The present in vitro study concerns determination of the pre-cementation gap width of all-ceramic crowns made using an in-office digital-impression technique and subsequent computer-aided design/computer-aided manufacturing (CAD/CAM) production. Two chairside video camera systems were used: the Lava Oral scanner and Cadent's iTero scanner. Digital scans were made of a first molar typodont tooth that was suitably prepared for an all-ceramic crown. The digital impressions were sent via the Internet to commercial dental laboratories, where the crowns were made. Also, an impression of the typodont tooth was made, poured, and scanned in order to evaluate the pre-cementation gap of crowns produced from scanning stone dies. These methods and systems were evaluated by creating replicas of the intermediate space using an addition-cured silicone, and the gap widths were determined using a measuring microscope. Hot-pressed leucite-reinforced glass-ceramic crowns were selected as a reference. The mean value for the marginal measuring points of the control was 170 μm, and the values for all the evaluated crowns ranged from 107 to 128 μm. Corresponding figures for the internal measuring points were 141-210 μm and 115-237 μm, respectively. Based on the findings in the present study, an in-office digital-impression technique can be used to fabricate CAD/CAM ceramic single crowns with a marginal and internal accuracy that is on the same level as that of a conventional hot-pressed glass-ceramic crown. In the present study, however, slight differences could be seen between the two types of ceramic crowns studied with respect to the internal fit obtained.

The marginal and internal fit of dental restorations, such as inlays and crowns, is crucial for the clinical outcome of dental restorations. During the past few decades various impression and die materials have been used in dentistry,1-3  and marginal and internal fit has been determined using a variety of measuring techniques: cementing on extracted teeth or replicas and subsequent slicing of the restorations and the teeth/replicas,4-6  direct measurement with light microscope,7,8  or replica technique with polyvinyl-siloxane impression materials.9-10 

Currently, most impression materials have to be sent by mail and/or courier to dental laboratories despite the possible risk of the impressions being disease carriers as disinfection of impression materials is problematic.11,12  To avoid the use of impression materials, attempts to determine the shape of preparations for dental restorations using various mechanical and/or optical systems were presented in the 1970s,13  but as far as we know, they were not routinely used in clinical practice. Later, around the middle of the 1980s, a system for electronically designing and milling ceramic restorations was introduced in dentistry.14  This system used a three-dimensional (3D) miniature video camera to stereo-photogrammetrically scan the cavity preparation and make a 3D pattern of the tooth preparation, which could then be stored in a chairside microprocessor unit and, in combination with a numerically controlled miniature three-axis milling device, the restorations could be milled from prefabricated ceramic blocks.14  Because it was a completely new way of producing dental restorations, the precision of the final restorations was questioned and was of particular interest. Thus, several studies addressing the internal and marginal fit of these restorations were presented; these stated, among other things, that the properties of the luting agents used, the shape of the preparation and the restoration, and the location of the measuring points could influence the outcome.6,8-14  Recently, a number of improved versions of 3D miniature video cameras, in combination with improved microprocessors, have been introduced in dentistry. Examples of such systems are the Cerec AC (Sirona Dental Systems GmbH, Bensheim, Germany), E4D CADCAM system (Ivoclar AG, Schaan, Lichtenstein), Cadent's iTero (Cadent Inc, Carlstadt, NJ, USA), and Lava Chairside Oral Scanner C.O.S. (3M ESPE, St Paul, MN, USA).15 

These systems are said to be improvements on the earlier types of equipment intended for digitalizing dental preparations15  and should thus produce better internal and marginal fit for the restorations. The aim of the present work was, therefore, to determine the marginal and internal pre-cementation space in ceramic crowns made using two of the recently introduced systems and to compare the results with ceramic crowns made after taking impressions with an addition-cured silicone and using conventional die stone models, wax copings, and subsequent press casting.

The internal and marginal fit was determined for two different types of all-ceramic crowns, which were made using two types of digital impression systems: the Lava Chairside Oral Scanner C.O.S. and Cadent's iTero systems.

