation, studies on in vivo restored teeth that have been in use for a certain period of time.5,9,25,28–33 

In the past, one of the intentions of the authors of the current study was to combine the clinical assessment of enamel-dentin bonding systems with experimental in vivo and in vitro studies on the basis of the micromorphological evaluation of the tooth-composite interface and microleakage formation.2,5,24,29,34–38 This kind of experimental proof is, however, aimed at the comparative assessment of restoration systems that are investigated using the same laboratory standard, analogous to the rating of adhesive systems on the basis of bond strength values achieved within a single standardized trial.

It is widely accepted that enamel-dentin bonding is based on micromechanical retention between resin and the demineralized and primed surfaces of enamel and dentin. Good resin penetration and sufficient resin polymerization are necessary, but many factors can impair this.1,4,39–42 In addition to the material-specific parameters and equipment used, the variability in handling by the clinical operators plays an important role.1,6,43–48 Etch-and-rinse adhesives are considered to be partially technique-sensitive.1 To overcome these challenges, simplified and user-friendly self-etch adhesives have been developed.1,4,27,33,49–51 

The aim of the current study was the experimental investigation of operator (technique) sensitivity of a three-step total-etch adhesive after calibration of the restoration procedure for all operators under the conditions of a dental school. The null hypothesis was that there is no significant difference with regard to interface morphology and microleakage formation when three longstanding clinicians with experience in experimental and clinical trials perform Class II composite restorations with a well-proven multi-component total-etch adhesive system in combination with the assigned fine-particle hybrid resin composite. The current study further aimed to determine a set of base values for the microleakage and morphological assessment of interface patterns for comparative evaluations of other bonding systems under calibrated conditions for tooth-colored adhesive restorations and the introduced laboratory standard for specimen preparation and evaluation.

Samples, Cavity Preparation and Restoration

Forty caries- and defect-free extracted human molars stored for up to one month in 0.1 % aqueous solution of thymol at 4°C were used.

The teeth were randomly assigned to three longstanding practicing clinicians (n=14, 12, 14). All of the operators had experience in clinical and experimental trials. Before starting the study, the restoration procedure was calibrated for all operators, once more relating to cavity preparation and every step of the restoration process, especially regarding dentin wetness and moisture removal as well as gentle drying of the adhesive components (see Table 1). Mesio-occlusal Class II cavities with cervical margins below the cement-enamel junction were prepared and smoothed with diamond burs at high speed under copious water-cooling (gingival step within dentin/cement; depth 2–2.5 mm; 80 μm diamond burs, #8223, APS, Intensiv SA, Grancia, Switzerland). All the margins were finished to a 90° angle (no bevels). After finishing (25 μm diamond burs, #3223, APS), the cavities were carefully cleaned with water and dried. The preparation of the cavity was followed immediately by the restorative procedures.

Table 1

Materials for Restoration, Batch Numbers and Instructions for Application of Materials

Materials for Restoration, Batch Numbers and Instructions for Application of Materials
Materials for Restoration, Batch Numbers and Instructions for Application of Materials

The prepared cavities were etched with phosphoric acid (37%, acid gel, Total Etch, Ivoclar Vivadent AG, Schaan, Liechtenstein), rinsed for 15 seconds with water, then briefly and gently dried with compressed air until the liquid film began to disappear (moist bonding).

In Part A (n=8 each), application of the adhesive Syntac Classic (Ivoclar Vivadent AG) was carried out according to the manufacturers' instructions (Table 1). After analyzing the results, the adhesive component Heliobond was applied twice (Part B, n=6, 4, 6; Table 1).

Subsequently, the cavities were filled with composite Tetric Ceram (Ivoclar Vivadent AG) and the restorations were contoured and finished with diamond burs (#4274, 15 μm, Composhape A & P, Intensive SA; Greenie, Shofu Inc, Ratingen, Germany).

The curing light (Astralis 10, Ivoclar Vivadent) was checked with a curing radiometer (Demetron Model 100, Demetron Research Corp, Danbury, CT, USA) before starting the study (output intensities, see Table 1). All three operators used the same curing light on all of the specimens (for curing procedures and output intensities see Table 1).

Specimen Preparation, Microleakage and SEM Investigation

The roots of the teeth were removed at least 2 mm below the cervical margin of the restoration (80 μm diamond bur, APS, Intensiv SA) and the teeth were stored in Aqua bi-destillata (37°C, 24 hours) and immersion-fixed in buffered glutaraldehyde (5%, 4°C) for 24 hours.

For assessment of the microleakage, the teeth were soaked in fresh buffer three times (one hour each; 0.1 M sodium phosphate buffer, pH 7.2), and the surfaces were covered with nail varnish except for a 1 mm window around the restorations. The samples were then immersed in basic ammoniacal silver nitrate (AgNO3/NH4OH, 3 mol/L, pH 9.5) for 24 hours at 37°C in darkness before rinsing again with distilled water for 60 seconds. The samples were then exposed to a photo-developing solution (Neotenal Liquid, Tetenal Photowerk GmbH & Co KG, Norderstedt, Germany) under fluorescent light (8 hours; 20°C; UV-Hand lamp N8 11102L, K Benda Laborgeräte, Wiesloch, Germany) and rinsed again with distilled water for 60 seconds. The teeth were embedded in Stycast 1266 (Emerson & Cuming, Westerlo, Belgium), mounted on plastic blocks and longitudinally sectioned (n=3 each; 200 μm thickness; Leitz 1600 Sägemikrotom, Ernst Leitz Wetzlar GmbH, Wetzlar, Germany). At the sections, the microleakage was then examined with a stereomicroscope (magnification 25× to 40×; Citoval 2, VEB Carl Zeiss, Jena, Germany; digital microscope camera DMC 2, Polaroid, Offenbach, Germany with accessory operation and control software for PC; Adobe Photoshop, Adobe Systems Inc, San José, CA, USA).

