SUMMARY
This study evaluated Streptococcus mutans biofilm adhesion on the surface of three composite resins (nanofilled, Filtek Z350, 3M ESPE, Salt Lake City, UT, USA; nanohybrid, Vit-1-escence, Ultradent Products, South Jordan, UT, USA; and microhybrid, Esthet X, Dentsply, Milford, DE, USA) following different finishing and polishing techniques. Sixty standardized samples (6 × 3 mm) of each composite were produced and randomly divided into three finishing and polishing treatments (n=20): 1) control group: composite resin surface in contact with Mylar matrix strips with no finishing or polishing performed, 2) Sof-Lex aluminum oxide disc technique (3M ESPE, and 3) carbide bur finishing and Astrobrush polishing technique (Ultradent). Half the samples of each group were incubated in human saliva for 1 hour, and all the samples were subjected to S mutans (ATCC 35688) biofilm development. The mean log of CFU/mL present in the S mutans biofilm was calculated, and data were statistically analyzed by three-way analysis of variance and the Tukey test (p<0.05). Human saliva incubation promoted a significant increase of bacterial adherence on all three of the composites' surfaces, regardless of the polishing treatment performed (p<0.05). Of the three, the nanofilled composite (Filtek Z350) had the lowest bacterial adherence with each of the finishing and polishing techniques despite the presence or absence of human saliva (p<0.05). Mylar matrix strips (control group) promoted the lowest bacterial adhesion on the surface of the microhybrid and nanofilled composites in the absence of human saliva.
INTRODUCTION
The development and refinement of composite resins intends to minimize and eliminate the critical drawbacks of the polymer-based materials such as polymerization contraction, fatigue, occlusal wear, organic matrix degradation, surface roughness, insufficient contour, and interdental contacts and fractures.1,2
Some clinical procedures, such as finishing and polishing, can improve the performance and longevity of these materials. The finishing procedure aims at an adequate anatomy, whereas polishing decreases surface roughness and minimizes the microgaps produced by the finishing instruments. In addition, roughness of the composites' surface also relies on the chemical composition and mechanical characteristics of these materials.3-6
Organic matrix and inorganic particles present different hardnesses and, as a consequence, undergo distinct wear when subjected to occlusal forces. Because of its lower hardness, the organic matrix degrades faster and exposes the inorganic fillers which are then dislodged by attrition. Therefore, the larger the particle size, the greater the roughness left by the inorganic filler.7-11
In view of the fact that the type, size, and quantity of inorganic filler influence the mechanical properties and polishing of polymer-based materials,12 nanometric-sized composite fillers were developed in order to produce composites with improved mechanical and esthetic characteristics due to the reduced sized and wide distribution of the fillers.6,10
The abrasive particles of the polishing materials must exhibit hardness superior to that of the inorganic fillers of the composites to avoid excessive wear of the organic matrix.5,13 In addition, the surface geometry and proper operatory handling also influence polishing of composites.14 Aluminum oxide discs are available for finishing and polishing of resins; however, the shape of these instruments is inadequate for occlusal surfaces.5,7,10,15-18 In order to reach and properly polish occlusal posterior surfaces, multifluted carbide burs, diamond burs, brushes, abrasive pastes, and silicon carbide burs are commonly used in clinical practice.18-20
A noticeably polished composite surface ensures esthetic attributes and significantly decreases the risk of initial bacterial adherence and subsequent colonization. It will also decrease periodontal disease, marginal discoloration, and secondary caries progress promoted specifically by Streptococcus mutans and Streptococcus sobrinus, the most prevalent streptococci in human dental caries.7,10,11,21-24
Based on the facts described, the aim of this study was to evaluate S mutans biofilm adherence on the surface of nanofilled, nanohybrid, and microhybrid composites submitted to different polishing and finishing techniques.