A ∼1.5-mm chamfer preparation was made for an all-ceramic crown on a maxillary right first phantom Frasaco molar (Frasaco GmbH, Tettnang, Germany) placed in a maxillary Frasaco model (Figure 1). The maxillary Frasaco model was placed in a Frasaco phantom head (Figure 2), and digital impressions, using the Lava or the Cadents iTero scanning systems, were made of the prepared phantom molar and the surrounding area and the opposing teeth, in accordance with the manufacturer's instructions. The digital impressions were then sent via the Internet to two different commercial dental laboratories experienced in fabricating the relevant types of crowns. One laboratory produced nine iTero all-ceramic crowns, and the other laboratory produced nine Lava all-ceramic crowns. In the following text those crowns are referred to as ”iTero Oral” and ”Lava Oral,” respectively.

Figure 1.

Shape of the prepared maxillary right first phantom Frasaco molar with a ∼1.5-mm chamfer preparation placed in a Frasaco phantom model.

Figure 1.

Shape of the prepared maxillary right first phantom Frasaco molar with a ∼1.5-mm chamfer preparation placed in a Frasaco phantom model.

Close modal
Figure 2.

A phantom Frasaco model placed in a Frasaco phantom head.

Figure 2.

A phantom Frasaco model placed in a Frasaco phantom head.

Close modal

In addition, to study the effect on the marginal and internal gap width of producing Lava and iTero crowns after scanning die stone models made from impressions of the prepared molar and the surrounding and opposing areas, addition-cured silicone impressions were made (Provil Novo Light body, batch number 310309, and Provil Novo Medium, batch number 320079, Heraeus Kulzer GmbH, Hanau, Germany). These silicone impressions were then sent to two different commercial dental laboratories experienced in the technique. Thereafter, one dental laboratory did the scans for the Lava crowns and another for the iTero crowns. The scanned files were used to produce nine Lava and nine iTero crowns, respectively. In the following text these crowns are designated “iTero Die Stone” and “Lava Die Stone”.

Hot-pressed leucite-reinforced glass-ceramic crowns (Empress, Ivoclar Vivadent AG, Schaan, Lichtenstein) were selected as the reference. After taking impressions of the prepared molar and the surrounding and opposing areas with an addition-cured silicone (Provil Novo Light body, batch number 310309, and Provil Novo Medium, batch number 320079), nine Empress crowns were made by one of the authors (KO) and a dental technician at the Department of Odontology, Umeå University, who was specially trained in the Empress technique using conventional die stone models (Vel-Mix Die Stone, Type IV, Kerr Dental Laboratory Products, Orange, CA, USA), wax copings, and subsequent press casting.

After all the crowns were produced, replicas of the intermediate space between the inner surface of the crowns and the prepared Frasaco tooth surface were taken with an addition-cured silicone (Provil Novo, Heraeus Kulzer GmbH). The crowns were filled with the addition-cured silicone light-body impression material (Provil Novo Light, batch number 310309, color green), placed on the prepared Frasaco tooth, and held in position using finger pressure for 4 minutes at room temperature. After the light-body impression material had polymerized, the crowns were removed and the thin film of the impression material that dressed the outside of the prepared Frasaco tooth or the inside of the crown was covered by a medium-body impression material (Provil Novo Medium, batch number 320079) that differed in color (yellow) from the light-body material. After polymerization, the light-body and the medium-body impression materials were removed en bloc. Three persons made the replicas: one person made 20 of the Lava Oral replicas, another person made 23, and a third person made two. Because the medium-body impression material joined the light-body replicas in one piece, they could be cut with a scalpel in two directions: one corresponding to the mesiodistal (Figure 3A) and one to the buccolingual (Figure 3B). That is, the replicas were divided into four pieces, and because the light-body and the medium-body impression materials were different colors (green and yellow, respectively), the discrepancy between the master model and the frameworks representing the cement space could be distinguished (Figure 3a,b). The gap width was then measured using a Leitz UWM-DigS measuring microscope (Esselte Leitz GmbH & Co KG, Stuttgart, Germany) at 19 preselected locations (Figure 3a,b) on each half of the sectioned replicas at 20× magnification, giving a total of 38 measuring points for each crown. The gap width was measured as the thickness of the light-body impression material at the measuring points in Figure 3a,b. The same person carried out all the measurements without knowing the identity of the specimens.

Figure 3.