The samples were decalcified with 2% HCl for 10 seconds, deproteinized with 10% sodium hypochlorite for 60 seconds and rinsed with distilled water, after which they were dehydrated in an ascending series of ethanol baths (30% to 100%), immersed in Hexamethyldisilazan for 10 minutes (HMDS, Carl Roth GmbH + Co, Karlsruhe, Germany) and air dried.

All the samples were mounted on metal stubs (Leit-C nach Göcke, Neubauer Chemikalien, Münster, Germany; sample holder G 400, Plano GmbH, Wetzlar, Germany); they were sputter coated with gold (20 nm, Edwards Sputter Coater S 150B, BOC Edwards Ltd, Crawley, Great Britain) and examined with a scanning electron microscope (SEM, CamScan CS 24, Cambridge Scanning Comp Ltd, Cambridge, Great Britain) in the backscattered and secondary electron mode at 20 kV accelerating voltage.

Assessment Criteria

The interface morphology was characterized by:

  • - adhesive layer formation (percentage occurrence on enamel/dentin-composite interface),

  • - intertubular resin penetration (mean thickness ± standard deviation of the hybrid layer, presence of areas of incomplete intertubular resin penetration),

  • - peritubular resin penetration (maximum depth) and lateral resin penetration,

  • - tag formation on enamel and dentin (yes/no, maximum length),

  • - gap formation between restorative material, adhesive layer, hybrid layer and enamel/dentin, and

  • - occurrence of crumbly composite on the dentin interface.

The microleakage was measured in terms of the length of AgNO3-penetration and was indicated as the percentage of the length of the enamel/dentin-composite interface.

Evaluation of Data

Statistics

The differences between operators/parts with regard to adhesive layer formation, hybrid layer thickness, peritubular and incomplete intertubular resin penetration, microleakage and the formation of total adhesive failures on the interface were analyzed using the Kruskal-Wallis test and the two-tailed U-test by Mann and Whitney (α=0.05, Bonferroni adjustment, SPSS 14.0 for Windows, SPSS Inc, Chicago, IL, USA).

Significance levels, which resulted from the Bonferroni adjustment, were 0.0071 and 0.0166, respectively. When p-values were above the significance levels but smaller than 0.07, it was recommended that the difference be assessed as tendential.

Ranking of Operators (interface morphology, microleakage and total adhesive failures)

The mean values of parameters measured for each operator regarding adhesive layer formation, hybrid layer thickness, incomplete intertubular resin penetration, peritubular/lateral adhesive penetration and tag formation on enamel and dentin were ranked with grades 1, 2 and 3. Grade 1 corresponded to the most favorable of the three values, grade 3 to the most unfavorable.

For each operator, a mean rank was calculated, which was related to the mean rank of the assigned microleakage (enamel and dentin).

Each of the three sections per tooth was assessed with a 1 or 0 (total adhesive failure on enamel/dentin: yes/no) and a rank for each tooth. The total number of ranks per operator was determined.

Tables 2 and 3 present the results of the investigation. On enamel and dentin, microleakage was generally verifiable (Figure 1). In both parts of the study, all three operators verified the typical interaction pattern on the tooth-composite interface. The adhesive layers were generally incompletely formed (Figures 2 and 3). The hybrid layers varied in thickness between 3.7 μm and 5.3 μm; however, in 17%–66% of the images, these layers were partially incomplete (Figure 4). Distinct adhesive tags arose on enamel and dentin. On dentin, these were peritubularly anchored and laterally branched (Figure 3). Adhesive failures occurred on sites with and without a detectable adhesive layer; in the former case, they occurred mostly between the adhesive and hybrid layer (Figures 5 and 2a).

Figure 1

Light microscopic images of tooth cross-sections after the restoration of Class II cavities with Syntac Classic–Tetric Ceram.

Figure 1A: No microleakage formation on enamel (e) and dentin (d); Figure 1B: Microleakage (ml) as Ag-labeling on enamel and dentin; insertion shows silver particles (Ag) within the gap on a dentin interface (SEM, c: resin composite, a: adhesive layer, h: hybrid layer, t: adhesive tag).

Figure 1

Light microscopic images of tooth cross-sections after the restoration of Class II cavities with Syntac Classic–Tetric Ceram.

Figure 1A: No microleakage formation on enamel (e) and dentin (d); Figure 1B: Microleakage (ml) as Ag-labeling on enamel and dentin; insertion shows silver particles (Ag) within the gap on a dentin interface (SEM, c: resin composite, a: adhesive layer, h: hybrid layer, t: adhesive tag).

Close modal
Figure 2

Scanning electron microscopic images (SEM) of the composite-enamel/dentin interface.

