Objectives

To evaluate the effect of surface treatments and bonding systems on the repair bond strength between composite materials after one and 12 months of storage, using an improved microtensile test method.

Methods

A total of 72 composite cylinders (Tetric Evo Ceram, Ivoclar) were fabricated, stored in distilled water for two weeks followed by thermal cycling (5000 times between 5°C and 55°C), and served as substrate. The cylinders were mechanically roughened using 320-grit silicon carbide sandpaper, etched with 37% phosphoric acid gel, rinsed with water, and divided equally into three experimental groups: group 1, unchanged surface; group 2, sandblasting of the surface (CoJet tribochemical silica sand, 3M ESPE; Microetcher II, Danville Engineering Inc); and group 3, surface silane coating (Bis-Silane, BISCO Inc). Eight control cylinders were prepared and underwent similar aging as the substrate. Each experimental group was divided into subgroups that received the following bonding systems: one-step self-etching adhesive (AdheSE One, Ivoclar Vivadent), two-step self-etching adhesive (Clearfil SE, Kuraray America), and three-step etch-and-rinse adhesive (Adper Scotchbond Multi-Purpose, 3M ESPE). Fresh composite (Tetric Evo Ceram, Ivoclar) was placed and cured on top of the prepared substrate cylinders. The specimens were placed in distilled water for a week and thermocycled the same way as before. Eight composite control cylinders were also stored and thermocycled for the same period of time. Half of the cylinders in each test group were tested at one month and the second half at 12 months. The cylinders were serially sectioned in an automatic cutting machine, producing 10 to 20 1.1 × 1.1-mm test specimen beam from each cylinder. Specimens were prepared for microtensile testing and the tensile strength calculated based on the force at fracture and specimen dimension. The fracture surfaces were examined under a stereomicroscope and the type of fracture noted.

Results

The mean tensile strength of composite control was 54.5 ± 6.0 MPa at one month and 49.6 ± 5.1 MPa at 12 months. The mean tensile strength for the repaired groups ranged from 26.4 ± 6.8 MPa to 49.9 ± 10.4 MPa at one month and 21.2 ± 9.9 to 41.3 ± 7.5 at 12 months. There was a statistical difference between all groups (p<0.05) at one month. This difference was less pronounced at 12 months. The highest repair strength was obtained in the group having a silane-coated surface and Clearfil, the two-step self-etching adhesive. Clearfil also had the highest repair strength within each surface treatment group. There was a tendency for lower tensile strength at 12 months compared with one month. Most fractures were of the adhesive type; the highest number of cohesive fractures, 16% at one month and 12% at 12 months, were in groups with the highest tensile strength.

Conclusion

The best repair bond strength was achieved by using freshly mixed silane solution on the substrate in addition to an adhesive, rendering a thin bonding layer.

The replacement of failed restorations is a major dental health care expense and accounts for roughly half of restorative dental work.1-4  Removing faulty bonded-composite restorations is a demanding and time-consuming task. It has been demonstrated in a clinically simulated study that more than twice as much tooth structure was lost when removing composite restorations than comparable amalgam restorations.5  As a consequence, a more conservative and minimally invasive approach—repair rather than replacement of the whole restoration—has been suggested when possible.2,6,7  This approach and philosophy has gradually been adopted by most Western dental schools.8-12  Furthermore, some clinical evidence has been presented that repairing composites increases the longevity of the restorations.13 

Since the introduction of resin composite materials, researchers have explored methods to repair composite restorations by adding new composite to the old.14  New composite can possibly be retained to old composite either through chemical bonding to the filler particles and the organic matrix or through micromechanical bonding to irregularities in the prepared surface.15  It is, however, generally accepted that as composite ages and water uptake occurs, there is a significant reduction in available carboxyl double bonds for chemical polymerization to new composite.16-18  In the last two decades various reports have been published on the repair strength of resin composites. The vast majority of these investigations deal with different surface treatments of the original substrate to be repaired. This includes mechanical roughening with various grits of diamond burs and sandpaper,19-31  abrasion with pumice,32  sandblasting with aluminum oxide or silicatized sand,22,24-42  etching with various concentrations of hydrofluoric acid,22,25-27,31,41,43-45  application of 38% hydrogen peroxide,35  and silane application.19,26,28,30,35,43,46,47  In all these investigations some adhesive was used as a wetting agent in the repair process, in addition to using only flowable composite as an adhesive36  and preheating the repairing composite.34  In the majority of these studies, except in some using shear bond testing, the adhesive testing is performed shortly after the repair process without aging the repaired specimens. From none of these studies has a preferred method emerged to repair bisphenol A glycidyl methacrylate (Bis-GMA)–based composite resin restorations.