Example of an addition silicone replica of the marginal width. The letters indicate the selected measuring points. Darker shade = light body; lighter shade = medium body. (a): Denotes the letters of the measuring points in the mesiodistal direction; (b): Denotes the letters of the measuring points in the buccolingual direction.

Figure 3.

Example of an addition silicone replica of the marginal width. The letters indicate the selected measuring points. Darker shade = light body; lighter shade = medium body. (a): Denotes the letters of the measuring points in the mesiodistal direction; (b): Denotes the letters of the measuring points in the buccolingual direction.

Close modal

Statistical Analysis

The values were statistically analyzed using an independent t-test at a significance level of p<0.05 after Bonferroni correction p <0.01. The data were analyzed using SPSS statistical software, version 20 (Statistical Package for Social Science, SPSS Inc, Chicago, IL, USA).

The results and statistical analyses are summarized in Tables 1 and 2. Statistical analysis (section A of Table 2) of all the measuring points, that is, measuring points A-S in Figure 3, revealed that the gap width was significantly wider (p<0.001) for the Empress crowns (control) than for the Lava Oral crowns, whereas there were no significant differences between Empress and Lava Die Stone, iTero Oral, and iTero Die Stone. The Lava Oral crowns showed a significantly (p<0.01) smaller gap width than the other groups.

Table 1:

Summary of the Gap Widths at the Various Measuring Points

Summary of the Gap Widths at the Various Measuring Points
Summary of the Gap Widths at the Various Measuring Points
Table 2:

Summary of the Statistical Analysisa

Summary of the Statistical Analysisa
Summary of the Statistical Analysisa

Comparison of the marginal measuring points, that is, measuring points A, I, J, and S in Figure 3, showed that the marginal gap width was significantly (p<0.01) wider for Empress than for all the other groups (section B in Table 2).

For the proximal measuring points, that is, measuring points B, H, K, and R in Figure 3, there were no significant differences between the Empress and the other groups tested, whereas the gap width for the iTero Die Stone was significantly (p<0.001) wider than for the iTero Oral. For the Lava Die Stone, the proximal gap width was significantly wider (p<0.001) than for the iTero Oral crowns (section E in Table 2).

At the proximal-occlusal measuring points, that is, measuring points C, G, L, and Q in Figure 3, there were no significant differences between Empress and the other groups tested. The gap width for the iTero Oral crowns was significantly wider than for Lava Oral (p<0.01). No statistically significant differences were seen among the other groups of crowns studied for the proximal-occlusal measuring points (section D of Table 2).

The occlusal gap width, that is, measuring points D, E, F, M, N, O, and P in Figure 3, was significantly wider for the iTero Oral crowns than for the Empress, Lava Oral, and iTero Die Stone crowns (p<0.001). The Lava Die Stone crowns exhibited a significantly (p<0.001) wider occlusal gap width than the Empress, Lava Oral, and iTero Die Stone crowns (section E of Table 2).

The purpose of the present study was to evaluate the accuracy of ceramic crowns produced by means of in-office scanning of the preparation and subsequent computer-aided design/computer-aided manufacturing (CAD/CAM) production technologies. Today, dental CAD/CAM technology has expanded well beyond the initial version of the Cerec system introduced in the middle of the 1980s, and a number of CAD/CAM restorative technologies are currently on the market.15  To evaluate the ability of the recently introduced in-office scanning and CAD/CAM restorative technologies to produce all-ceramic crowns with acceptable marginal and internal fit, two such systems, 3M ESPE Lava COS and Cadents iTero, were used. To copy the clinical situation as closely as possible, a digital impression of the scanned preparation was sent via the Internet to commercial dental laboratories trained in the technique of manufacturing this type of ceramic crown. In addition, the present study evaluated the marginal and internal fit of crowns made after the preparation was scanned from die stone models constructed from polyvinyl-siloxane impressions of the prepared phantom Frasaco model. Hot-pressed leucite-reinforced glass-ceramic crowns (IPS Empress) were used as a control. The IPS Empress crowns were selected for this purpose because this type of all-ceramic crown has been in clinical use for a long time.16,17 