Figure 2A: Part A, incompletely formed adhesive layer (a); adhesive failure (af) on dentin interface without adhesive layer; cohesive defects (cf) in composite (c), enamel (e) and dentin (d); gap between enamel and dentin; compound on enamel. Figure 2B: Part B, incompletely formed adhesive layer; cohesive failure on dentin interface at site of an adhesive layer; compound on enamel and dentin.

Figure 2

Scanning electron microscopic images (SEM) of the composite-enamel/dentin interface.

Figure 2A: Part A, incompletely formed adhesive layer (a); adhesive failure (af) on dentin interface without adhesive layer; cohesive defects (cf) in composite (c), enamel (e) and dentin (d); gap between enamel and dentin; compound on enamel. Figure 2B: Part B, incompletely formed adhesive layer; cohesive failure on dentin interface at site of an adhesive layer; compound on enamel and dentin.

Close modal
Figure 3

SEM images of interfaces (A) on dentin with resin composite (c), adhesive layer (a), hybrid layer (h), distinct adhesive tags (t), peritubular resin penetration (p) and lateral branches (l) and (B) on enamel (e) with adhesive layer and resin tags.

Figure 3

SEM images of interfaces (A) on dentin with resin composite (c), adhesive layer (a), hybrid layer (h), distinct adhesive tags (t), peritubular resin penetration (p) and lateral branches (l) and (B) on enamel (e) with adhesive layer and resin tags.

Close modal
Figure 4

SEM images of dentin interfaces with incomplete intertubular resin penetration. Figure 4A: hybridoid zone (hz); Figure 4B: silver particle (Ag) within porous area (c: resin composite, h: hybrid layer, t: adhesive tag, l: lateral branches, d: dentin).

Figure 4

SEM images of dentin interfaces with incomplete intertubular resin penetration. Figure 4A: hybridoid zone (hz); Figure 4B: silver particle (Ag) within porous area (c: resin composite, h: hybrid layer, t: adhesive tag, l: lateral branches, d: dentin).

Close modal
Figure 5

SEM images of dentin interfaces with adhesive failures (af) on sites with (Figure 5A) and without (Figure 5B) a detectable adhesive layer (a), (A) silver particles (Ag) within the gap, (B) adhesive failure occurs with disappearing adhesive layer (c: resin composite, h: hybrid layer, t: adhesive tag, l: lateral branches, d: dentin).

Figure 5

SEM images of dentin interfaces with adhesive failures (af) on sites with (Figure 5A) and without (Figure 5B) a detectable adhesive layer (a), (A) silver particles (Ag) within the gap, (B) adhesive failure occurs with disappearing adhesive layer (c: resin composite, h: hybrid layer, t: adhesive tag, l: lateral branches, d: dentin).

Close modal
Table 2

Characteristics of Tooth-composite Interface and Microleakage for Three Operators and Parts A and B

Characteristics of Tooth-composite Interface and Microleakage for Three Operators and Parts A and B
Characteristics of Tooth-composite Interface and Microleakage for Three Operators and Parts A and B
Table 3

Total Adhesive Failures on Tooth-composite Interface in Parts A and B

Total Adhesive Failures on Tooth-composite Interface in Parts A and B
Total Adhesive Failures on Tooth-composite Interface in Parts A and B

In the main, enamel bonding was favored, as was indicated by generally lower microleakage and cleft formation (Tables 2 and 3). In areas on dentin where no adhesive layer was detectable, the composite appeared to be partially crumbling (Figure 6).

Figure 6.

SEM image of a dentin interface, no detectable adhesive layer, composite (c) is crumbling (h: hybrid layer, t: adhesive tag, d: dentin).

Figure 6.

SEM image of a dentin interface, no detectable adhesive layer, composite (c) is crumbling (h: hybrid layer, t: adhesive tag, d: dentin).

Close modal

Part A

There were no significant differences among operators with regard to microleakage formation. This also held true for operators 2 and 3 with regard to all the other parameters.

For operator 1, compared with operators 2 and 3, adhesive layer formations on enamel and dentin were significantly diminished or showed a tendency regarding this, but the dentin was regularly more conspicuous and more distinctly hybridized (Figure 3). Therefore, in these specimens, incomplete intertubular resin penetration was reduced and the peritubular adhesive penetration was enhanced. In addition, a significantly thicker hybrid layer was obtained compared with operator 3, as well as in the tendency-diminished number of total adhesive failures on the dentin interface compared with operator 2.

The mean ranks of operators 1, 2 and 3, resulting from criteria characterizing interface morphology, were 1.40, 2.20 and 2.00, respectively. The mean ranks relating to microleakage formation on enamel and dentin were 1.50, 2.50 and 2.00, respectively, relating to medians of microleakage 1.0, 2.5 and 2.5.

Part B

After a double application of Heliobond, the sealing of enamel and dentin with adhesive was significantly enhanced in 3/6 cases (operators 1 and 2). For operator 1, the incomplete intertubular monomer penetration was diminished, and with operators 2 and 3, the peritubular adhesive penetration was enhanced (tendency). For operator 1, the microleakage on enamel was increased, but total adhesive failures on the dentin interface were avoided.