Storage in water for different periods is the most common procedure to age the composite to be repaired, and in a few studies thermal cycling, using extreme mouth temperatures, has been applied.23,48  Some less clinically oriented aging methods have also been used, like boiling the specimens for several hours or immersing them in citric acid for a week.48 

Most of the recent studies on repair of composites have examined the repairability of silorane-based restoratives.49-52  In one recent study, however, repairability of many different composites was investigated.25  It was concluded that none of the surface treatments tested could be recommended as a universally applicable repair technique. The effect of adhesive layer thickness on bond strength between composite and dentin has been investigated,53-56  but no work on the effect of the thickness of the adhesive layer when repairing composite could be located.

The main objective of this in vitro investigation is to evaluate the repair bond strength between composite materials using microtensile testing of specimens united by different bonding systems and surface treatments. In addition to three different bonding systems representing self-etch and three-step etch-and-rinse systems, three different surface pretreatments10-12  were used. The tested null hypotheses were as follows: 1) the repair bond strength is independent of the type of the bonding system; 2) the repair bond strength is independent of surface pretreatment; 3) the durability of the repair bond strength decreases over the course of time.

All the restorative materials used in this study are listed in Table 1. The procedure and preparation of the composite cylinders is summarized in Table 2. A total of 72 Tetric Evo Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) composite cylinders, 10 mm in diameter and 6 mm in height, were fabricated in Teflon molds. The composite cylinders were incrementally built in three layers and each layer cured for 40 seconds with a Demetron A2 corded LED curing light (Kerr Corp, Orange, CA, USA). The light output was measured at 1100 mW/cm2 (Norwegian Radiation Protection Authorities, Österaas, Norway). A Mylar strip and glass slide was used at both ends of the Teflon mold to achieve flat-ended specimen blocks. In addition, as a control group, eight composite cylinders of the same diameter and 12 mm in height were incrementally fabricated.

Table 1: 

Materials Used in the Investigation

Materials Used in the Investigation
Materials Used in the Investigation
Table 2: 

Procedure for Preparation of Test Specimens

Procedure for Preparation of Test Specimens
Procedure for Preparation of Test Specimens

After polymerization, the cylinders were immediately stored in distilled water for a total of two weeks.57  The cylinders were further aged by thermal cycling 5000 times between 5°C and 55°C, with a dwell time of 20 seconds and transfer time of three seconds. The 72 cylinders were all surfaced flat with a 320-grit silicon carbide sandpaper disc (Struers, Copenhagen, Denmark) under running water for 5 seconds to obtain a flat surface with standardized roughness.

For cleaning purposes, all the experimental composite cylinders were acid etched with 37% phosphoric acid gel for 15 seconds and rinsed with water for another 15 seconds. The aged cylinders were randomly divided into three experimental groups to have the following surface treatments: Group 1—The 320-grit sandpaper finish unchanged. Group 2—The cylinders were coated with CoJet tribochemical silica sand (3M ESPE, St Paul, MN, USA) using an intraoral sandblaster (Microetcher II, Danville Engineering Inc, San Ramon, CA, USA) for 20 seconds at a distance of about 5 mm. Residual sand was removed by a stream of air for five to 10 seconds. Group 3—The cylinders were coated with Bis-Silane (BISCO Inc, Schaumburg, IL, USA) two-part silane porcelain primer. The two parts were mixed and applied to the test surfaces with a small brush for 30 seconds and gently dried with air for five to 10 seconds to evaporate the solvent. A fourth group contained the eight control cylinders.

Each experimental group was further divided into subgroups, each receiving a different bonding system for repair: a—AdheSE One (Ivoclar Vivadent), a one-step self-etching adhesive; b—Clearfil SE Bond (Kuraray America Inc, New York, NY, USA), a two-step self-etching adhesive, and c—Adper Scotchbond Multi-Purpose (3M ESPE), a three-step etch-and-rinse adhesive. All the adhesives were applied according to the manufacturers' recommendations for placement of composite restorations.