In the present work, replicas of the space between the inner surface of the crowns and the prepared tooth were made, using a polyvinyl siloxane addition-cured silicone, to determine the gap widths. This technique was selected as it has been determined that using light-body addition-cured polyvinyl-siloxane impression materials for the replica technique is a reliable and commonly accepted method for evaluating clinical accuracy.18-24  In addition, it has been shown that the gap-width values obtained using this technique are similar to those obtained after luting with glass-ionomer cement.19  Other techniques for determining gap widths of dental restorations are using a light microscope directly after the restoration is placed on the prepared tooth or die stone8  or luting the restorations on extracted teeth and then sectioning the crowns and teeth to determine the gap width.8  When using light microscopy directly, only the marginal gap width can be determined,8  and when using a number of prepared teeth and then sectioning the crowns/teeth, the gap width could be influenced by such factors as the design of the prepared teeth.25-28  It should be noted, however, that with the replica technique used in the present study the crowns were filled with light-body impression material and held in place with finger pressure. This could have resulted in a variable force applied on the crowns, but the experimental setup imitates the way crowns are usually placed in patients.

In the present study all the crowns produced using scanning and CAD/CAM production, irrespective of type or whether they were made via die stone models or directly from the prepared tooth, exhibited marginal fit that was smaller than for the control. At the proximal and proximal-occlusal measuring points, no significant differences could be seen compared with the control, whereas occlusally the control exhibited a significantly smaller gap width than the iTero Oral and Lava Die Stone crowns. It should be noted that the controls were manually produced using the lost wax technique and die spacer, whereas Lava and iTero were digitally produced crowns. Because it is difficult to exactly reproduce the die spacer thickness and manually produce the crowns, this can be one of the reasons for the discrepancy in gap widths and the error distribution observed between the manually and digitally produced crowns (Table 1).

However, it is still not known what gap distance is clinically optimal or what effect the selection of the location of the measuring points has. McLean and Fraunhofer29  conclude that 120 μm is the maximum tolerable marginal opening, but previous studies reported mean gap widths ranging from 9 to 215 μm in dental restorations and a gap width of 420 μm at the marginal measuring point and 850 μm at the occlusal measuring point.30-34  In a previous study of heat-pressed Empress crowns cemented to dies with zinc phosphate cement the marginal gap widths reported range between 26 and 548 μm.35  In a recently presented study using Lava COS and Cerec intraoral scanning systems (Sirona, Bensheim, Germany), the gap widths determined using silicone replicas ranged between 0 and 552 μm.36  That is, in the previous studies30-36  there was a huge spread in the gap widths, which supports the findings in the present study. Thus, the results obtained in the present study are within the ranges reported in previous studies, although the values reported for the Empress crowns were obtained for crowns luted to dies with zinc phosphate cement and sectioned before measuring the gap width.35  It should be noted, however, that conditions in the studies varied and there is no standardized method for determining the accuracy of dental crowns, making comparison difficult. Most of the studies referred to earlier30-36  include restorations produced by means of conventional impression techniques or scanning from die stone models, and in a survey of the literature, only one article was found that addressed the internal and marginal fit of ceramic crowns made using in-office scanning of the preparation and subsequent CAD/CAM production.36  One interesting finding in the previous study of Lava crowns36  was that the values were almost identical to those obtained in the present study, with the exception of those for the marginal fit. Possible explanations for the divergent gap width determined in the three studies could be that the there were slight differences in convergence angle and/or in the finishing margin design of the prepared teeth and/or differences in preparation depth.25-28 

Regarding the internal fit, internal discrepancies may weaken the ceramic crowns, so the marginal and internal fits are among the important criteria for the long-term success of ceramic restorations. For example, because the space between the tooth and the restoration exposes the luting material to the oral environment, a wide gap discrepancy may cause cement solubility, plaque accumulation, marginal leakage, and crown failures. Inadequate marginal fit is also said to be the most significant factor in the development of caries.37  Today the recommended method for many types of all-ceramic restorations, such as IPS Empress, is adhesive luting using resin composite, which may be less soluble in oral fluids than conventional zinc phosphate and glass-ionomer cements.38,39  However, it should be emphasized that restorations made of oxide ceramics may be luted with conventional zinc oxide phosphate or glass-ionomer cements.40-42  In this context it should be noted that glass-ionomer and zinc oxide phosphate cements exhibit higher solubility than resin composite.38,39  In addition, the clinical experience of those types of cements is mainly based on metal or porcelain-fused-to-metal restorations, and mean values for the marginal fit of such crowns have been reported to range between 31 and 72 μm.43-45  More long-term follow-up studies are, therefore, necessary to determine the optimal internal and marginal fit of all-ceramic dental restorations.