There were differences (significance and tendency) among all operators regarding most of the parameters assessed. The adhesive layer formation on enamel/dentin was increased with operator 2, compared with operators 1 and 3. For operator 1, compared with operators 2 and 3, the intertubular resin penetration (thickness of the hybrid layer, intertubular resin penetration) was raised, and the microleakage formation on dentin and the number of total adhesive failures on the dentin interface were reduced.

The mean ranks of operators 1, 2 and 3 regarding the criteria of interface morphology were 1.65, 1.80 and 2.15, respectively. With regard to microleakage on enamel and dentin, all the operators had the same rank of 2.00 for both means and medians.

The concept of tooth-colored adhesive restorations with etch-and-rinse, as well as self-etch adhesives, is based on the working steps of the “conditioning” of enamel/dentin, the “priming” of their surfaces and “resin application.” Currently, there are a wide variety of adhesive systems available on the market. As older, multiple-step total-etch systems are considered technique-sensitive, adhesives have been developed as far as one-step, self-etch systems, simplifying handling by integrating several steps together. As a result, these systems are more user-friendly. However, in clinical and experimental studies on the application of simplified one-step self-etch systems, no advance can be seen compared with earlier multi-step total-etch adhesives.4,7,26–27,50,52–55 On the contrary, diminished bonding effectiveness was noted in these systems, along with shortcomings in interface integrity.17,50 However, a simple, user-friendly system is only acceptable if it functions and, thus, clinical effectiveness is of essential importance, along with technique sensitivity. On the basis of data from published clinical trials, Peumans and others4 observed inefficient clinical performance in one-step self-etch systems when compared with three-step etchand-rinse, two-step etch-and-rinse and two-step self-etch adhesives; whereby, three-step systems were shown to perform best. Akimoto and others51 and Peumans and others56 presented “excellent” clinical data for a two-step self-etch adhesive after 5- or 10-year placement. Also, in laboratory tests, “older” materials performed better than simplified adhesives.27,50,57 The clinical data and results from experimental investigations of the interface morphology and microleakage formation for systems of different functionalities from other self-studies also confirm this.2,5,34–38 Peumans and others4 emphasized the simultaneously observed superior laboratory and clinical performance of three-step etch-and-rinse adhesives. These authors concluded that this probably resulted from good enamel/dentin interlocking/hybridization on the tooth-composite interface. Therefore, it is worth considering the interface morphology of these products as a basis for the comparative assessment of recently developed systems.50 

In the current study, Syntac Classic was used in the functionality “multi-component” as a three-step etch-and-rinse adhesive (Part A). It was also used with a double application of the adhesive Heliobond (Part B) as the layer forming part (light-curing) of the Syntac System to produce thicker resin layers and reduce the number of adhesive failures within the interface.41,53 It is a widespread system and is used in the clinic of the authors of the current study in combination with the composite Tetric Ceram.58–60 Thus, it was selected as a basic material for the comparative experimental proof of other adhesive systems.59 

It is notable that, on dentin, the (significant/insignificant) lowest amount of microleakage and total adhesive failures (operator 1; Parts A, B) corresponded with the most intensive adhesive interlocking by tag formation, lateral branches and a high-grade inter- and peritubular monomer penetration, although there was no corresponding tendency toward the sealing of dentin with adhesive. This result corresponded to the broader differences among the operators with regard to interface morphology vs microleakage in Part A and the occurrence of generally enhanced cleft formation on the dentin interface in cases of operators 2 and 3. However, the reduced number of total adhesive failures on dentin in Part B also agreed with the increased adhesive layer formation in this part. Adhesive failures along the interface on enamel and dentin generally reflect sites of insufficient bonding, independent of causal forces, such as polymerization shrinkage or forces that act during specimen preparation, sputtering and imaging with a high-energy electron beam within the vacuum in the column of an electron microscope. Such a cleft generally demonstrates the site of the weakest compound on a distinct spot within the specimen.5,61 If the interface withstands all loadings, either a fully preserved specimen or cohesive defects within the section can be observed.

The distinct differences found among the operators regarding the criteria of interface morphology support results from other laboratory investigations1 and demonstrate a certain technique sensitivity of Syntac Classic. Many studies have dealt with the question of which factors make multistep adhesives more technique-sensitive and, thus, can influence the enamel/dentin bond.1,4,6 Working-steps, such as the etching of enamel and dentin, the drying of cavities, the application of single adhesive system components and composites clearly permit even experienced clinicians enough free reign in handling. Although after the double application of Heliobond (Part B) the operators were ranked equal in microleakage, the variations between them regarding interface morphology continued. Thus, a certain “standardization” between the operators was not achieved.

When comparing Part B with Part A, the sealing of enamel and dentin and the hybridization of dentin regarding peri- and intertubular monomer penetration was increased in three of six or two of six comparisons (Table 2).

Microleakage was not reduced. However, with regard to the significantly/insignificantly decreased number of total adhesive failures on the dentin interface, the more frequently appearing adhesive layer could possibly have acted as an elastic buffer zone between composite and enamel/dentin, especially in the case of operator 1, by whom the adhesive failures on dentin were completely avoided. In this context, the reasons for the regularly found composite crumbling on the dentin interface are a matter of speculation. At these sites, an adhesive layer was never detected and, thus, the postulated elastic buffer zone was also not present. Therefore, whenever the composite-dentin compound was strong enough, acting forces could also have led to cohesive defects within the composite.