MATERIALS AND METHODS
Experimental Design
The factors under study were as follows:
Composite resins (three levels: nanofilled, nanohybrid, and microhybrid)
Finishing and polishing treatments (three levels: control, no finishing or polishing performed; aluminum oxide discs; and 30-blade carbide tungsten burs followed by silicon carbide brushes)
Saliva incubation (two levels: with and without)
The experimental units consisted of standardized composite samples subjected to different surface treatments. The response variable was the mean CFU/mL present in the S mutans biofilm formed on the composite resin surface. Data were statistically analyzed by three-way analysis of variance (ANOVA) and the Tukey test (p<0.05).
Sample Preparation
Samples (n=60) of each composite were prepared in a cylindrical-shaped Teflon mold 6.0 mm in diameter and 3.00 mm in height. The mold was filled in a single increment with the nanofilled composite (Filtek Z350TM, 3M/ESPE, Salt Lake City, UT, USA), the nanohybrid composite (Esthet XTM, Dentsply, Milford, DE, USA), or the microhybrid composite (Vit-l-escenceTM, Ultradent Products, South Jordan, UT, USA) and covered with a Mylar matrix strip. The top surface was cured for 40 seconds in a curing unit device (Optilux 401, Demetron/Kerr, Danbury, CT, USA) operating between 700 and 800 mW/cm2. Samples were retrieved from the mold, the excess resin was removed with surgical blades, and samples were individually immersed in dark vials containing distilled water at 37°C for 24 hours. The composition and manufacturer of the composites tested are displayed in Table 1.
Polishing Treatment
Twenty samples of each composite (nanofilled, nanohybrid, and microhybrid) were submitted to one of three finishing and polishing techniques (n=20):
Control group—the surface remained intact after contact with the Mylar matrix strip, and no finishing or polishing procedures were performed.10
Aluminum oxide discs (Sof-LexTM, 3M ESPE).
30-blade tungsten carbide burs (Beavers Dental, Morrisburg, ON, Canada) and silicon carbide brushes (AstrobrushTM, Ivoclar, Vivadent, Schaan, Principality of Liechtenstein).
In group B, samples were polished with a sequence of four sandpaper discs (Sof-Lex coarse: 100 μm; medium: 29 μm; fine: 14 μm; and superfine: 5 μm) for 30 seconds each in a single direction. At each disc exchange, the composite surface was washed and air dried for 5 seconds. A new polishing disc was used after every fifth sample. Group C was polished with tungsten carbides for 30 seconds, washed and air dried for 5 seconds, and then finished with silicon carbide brushes for 30 seconds in a single direction. All samples from groups A, B, and C were placed into sterilized Petri dishes (24 wells, Costar, New York, NY, USA) and sterilized in a 20-kGy gamma radiation chamber (cobalt 60) for 6 hours (Embrarad, São Paulo, Brazil).
Human Saliva Incubation
Whole unstimulated saliva, was collected from six healthy subjects which was approved by the Ethical Committee of Research of the University of Taubaté (126/08). Human saliva donors presented low biofilm formation (as verified by the Silness and Löe Index) and a S mutans number lower than 106 colony-forming units per milliliter (CFU/mL) of saliva. Immediately after collection, the saliva was added to pooled saliva protease inhibitor phenyl methyl sulfonyl hydrofluoric and sodium azide (20 μL/mL of saliva). The pooled saliva was centrifuged for 20 minutes at 4°C at 20,000g (MPW-350R, Biosystems, Pinhais, Brazil) to remove debris, then frozen at −4°C until needed for the experiment. Before use, the pooled saliva was thawed and filtrated with a cellulose acetate filter with a pore diameter of 0.22 μm (Millipore membrane, São Paulo, Brazil). Half the samples of each group were incubated in 1.5 mL of sterilized human saliva for 1 hour.