All the crowns in the present study made via scanning and subsequent CAD/CAM production showed marginal fit that was less than that of the control. At the proximal and proximal-occlusal measuring points, however, there were no significant differences between the studied crowns and the control. Occlusally, the gap width for iTero Oral and Lava Die Stone was wider than for the control. Thus, based on the findings of the present study, an in-office digital-impression technique can be used in vitro to fabricate CAD/CAM ceramic single crowns with a marginal and internal accuracy that is on the same level as that of a conventional hot-pressed glass-ceramic crown. In the present study, slight differences could be seen between the two types of ceramic crowns studied with respect to internal fit. However, it should be noted that the gaps determined in the present study are almost two times higher than those reported for cast metal or porcelain-fused-to-metal crowns and that the present study is an in vitro comparison study. More studies are, therefore, necessary to validate the ability of in-office digital-impressions in clinical situations.

The authors of this manuscript certify that they have no proprietary, financial, or other personal interest of any nature or kind in any product, service, and/or company that is presented in this article.

1
Hansson
O
,
&
Eklund
J
(
1984
)
A historical review of hydrocolloids and an investigation of the dimensional accuracy of the new alginates for crown and bridge impressions when using stock trays
Swedish Dental Journal
8
(
2
)
81
-
95
.
2
Chee
WW
,
&
Donovan
TE
(
1992
)
Polyvinyl siloxane impression materials: a review of properties and techniques
Journal of Prosthetic Dentistry
68
(
5
)
728
-
732
.
3
Donovan
TE
,
&
Chee
WW
(
2004
)
A review of contemporary impression materials and techniques
Dental Clinics of North America
48
(
2
)
445
-
470
.
4
Grenade
C
,
Mainjot
A
,
&
Vanheusden
A
(
2011
)
Fit of single tooth zirconia copings: comparison between various manufacturing processes
Journal of Prosthetic Dentistry
105
(
4
)
249
-
255
.
5
Belser
UC
,
MacEntee
MI
,
&
Richter
WA
(
1985
)
Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study
Journal of Prosthetic Dentistry
53
(
1
)
24
-
29
.
6
Sjögren
G
(
1995
)
Marginal and internal fit of four different types of ceramic inlays after luting. An in vitro study
Acta Odontologica Scandinavia
53
(
1
)
24
-
28
.
7
Eden
GT
,
Franklin
OM
,
Powell
JM
,
Ohta
Y
,
&
Dickson
G
(
1979
)
Fit of porcelain fused-to-metal crown and bridge castings
Journal of Dental Research
58
(
12
)
2360
-
2368
.
8
Hickel
R
,
&
Kunzelmann
KH
(
1990
)
The influence of cavity preparation on the width of marginal gaps in Cerec inlays
Deutsche Zahnarztliche Zeitung
45
(
10
)
675
-
677
.
9
Mörmann
WH
,
&
Krejci
I
(
1992
)
Computer-designed inlays after 5 years in situ: clinical performance and scanning electron microscopic evaluation
Quintessence International
23
(
2
)
109
-
115
.
10
Molin
M
,
&
Karlsson
S
(
1993
)
The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study
Acta Odontologica Scandinavia
51
(
4
)
201
-
206
.
11
Blair
FM
,
&
Wassell
RW
(
1996
)
A survey of the methods of disinfection of dental impressions used in dental hospitals in the United Kingdom
British Dental Journal
180
(
10
)
369
-
375
.
12
Bergman
B
(
1989
)