The data in this in vitro study provide a basis for further comparative experimental assessments of other systems under standardized clinical and laboratory conditions considering the observed technique sensitivity of Syntac Classic.

  1. The null hypothesis must be rejected, as there were differences between longstanding “calibrated” clinicians with regard to interface morphology and microleakage formation.

  2. The double application of the component Heliobond from the Syntac System resulted in partially increased sealing of enamel and dentin and in the partial reduction in adhesive failures along the dentin interface; however, it did not lead to a diminished microleakage formation under the conditions of the current study.

The authors thank Mrs Claudia Rüger for her professional technical assistance, PD Dr E Schuster (IMISE, University of Leipzig, Leipzig, Germany) for the statistical consultations and Timothy Jones (IALT, University of Leipzig) and Iain Hewitt (Newcastle, Great Britain) for critical revision of the manuscript.

1
Jacobsen
,
T.
,
K. J.
Söderholm
,
M.
Yang
, and
T. F.
Watson
.
2003
.
Effect of composition and complexity of dentin-bonding agents on operator variability-analysis of gap formation using confocal microscopy.
European Journal of Oral Sciences
111
6
:
523
528
.
2
Merte
,
I.
,
H.
Schneider
, and
K.
Merte
.
2004
.
Is it necessary to assess experimentally and clinically restorative materials already on the market? [Ist es notwendig, eingeführte Füllungsmaterialien klinisch-experimentell zu bewerten?].
Schweizer Monatsschrift für Zahnmedizin
114
11
:
1124
1131
. (
article in German
).
3
Sudsangiam
,
S.
and
R.
van Noort
.
1999
.
Do dentin bond strength tests serve a useful purpose?
The Journal of Adhesive Dentistry
1
1
:
57
67
.
4
Peumans
,
M.
,
P.
Kanumilli
,
J.
De Munck
,
K.
Van Landuyt
,
P.
Lambrechts
, and
B.
Van Meerbeek
.
2005
.
Clinical effectiveness of contemporary adhesives: A systematic review of current clinical trials.
Dental Materials
21
9
:
864
881
.
5
Schneider
,
H.
,
M.
Fröhlich
,
G.
Erler
,
C.
Engelke
, and
K.
Merte
.
2000
.
Interaction patterns between dentin and adhesive on prepared Class V cavities in vitro and in vivo.
Journal of Biomedical Materials Research
53
1
:
86
92
.
6
Frankenberger
,
R.
,
N.
Kramer
, and
A.
Petschelt
.
2000
.
Technique sensitivity of dentin bonding: Effect of application mistakes on bond strength and marginal adaptation.
Operative Dentistry
25
4
:
324
330
.
7
Frankenberger
,
R.
,
J.
Perdigão
,
B. T.
Rosa
, and
M.
Lopes
.
2001
.
“No-bottle” vs “multi-bottle” dentin adhesives–a microtensile bond strength and morphological study.
Dental Materials
17
5
:
373
380
.
8
Erhardt
,
M. C.
,
J. A.
Rodrigues
,
T. A.
Valentino
,
A. V.
Ritter
, and
L. A.
Pimenta
.
2008
.
In vitro microTBS of one-bottle adhesive systems: Sound versus artificially-created caries-affected dentin.
Journal of Biomedical Materials Research, Part B, Applied Biomaterials
86
1
:
181
187
.
9
Teixeira
,
H. M.
,
A. B.
Do Nascimento
,
J.
Hebling
, and
C. A.
De Souza Costa
.
2006
.
In vivo evaluation of the biocompatibility of three current bonding agents.
Journal of Oral Rehabilitation
33
7
:
542
550
.
10
Busch
,
M.
,
B.
Benedix
,
T.
Herrmann
,
H.
Schneider
, and
K.
Merte
.
2005
.
[“Etch-and-Rinse-Adhesive” Pulpaschutz und Bondingeffektivität eines 2-Schritt-Systems].
Deutsche Zahnärztliche Zeitschrift
Supplement
:
(DGZMK 2005) Abstract #263 p
.
A-82
A-83
.
11
Lu
,
Y.
,
T.
Liu
,
X.
Li
,
H.
Li
, and
G.
Pi
.
2006
.
Histologic evaluation of direct pulp capping with a self-etching adhesive and calcium hydroxide in beagles.
Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics
102
4
:
e78
84
. (
published online
).
12
Zou
,
Y.
,
S. R.
Armstrong
, and
J. L.
Jessop
.
2008
.
Apparent conversion of adhesive resin in the hybrid layer, Part 1: Identification of an internal reference for Raman spectroscopy and the effects of water storage.
Journal of Biomedical Materials Research, Part A
86
4
:
883
891
.
13
Sword
,
J.
,
D. H.
Pashley
,
S.
Foulger
,
F. R.
Tay
, and