Biofilm Adhesion
A standard suspension of S mutans (ATCC 35688) containing 106 cells/mL was prepared. For this purpose, S mutans was seeded onto brain heart infusion (BHI) agar (Difco, Detroit, MI, USA) and incubated for 24 hours. All incubation was carried out at 37°C in a CO2 chamber. After incubation, the growth was suspended in sterile physiological solution (0.9% sodium chloride (NaCl]), and the number of cells in suspension was counted in a spectrophotometer (B582, Micronal, São Paulo, Brazil). The parameters of optical density and wavelength used were, respectively, 0.620 and 398 nm. These parameters were previously established by means of a standard curve with CFU vs. absorbance. Adherence testing was performed in an aseptic environment in a laminar airflow chamber. The broth used for adherence was proposed by Gybbons and Nygaard25 and contains 20 g tripticase, 2 g NaCl, 3 g K2HPO4, 2 g KH2PO4, 1 g K2CO3, 120 mg MgSO4, 15 mg MnSO4, and 50 g C6H8O7 dissolved in 1000 mL of distilled water. The broth was sterilized by autoclaving at 121°C for 15 minutes. In each well of sterile 24-well polystyrene tissue culture plates was placed one specimen, 1.5 mL of broth, and 0.1 mL of standardized S mutans suspension. The plates were sealed and incubated at 37°C for 24 hours in a CO2 chamber. Samples were then removed and washed twice with sterile physiological solution (0.9% NaCl) in order to remove loosely bound material. Following this, the samples were placed in tubes with 3 mL of sterile physiological solution (0.9% NaCl) and sonicated (Sonoplus HD 2200, 50 W, Bandelin Electronic, Berlin, Germany) for 30 seconds to disperse the biofilms. The suspension obtained was diluted 10, 100, and 1000 times, and aliquots of 0.1 mL were seeded in duplicate onto BHI agar and incubated for 48 hours at 37°C in a CO2 chamber. After the incubation, the plates with 30 to 300 typical colonies of S mutans were counted in a colony counter (Phoenix CP-600, São Paulo, Brazil), and mean values of CFUs were obtained (CFU/mL). Mean values of CFU/mL were converted into logarithmic (log10) values and analyzed by three-way ANOVA and the Tukey test. A p value <0.05 was considered to indicate a statistically significant difference.
RESULTS
Mean and standard deviation values of the CFU/mL (log10) of S mutans within the biofilms formed are displayed in Table 2. The presence of saliva increased bacterial adhesion for all composites tested, regardless of the finishing and polishing treatment performed (p<0.05). The nanofilled composite (Filtek Z350TM) presented the lowest bacterial adhesion among composites, regardless of the groups (A, B, or C) or the presence/absence of human saliva (p<0.0001).
In the absence of human saliva, Mylar matrix strips (group A) promoted the lowest bacterial adhesion in the nanofilled and microhybrid composites (Filtek Z350TM and Vit-l-escenceTM), whereas for nanohybrid resin (Esthet XTM), groups A and C were similar and showed lower bacterial adhesion than group B.
In the presence of saliva, bacteria adhesion in nanohybrid and microhybrid composites (Esthet XTM and Vit-l-escenceTM) were similar for all finishing and polishing treatments performed (A, B, or C; p>0.0518). In contrast, nanofilled composite (Filtek Z350TM) exhibited the lowest bacterial adhesion when no finishing or polishing was performed (group A).
DISCUSSION
Clinical procedures such as finishing and polishing of restorations are important to improve the performance and longevity of resin composites. Besides the esthetic considerations, polishing is performed in order to minimize surface roughness and crevices created by the finishing instruments, thus increasing the clinical longevity of restorations and minimizing biofilm formation.3-5 As a consequence, the polished surface of a composite decreases the possibility of periodontal disease, marginal discoloration, and secondary caries.7,10
The results of the present study demonstrated that the inherent characteristics of the composite resin tested, the finishing and polishing techniques performed, and the presence of human saliva influence S mutans adhesion to the composite surface.9,21,22
In the absence of human saliva, Mylar matrix strips (group A) produced the lowest bacterial adhesion on the nanofilled and microhybrid surfaces, whereas nanohybrid resin exhibited lower adhesion for both group A and group C. These results are in accordance to previous findings in which the composite surface polymerized against Mylar matrix strips exhibited flatter surfaces compared to finished and polished composites.16,26,27
Although polyester matrix strips promote the smoothest surface in the absence of saliva, most clinical situations require bulk removal of excess composite. Additionally, finishing and polishing techniques are necessary to remove the monomer-rich surface layer of the composite material.28 This eventually eliminates the organic matrix, exposing and dislodging the filler particles, thus increasing the surface roughness of polymer-based materials.16
Among finishing and polishing techniques, it has been reported that the Sof-LexTM aluminum oxide discs technique provides a smoother surface on composites compared to carbide bur finishing followed by the AstrobrushTM technique.27 In the present study, however, polishing with aluminum oxide discs (group B) promoted surface roughness similar to polishing with brushes (group C), except for nanohybrid composite (Esthet XTM) without saliva incubation. This indicates that polishing treatment C was the best treatment alternative for this composite in this particular situation.