Desinfection of prosthodontic impression materials: a literature review
International Journal of Prosthodontics
2
(
6
)
537
-
542
.
13
Young
JM
,
&
Altschuler
BR
(
1977
)
Laser holography in dentistry
Journal of Prosthetic Dentistry
38
(
2
)
216
-
225
.
14
Mörmann
WH
,
Brandestini
M
,
Lutz
F
,
&
Barbakow
F
(
1989
)
Chairside computer-aided direct ceramic inlays
Operative Dentistry
20
(
5
)
329
-
339
.
15
Kachalia
PR
,
&
Geissberger
MJ
(
2010
)
Dentistry a la carte: in-office CAD/CAM technology
Journal of the California Dental Association
38
(
5
)
323
-
330
.
16
Sjögren
G
,
Lantto
R
,
Granberg
Å
,
Sundström
B-O
,
&
Tillberg
A
(
1999
)
Clinical examination of leucite-reinforced glass ceramic crowns (Empress) in general practices. A retrospective study
International Journal of Prosthodontics
12
(
2
)
122
-
128
.
17
Höland
W
,
Schweiger
M
,
Frank
M
,
&
Rheinberger
V
(
2000
)
A comparison of the microstructure and properties of the IPS Empress 2 and the IPS Empress glass-ceramic
Journal of Biomedical Material Research
53
(
4
)
297
-
303
.
18
Kokubo
Y
,
Tsumita
M
,
Kano
T
,
Sakurai
S
,
&
Fukushima
S
(
2011
)
Clinical marginal and internal gaps of zirconia all-ceramic crowns
Journal of Prosthodontic Research
55
(
1
)
40
-
43
.
19
Rahme
HY
,
Tehini
GE
,
Adib
SM
,
Ardo
AS
,
&
Rifai
KT
(
2008
)
In vitro evaluation of the ”replica technique” in the measurement of the fit of Procera crowns
Journal of Contemporary Dental Practice
9
(
2
)
25
-
32
.
20
Kokubo
Y
,
Ohkubo
C
,
Tsumita
M
,
Miyashita
A
,
Vult von Steyern
P
,
&
Fukushima
S
(
2005
)
Clinical marginal and internal gaps of Procera AllCeram crowns
Journal of Oral Rehabilitation
32
(
7
)
526
-
530
.
21
Kokubo
Y
.
Nagayama
Y
.
Tsumita
M
.
Ohkubo
C
,
Fukushima
S
,
&
Vult von Steyern
P
(
2005
)
Clinical marginal and internal gaps of In-Ceram crowns fabricated using the GN-I system
Journal of Oral Rehabilitation
32
(
10
)
753
-
758
.
22
Tsumita
M
,
Kokubo
Y
,
Ohkubo
C
,
Nagayama
Y
,
Sakurai
S
,
&
Fukushima
S
(
2007
)
Clinical evaluation of marginal and internal gaps of zirconia-based 3-unit CAD/CAM fixed partial dentures
Prosthodontic Society
6
(
2
)
114
-
119
.
23
Obana
J
,
Miyata
T
,
Kouta
M
,
Kawasaki
F
,
Aoyama
S
,
&
Yanagibashi
M
(
1975
)
New application of injection type silicone impression material to prosthodontic field. Part II: fitness test for crowns and bridges
Tsurumi University Dental Journal
1
(
1
)
63
-
68
.
24
Kohorst
P
,
Brinkmann
H
,
Dittmer
MP
,
Borchers
L
,
&
Stiesch
M
(
2010
)
Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses
Journal of Oral Rehabilitation
37
(
4
)
283
-
291
.
25
Shih
A
,
Flinton
R
,
Vaidyanathan
J
,
&
Vaidyanathan
T
(
2011
)
Effect of margin design and processing steps on marginal adaptation of captek restorations ISRN Dentistry 2011(2011)
Article ID 810565, doi:
26
Chan
DC
,
Wilson
AH
Jr,
Barbe
P
,
Cronin
RJ
Jr,
Chung
C
,
&
Chung
K
(
2005
)
Effect of preparation convergence on retention and seating discrepancy of complete veneer crowns
Journal of Oral Rehabilitation
32
(
1
)
58
64
.
27
Iwai
T
,
Komine
F
,
Kobayashi
K
,
Saito
A
,
&
Matsumura
H
(
2008
)
Influence of convergence angle and cement space on adaptation of zirconium dioxide ceramic coping
Acta Odontologica Scandinavia
66
(
4
)
214
218
.
28
Azar
MS
,
Lehmann
KM
,
Dietrich
H
,
Weibrich
G
,
Schmidtmann
I
,
&
Scheller
H
(
2011
)
Effect of preparation depth differences on the marginal fit of zirconia crown copings: an in vitro study