After surface treatment and adhesive application, the original mold was carefully placed over the cylinder and a second mold fitted on the top. The aged composite cylinders were then repaired using Tetric Evo Ceram, shade A2, in three incremental layers, the same way as the original specimens, resulting in 12-mm high specimens. After this, the cylinders were placed in distilled water for a week and then thermocycled 5000 times and finally stored in water for a total of 10 days. Control cylinders were also stored and thermocycled for same period of time. The eight cylinders in each test group were then divided into two groups to be tested either immediately (one month) or after a year of storage in distilled water (12 months). During the 12-month storage period, water was regularly replaced.

The composite cylinders were mounted on an automatic cutting machine (Isomet, Buehler Ltd, Lake Bluff, IL, USA) equipped with a thin, water-cooled diamond blade. The specimens were serially sectioned perpendicularly to the bonding surface, both in the x-axis and the y-axis, producing a number of square test specimen rods approximately 1.1 × 1.1 mm. Ten to 20 test specimens were obtained from each composite cylinder. The test specimens were cleaned ultrasonically in distilled water for 3 minutes. After the cleaning procedure the test specimen rods were examined light microscopically at a magnification of 40× for voids and imperfections in the composite and the adhesive interface and for evaluation of interface thickness. Only flawless specimen rods were tested. The width and thickness of each test specimen was measured to the nearest 0.01 mm using a calibrated digital caliper (Mitutoyo Co, Kawasaki, Japan).

A novel method was developed to attach the specimen rods to the bond testing machine to secure straight alignment of the rods and uniform distribution of the tensile forces throughout the specimens. The 1.1-mm size of the test specimen rods was selected to fit into the female (hollow) end of 2-mm commercially available male/female extension screws (ELRA AS, Oslo, Norway) (Figure 1). An extension screw was fitted to each end of the test specimen rods and secured with cyanoacrylate glue (Locktite 435, Henkel Norden, Gothenborg, Sweden). A custom-fit mold was made to ensure alignment of the screws to the long axis of the specimen.

Figure 1. 

(a): The specimen rod to be tested and the 2-mm male/female extension screws used. (b): The specimen rod fitted, aligned, and secured with cyanoacrylate glue. (c): The specimen assembly attached to the steel wires of the testing machine. (d): The specimen fractured at the repair joint.

Figure 1. 

(a): The specimen rod to be tested and the 2-mm male/female extension screws used. (b): The specimen rod fitted, aligned, and secured with cyanoacrylate glue. (c): The specimen assembly attached to the steel wires of the testing machine. (d): The specimen fractured at the repair joint.

Close modal

Each test specimen was mounted in a calibrated universal testing machine (Lloyd Instruments Ltd, Model LRX, Fareham, England) using specially attached steel wires designed to transmit pure tensile forces to the specimen. The microtensile testing was conducted at a crosshead speed of 1 mm/min until fracture. The tensile bond strength of each test specimen was calculated in megapascals by dividing the imposed force (in newtons) at fracture by the cross-sectional bond area (in millimeters squared). The test specimens were kept moist throughout the preparation of specimens and the test procedure.

The fracture surfaces were examined under a stereomicroscope (American Optical, Buffalo, NY, USA) at 40× magnification to determine whether the failure region was within the adhesive zone or out of it. The adhesive zone was defined as the interface between the old and the new composite. The failure modes were classified as cohesive or adhesive.

The probability of failure in the test specimens was assessed by means of a distribution plot, and the significance of differences was evaluated by a mixed-model analysis of variance (ANOVA) and the Kolmogorov-Smirnov test.58 