R.
Rodgers
.
2008
.
Use of electrochemical impedance spectroscopy to evaluate resin-dentin bonds.
Journal of Biomedical Materials Research, Part B, Applied Biomaterials
84
2
:
468
477
.
14
Van Meerbeek
,
B.
,
M.
Vargas
,
S.
Inoue
,
Y.
Yoshida
,
J.
Perdigão
,
P.
Lambrechts
, and
G.
Vanherle
.
2000
.
Microscopy investigations. Techniques, results, limitations.
American Journal of Dentistry
13
:(
Spec No
).
3D
18D
.
15
Van Meerbeek
,
B.
,
L. J.
Conn
Jr
,
E. S.
Duke
,
J. D.
Eick
,
S. J.
Robinson
, and
D.
Guerrero
.
1996
.
Correlative transmission electron microscopy examination of non-demineralized and demineralized resin-dentin interfaces formed by two dentin adhesive systems.
Journal of Dental Research
75
3
:
879
888
.
16
Toledano
,
M.
,
R.
Osorio
,
L.
Ceballos
,
M. V.
Fuentes
,
C. A.
Fernandes
,
F. R.
Tay
, and
R. M.
Carvalho
.
2003
.
Microtensile bond strength of several adhesive systems to different dentin depths.
American Journal of Dentistry
16
5
:
292
298
.
17
Omar
,
H.
,
W.
El-Badrawy
,
O.
El-Mowafy
,
O.
Atta
, and
B.
Saleem
.
2007
.
Microtensile bond strength of resin composite bonded to caries-affected dentin with three adhesives.
Operative Dentistry
32
1
:
24
30
.
18
Yoshiyama
,
M.
,
R.
Carvalho
,
H.
Sano
,
J.
Horner
,
P. D.
Brewer
, and
D. H.
Pashley
.
1995
.
Interfacial morphology and strength of bonds made to superficial versus deep dentin.
American Journal of Dentistry
8
6
:
297
302
.
19
Peris
,
A. R.
,
F. H.
Mitsui
,
M. M.
Lobo
,
A. K.
Bedran-Russo
, and
G. M.
Marchi
.
2007
.
Adhesive systems and secondary caries formation: Assessment of dentin bond strength, caries lesions depth and fluoride release.
Dental Materials
23
3
:
308
316
.
20
Yoshikawa
,
T.
,
H.
Sano
,
M. F.
Burrow
,
J.
Tagami
, and
D. H.
Pashley
.
1999
.
Effects of dentin depth and cavity configuration on bond strength.
Journal of Dental Research
78
4
:
898
905
.
21
Nikolaenko
,
S. A.
,
U.
Lohbauer
,
M.
Roggendorf
,
A.
Petschelt
,
W.
Dasch
, and
R.
Frankenberger
.
2004
.
Influence of c-factor and layering technique on microtensile bond strength to dentin.
Dental Materials
20
6
:
579
585
.
22
Belli
,
S.
,
N.
Dönmez
, and
G.
Eskitascioglu
.
2006
.
The effect of C-factor and flowable resin or fiber use at the interface on microtensile bond strength to dentin.
The Journal of Adhesive Dentistry
8
4
:
247
253
.
23
Pashley
,
D. H.
1991
.
In vitro simulations of in vivo bonding conditions.
American Journal of Dentistry
4
5
:
237
240
.
24
Pioch
,
T.
,
H. J.
Staehle
,
H.
Schneider
,
H.
Duschner
, and
C. E.
Dörfer
.
2001
.
Effect of intrapulpal pressure simulation in vitro on shear bond strengths and hybrid layer formation.
American Journal of Dentistry
14
5
:
319
323
.
25
Hebling
,
J.
,
F. L.
Castro
, and
C. A.
Costa
.
2007
.
Adhesive performance of dentin bonding agents applied in vivo and in vitro. Effect of intrapulpal pressure and dentin depth.
Journal of Biomedical Materials Research, Part B, Applied Biomaterials
83
2
:
295
303
.
26
Frankenberger
,
R.
and
F. R.
Tay
.
2005
.
Self-etch vs etch-and-rinse adhesives: Effect of thermo-mechanical fatigue loading on marginal quality of bonded resin composite restorations.
Dental Materials
21
5
:
397
412
.
27
Frankenberger
,
R.
,
W. O.
Strobel
,
N.
Kramer
,
U.
Lohbauer
,
J.
Winterscheidt
,
B.
Winterscheidt
, and
A.
Petschelt
.
2003
.
Evaluation of the fatigue behavior of the resin-dentin bond with the use of different methods.
Journal of Biomedical Materials Research, Part B, Applied Biomaterials
67
2
:
712
721
.
28
Ferrari
,
M.
,
M. C.
Cagidiaco
, and
P. N.
Mason
.
1994
.
Micromorphologic relationship between resin and dentin in Class II restorations: An in vivo and in vitro investigation by scanning electron microscopy.
Quintessence International
25
12
:
861
866
.
29
Schneider
,
H.
,
T.
Pioch
,
C.
Engelke
,
G.
Haßhoff
,
M.
Fröhlich
,
H.
Duschner
, and
K.
Merte
.
2000
.
Morphological aspects of adhesive penetration in conditioned dentin in vivo/in vitro.
Journal of Dental Research
79
:
(Spec No) Abstract #1009 p
.
270
.
30
Purk
,
J. H.
,
V.
Dusevich
,
A.
Glaros
,
P.
Spencer