International Journal of Prosthodontics
24
(
3
)
264
-
266
.
29
McLean
JW
,
&
Fraunhofer von
JA
(
1971
)
The estimation of cement film thickness by an in vivo technique
British Dental Journal
131
(
3
)
107
-
111
.
30
Boening
KW
,
Wolf
BH
,
Schmidt
AE
,
Kästner
K
,
&
Walter
MH
(
2000
)
Clinical fit of Procera AllCeram crowns
Journal of Prosthetic Dentistry
84
(
4
)
419
-
424
.
31
Fleming
GJ
,
Dobinson
MM
,
Landini
G
,
&
Harris
JJ
(
2005
)
An in-vitro investigation of the accuracy of fit of Procera and Empress crowns
European Journal of Prosthodontics and Restorative Dentistry
13
(
3
)
109
-
114
.
32
Martínez-Rus
F
,
Suárez
MJ
,
Rivera
B
,
&
Pradíes
G
(
2011
)
Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings
Journal of Prosthetic Dentistry
105
(
2
)
108
-
114
.
33
Grenade
C
,
Mainjot
A
,
&
Vanheusden
A
(
2011
)
Fit of single tooth zirconia copings: comparison between various manufacturing processes
Journal of Prosthetic Dentistry
105
(
4
)
249
-
255
.
34
Kokubo
Y
,
Tsumita
M
,
Kano
T
,
Sakurai
S
,
&
Fukushima
S
(
2011
)
Clinical marginal and internal gaps of zirconia all-ceramic crowns
Journal of Prosthodontic Research
55
(
1
)
40
-
43
.
35
Fleming
GJ
,
Dobinson
MM
,
Landini
G
,
&
Harris
JJ
(
2005
)
An in-vitro investigation of the accuracy of fit of Procera and Empress crowns
European Journal of Prosthodontics and Restorative Dentistry
13
(
3
):
109
-
114
.
36
Brawek
PK
,
Wolfart
S
,
Endres
L
,
Kirsten
A
,
&
Reich
S
(
2013
)
The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systems
Clinical Oral Investigations
Prepublished Jan 31, 2013.
doi
37
Larsson
TD
(
2012
)
The clinical significance of marginal fit
Northwest Dentistry
91
(
1
)
22
-
29
.
38
Hamouda
IM
(
2011
)
Effects of various beverages on hardness, roughness, and solubility of esthetic restorative materials
Journal of Esthetic and Restorative Dentistry
23
(
5
)
315
-
322
.
39
Yanikoğlu N, & Yeşil Duymuş Z
(
2007
)
Evaluation of the solubility of dental cements in artificial saliva of different pH values
Dental Material Journal
26
(
1
)
62
-
67
.
40
Roediger
M
,
Gersdorff
N
,
Huels
A
,
&
Rinke
S
(
2010
)
Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results
International Journal of Prosthodontics
23
(
2
)
141
-
148
.
41
Sorrentino
R
,
Galasso
L
,
Tetè
S
,
De Simone
G
,
&
Zarone
F
(
2012
)
Clinical evaluation of 209 all-ceramic single crowns cemented on natural and implant-supported abutments with different luting agents: a 6-year retrospective study
Clinical Implant Dentistry and Related Research
14
(
2
)
184
-
197
.
42
Ortorp
A
,
Kihl
ML
,
&
Carlsson
GE
(
2012
)
A 5-year retrospective study of survival of zirconia single crowns fitted in a private clinical setting
Journal of Dentistry
40
(
6
)
527
-
530
.
43
Belser
UC
,
Mac Entee
MI
,
&
Richter
WA
(
1985
)
Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscopy study
Journal of Prosthetic Dentistry
53
(
1
)
24
-
29
.
44
Pettenò
D
,
Schierano
G
,
Bassi
F
,
Bresciano
ME
,
&
Carossa
S
(
2000
)
Comparison of marginal fit of 3 different metal-ceramic systems: an in vitro study
International Journal of Prosthodontics
13
(
5
)
405
-
408
.
45
Holden
JE
,
Goldstein
GR
,
Hittelman
EL
,
&
Clark
EA
(
2009
)
Comparison of the marginal fit of pressable ceramic to metal ceramic restorations
Journal of Prosthodontics
18
(
8
)
645
-
648
.