It must be kept in mind that although the Sof-LexTM technique promoted surface bacterial adhesion similar to the AstrobrushTM technique for some groups, the use of discs is limited because of the geometry of the surface to be polished. Aluminum oxide discs are unable to efficiently create, finish, and anatomically polish contoured surfaces, especially posterior occlusal surfaces.27
A lower S mutans biofilm adhesion rate is observed on nanofilled resin surface in the presence or absence of human saliva, confirming that biofilm adhesion varies according to filler size, shape, distribution, and matrix monomer.6,9,10,21,22 The inorganic filler of Filtek Z350TM is a combination of nonagglomerated 20-nm nanosilica filler and loosely bound agglomerated zirconia/silica nanoclusters, which consists of agglomerates of primary zirconia/silica particles with a filler size of 5-20 nm. The reduced size and the wide distribution of the fillers reduces roughening after finishing and polishing, consequently decreasing S mutans adherence.
The samples of our study incubated in human saliva exhibited a significant increase of S mutans biofilm growth to nanofilled, nanohybrid and microhybrid composites and demonstrated the powerful ability of salivary components to modulate biofilm adhesion as oral bacteria adhere to receptors of the host origin in saliva pellicle.29
The selection of S mutans to promote biofilm adhesion is based on the fact that these microorganisms are recognized as the major etiological agent of human dental caries, are harbored in mature plaque, and represent a significant amount of the oral streptococci in caries lesions.9 S mutans adherence to enamel surface and to restorative materials is a preliminary condition to biofilm formation and can eventually promote secondary caries and periodontal diseases.21,24
This study observed that S mutans biofilm adhesion to composite resin surfaces is influenced by the composition of composites, finishing and polishing performed, and the presence of saliva pellicle.
The quality and amount of adhered biofilm are important to the success of the esthetic restorations on a long-term basis. The initial adherence and subsequent colonization of bacteria on the surface of composite resins is the key of the pathogenesis of the secondary caries promoted particularly by S mutans and S sobrinus. Therefore, further in situ studies should be executed to confirm the results of this in vitro observation.
CONCLUSIONS
Within the limitations of this in vitro study, the following were concluded:
Human saliva pellicle increased S mutans adhesion to all composite restorative materials tested.
Nanofilled composite resin presented the lowest bacterial adhesion among composites.
Mylar matrix strips promoted the smoother surface among polishing treatments in the absence of human saliva.
Acknowledgment
The author Cristiane A. Pereira is grateful to FAPESP for the scholarships provided (Process 2010/00879-4).
REFERENCES
Author notes
Cristiane Aparecida Pereira, MSc, PhD student, Department of Biosciences and Oral Diagnosis, School of Dentistry of São José dos Campos, UNESP – Univ Estadual Paulista, São José dos Campos, Brazil
Evania Eskelsen, DDS, MSc, PhD, research scientist, Department of Dentistry, University of Taubaté, Taubaté, Brazil
Vanessa Cavalli, DDS, MSc, PhD, professor, Department of Dentistry, University of Taubaté, Taubaté, Brazil
Priscilla Christiane Suzy Liporoni, DDS, MSc, PhD, professor, Department of Dentistry, University of Taubaté, Taubaté, Brazil
Antonio Olavo Cardoso Jorge, DDS, MSc, PhD, chairman and professor, Department of Biosciences and Oral Diagnosis, School of Dentistry of São José dos Campos, UNESP – Univ Estadual Paulista, São José dos Campos, Brazil
Marcos Augusto do Rego, DDS, MSc, PhD, Prof Dr, Departament of Dentistry, University of Taubaté, Brazil