, and
J. D.
Eick
.
2004
.
In vivo versus in vitro microtensile bond strength of axial versus gingival cavity preparation walls in Class II resin-based composite restorations.
Journal of the American Dental Association
135
2
:
185
193
.
31
Yuan
,
Y.
,
Y.
Shimada
,
S.
Ichinose
, and
J.
Tagami
.
2007
.
Effect of dentin depth on hybridization quality using different bonding tactics in vivo.
Journal of Dentistry
35
8
:
664
672
.
32
Purk
,
J. H.
,
V.
Dusevich
,
A.
Glaros
, and
J. D.
Eick
.
2007
.
Adhesive analysis of voids in Class II composite resin restorations at the axial and gingival cavity walls restored under in vivo versus in vitro conditions.
Dental Materials
23
7
:
871
877
.
33
Imazato
,
S.
,
F. R.
Tay
,
A. V.
Kaneshiro
,
Y.
Takahashi
, and
S.
Ebisu
.
2007
.
An in vivo evaluation of bonding ability of comprehensive antibacterial adhesive system incorporating MDPB.
Dental Materials
23
2
:
170
176
.
34
Merte
,
K.
,
M.
Fröhlich
,
M.
Häfer
,
E.
Hirsch
,
H.
Schneider
, and
M.
Winkler
.
2000
.
Two-year clinical performance of two primer adhesives on Class V restorations.
Journal of Biomedical Materials Research, Part B, Applied Biomaterials
53
1
:
93
99
.
35
Fuchß
,
A.
,
M.
Häfer
,
I.
Busch
,
S.
Rupf
,
I.
Merte
,
H.
Schneider
, and
K.
Merte
.
2005
.
[Self-etch Adhäsive-Bondingeffektivität eines 2-Schritt-Systems].
Deutsche Zahnärztliche Zeitschrift
Supplement (DGZMK 2005) Abstract #260 p
.
A-82
.
36
Häfer
,
M.
,
I.
Merte
,
I.
Busch
,
S.
Rupf
,
A.
Fuchß
,
H.
Schneider
, and
K.
Merte
.
2005
.
[Klinisch-experimentelle Bewertung eines niedriggefüllten “Etch-and Rinse-Adhesive”].
Deutsche Zahnärztliche Zeitschrift
Supplement (DGZMK 2005) Abstract #264 p
.
A-83
.
37
Schneider
,
H.
,
G.
Hasshoff
,
M.
Häfer
,
I.
Busch
,
I.
Merte
,
S.
Rupf
,
A.
Fuchß
, and
K.
Merte
.
2005
.
[Bondingbewertung eines selbstätzenden Adhäsivs vom Typ “all in one bottle”].
Deutsche Zahnärztliche Zeitschrift
Supplement (DGZMK 2005) Abstract #258 p
.
A-81
.
38
Hassßhoff
,
G.
,
H.
Schneider
, and
K.
Merte
.
2004
.
Tooth-composite interface from specific and non-specific adhesive restorative systems.
Journal of Biomedical Materials Research, Part B, Applied Biomaterials
71
1
:
38
45
.
39
Nakabayashi
,
N.
,
M.
Ashizawa
, and
M.
Nakamura
.
1992
.
Identification of a resin-dentin hybrid layer in vital human dentin created in vivo: Durable bonding to vital dentin.
Quintessence International
23
2
:
135
141
.
40
Van Meerbeek
,
B.
,
S.
Inokoshi
,
M.
Braem
,
P.
Lambrechts
, and
G.
Vanherle
.
1992
.
Morphological aspects of the resin-dentin interdiffusion zone with different dentin adhesive systems.
Journal of Dental Research
71
8
:
1530
1540
.
41
Perdigão
,
J.
,
P.
Lambrechts
,
B.
Van Meerbeek
,
M.
Braem
,
E.
Yildiz
,
T.
Yucel
, and
G.
Vanherle
.
1996
.
The interaction of adhesive systems with human dentin.
American Journal of Dentistry
9
4
:
167
173
.
42
Hannig
,
M.
,
H.
Bock
,
B.
Bott
, and
W.
Hoth-Hannig
.
2002
.
Inter-crystallite nanoretention of self-etching adhesives at enamel imaged by transmission electron microscopy.
European Journal of Oral Sciences
110
6
:
464
470
.
43
Peschke
,
A.
,
U.
Blunck
, and
J. F.
Roulet
.
2000
.
Influence of incorrect application of a water-based adhesive system on the marginal adaptation of Class V restorations.
American Journal of Dentistry
13
5
:
239
244
.
44
Miyazaki
,
M.
,
H.
Onose
, and
B. K.
Moore
.
2000
.
Effect of operator variability on dentin bond strength of two-step bonding systems.
American Journal of Dentistry
13
2
:
101
104
.
45
Chuang
,
S. F.
,
J. K.
Liu
,
C. C.
Chao
,
F. P.
Liao
, and
Y. H.
Chen
.
2001
.
Effects of flowable composite lining and operator experience on microleakage and internal voids in Class II composite restorations.
The Journal of Prosthetic Dentistry
85
2
:
177
183
.
46
Miyazaki
,
M.
,
K.
Tsubota
,
H.
Onose
, and
K.
Hinoura
.
2002
.
Influence of adhesive application duration on dentin bond strength of single-application bonding systems.
Operative Dentistry
27
3
:
278
283
.
47
Asaka
,
Y.
,
M.
Miyazaki
,
T.
Takamizawa
,
K.
Tsubota
, and
B. K.
Moore
.
2006
.
Influence of delayed placement of composites over cured adhesives on dentin bond strength of single-application self-etch systems.
Operative Dentistry
31
1
:
18
24
.
48
Chiba
,
Y.
,
K.
Yamaguchi
,
M.
Miyazaki
,
K.
Tsubota
,
T.
Takamizawa
, and
B. K.
Moore
.
2006
.
Effect of air-drying time of single-application self-etch adhesives on dentin bond strength.
Operative Dentistry
31
2
:
233
239
.
49
Ibarra
,
G.
,
M. A.
Vargas
, and
W.
Geurtsen
.
2006
.
Interfacial and surface characterization of two self-etching adhesive systems and a total-etch adhesive after bonding to ground and unground bovine enamel-a qualitative study.
Clinical Oral Investigations
10
4
:
331
341
.
50
De Munck
,
J.
,
K.
Van Landuyt
,
M.
Peumans
,
A.
Poitevin
,
P.
Lambrechts
,
M.
Braem
, and
B.
Van Meerbeek
.
2005
.
A critical review of the durability of adhesion to tooth tissue: Methods and results.
Journal of Dental Research
84
2
:
118
132
.
51
Akimoto
,
N.
,
M.
Takamizu
, and
Y.
Momoi
.
2007
.
10-year clinical evaluation of a self-etching adhesive system.
Operative Dentistry
32
1
:
3
10
.
52
Dalton Bittencourt
,
D.
,
I. G.
Ezecelevski
,
A.
Reis
,
J. W.
Van Dijken
, and
A. D.
Loguercio
.
2005
.
An 18-month evaluation of self-etch and etch & rinse adhesive in non-carious cervical lesions.
Acta Odontologica Scandinavica
63
3
:
173
178
.
53
Loguercio
,
A. D.
,
A.
Costenaro
,
A. P.
Silveira
,
N. R.
Ribeiro
,
T. R.
Rossi
, and
A.
Reis
.
2006
.
A six-month clinical study of a self-etching and an etch-and-rinse adhesive applied as recommended and after doubling the number of adhesive coats.
The Journal of Adhesive Dentistry
8
4
:
255
261
.
54
Van Landuyt
,
K. L.
,
M.
Peumans
,
J.
De Munck
,
P.
Lambrechts
, and
B.
Van Meerbeek
.
2006
.
Extension of a one-step self-etch adhesive into a multi-step adhesive.
Dental Materials
22
6
:
533
544
.
55
Türkün
,
L. S.
2005
.
The clinical performance of one- and two-step self-etching adhesive systems at one year.
Journal of the American Dental Association
136
5
:
656
664
.
56
Peumans
,
M.
,
J.
De Munck
,
K.
Van Landuyt
,
P.
Lambrechts
, and
B.
Van Meerbeek
.
2007
.
Five-year clinical effectiveness of a two-step self-etching adhesive.
The Journal of Adhesive Dentistry
9
1
:
7
10
.
57
De Munck
,
J.
,
K.
Shirai
,
Y.
Yoshida
,
S.
Inoue
,
K.
Van Landuyt
,
P.
Lambrechts
,
K.
Suzuki
,
H.
Shintani
, and
B.
Van Meerbeek
.
2006
.
Effect of water storage on the bonding effectiveness of 6 adhesives to Class I cavity dentin.
Operative Dentistry
31
4
:
456
465
.
58
Schirrmeister
,
J. F.
,
K.
Huber
,
E.
Hellwig
, and
P.
Hahn
.
2006
.
Two-year evaluation of a new nano-ceramic restorative material.
Clinical Oral Investigations
10
3
:
181
186
.
59
Schoch
,
M.
,
N.
Kramer
,
R.
Frankenberger
, and
A.
Petschelt
.
1999
.
Direct posterior composite restorations with a new adhesive system: One-year results.
The Journal of Adhesive Dentistry
1
2
:
167
173
.
60
Hugo
,
B.
,
A.
Stassinakis
,
N.
Hofmann
,
P.
Hausmann
, and
B.
Klaiber
.
2001
.
In vivo study of small Class II composite fillings [In-vivo-Untersuchung von kleinen Klasse-II-Kompositfüllungen].
Schweizerische Monatsschrift für Zahnmedizin
111
1
:
11
18
. (
article in German
).
61
Walshaw
,
P. R.
and
D.
McComb
.
1994
.
SEM evaluation of the resin-dentin interface with proprietary bonding agents in human subjects.
Journal of Dental Research
73
5
:
1079
1087
.

Author notes

Hartmut Schneider, Dipl-Phys, Dr rer nat, research scientist, Department of Conservative Dentistry and Periodontology, University of Leipzig, Leipzig, Germany

Ingeborg Busch, Dr med, dentist, Department of Conservative Dentistry and Periodontology, University of Leipzig, Leipzig, Germany

Matthias Busch, Dr med dent, dentist, Department of Conservative Dentistry and Periodontology, University of Leipzig, Leipzig, Germany

Holger Jentsch, Dr med habil, professor, Department of Conservative Dentistry and Periodontology, University of Leipzig, Leipzig, Germany

Matthias Häfer, Dr med, dentist, Department of Conservative Dentistry and Periodontology, University of Leipzig, Leipzig, Germany