The results are presented in Tables 3 to 5. The mean tensile strength of the unrepaired composite control group was 54.5 ± 6.0 MPa at one month and 49.6 ± 5.1 MPa at 12 months. The lowest mean tensile strength in the repaired groups was for group 1c, mechanical roughening with sandpaper + Scotchbond Multi-Purpose, both at one month (26.4±6.8 MPa) and 12 months (21.2 ± 9.9 MPa). This amounts to 48.4% of the strength of the control composite at one month and 42.7% of the strength at 12 months. The highest mean tensile strength for both storage periods was for group 3b, mechanical roughening + silane + Clearfil: 49.9 ± 10.4 at one month and 41.3 ± 7.5 at 12 months, amounting to 91.6% and 83.3% of the control composite strength, respectively. There was a general reduction in the mean tensile strength for the repaired groups after 12 months of storage, amounting from 14.6% to 21.8% of the one-month tensile strength values. In general, Clearfil had the strongest repair strength within each surface treatment group. The mean tensile strength of the unrepaired control composite decreased 8.9% during the same storage period. Statistical calculations using ANOVA and Kolmogorov-Smirnov tests gave similar significance levels for all comparisons. At one month, there was a statistical difference between all groups, which was less pronounced at 12 months (Table 5). There was a tendency for lower tensile strength after one year compared with one month in all groups. However, the difference was not statistically significant. At both observation times, the mean strength of the control composite was significantly higher than that of the strongest repair.

Table 3: 

Results of Microtensile Testing in the Various Groups of Surface Treatment and Bonding Systems After One Month and 12 Months

Results of Microtensile Testing in the Various Groups of Surface Treatment and Bonding Systems After One Month and 12 Months
Results of Microtensile Testing in the Various Groups of Surface Treatment and Bonding Systems After One Month and 12 Months
Table 4: 

Cohesive Fracture in the Various Groups of Surface Treatment and Bonding Systems After One Month and 12 Monthsa

Cohesive Fracture in the Various Groups of Surface Treatment and Bonding Systems After One Month and 12 Monthsa
Cohesive Fracture in the Various Groups of Surface Treatment and Bonding Systems After One Month and 12 Monthsa
Table 5: 

Results of Statistical Calculations by Analysis of Variance and Kolmogorov-Smirnov Tests Evaluating the Difference Between Groups at One Month and 12 Months*

Results of Statistical Calculations by Analysis of Variance and Kolmogorov-Smirnov Tests Evaluating the Difference Between Groups at One Month and 12 Months*
Results of Statistical Calculations by Analysis of Variance and Kolmogorov-Smirnov Tests Evaluating the Difference Between Groups at One Month and 12 Months*

The thickness of the bonding layer using Adper Scotchbond Multi-Purpose varied somewhat but appeared mostly to be approximately 175 μm; the AdheSE One layer was approximately 20 μm; and Clearfil SE, less than 5 μm.

The percentage of cohesive fractures for each group is presented in Table 4. All the cohesive fractures occurred in the old composite. Most cohesive fractures for the repair groups, 16% of specimens at one month and 12% at 12 months, were in group 3b, which also had the highest mean repair strength for both storage periods; group 2b had 7% at 1 month and 11% at 12 months and came in second in mean tensile repair strength. Other groups had fewer or no cohesive failures.

Shear bond strength tests have been widely used when measuring adhesion to dental structures or dental materials. The wide acceptance of this testing method is due to its relative simplicity when compared with tensile strength methods. Some authors have found that conventional shear bond testing produced stress concentrations in the substrate or adherend, leading to cohesive failures when testing adhesive joints and therefore giving misleading results.59,60  This has led to increased use of the microtensile test where, in a very small specimen, comparatively more uniform loading stress distribution is obtained and the tensile forces concentrated in the adhesive interface are tested.61,62  In a review on microtensile bond testing, Pashley62  stated that microtensile testing offered versatility not obtainable with other methods even though it is more labor intensive. Poitevin and others63  reported on composite adhesive strength to dentin and concluded that microtensile testing was a reliable laboratory test in ranking contemporary adhesives on their bonding effectiveness. Recently, a microshear test was introduced to measure bond strength between dentin and resin composite, intended as an alternative to microtensile testing.64,65  The main reason given for using the microshear test was it required a less demanding and time-consuming specimen collection. Only one investigation52  on composite repair using microshear bond testing was found.

Several authors66  have found some evidence for correlation of laboratory bond strength with clinical retention rates of class V restorations. In a recent study, Heintze67  found that both macrotensile and microtensile bond strength tests correlated better with clinical retention of cervical restorations than macroshear and microshear testing. He recommended shear testing to be abandoned due to critical and inadequate stress distribution and unreliable correlation to clinical outcome. Because no universal agreement exists on bonding methods, these authors decided after preliminary investigation to use microtensile strength testing.

For this investigation an easier and much less time-consuming method was developed to measure the tensile bond strength, where straight alignment of the specimen rods glued into commercially available and inexpensive extension screws was obtained. The specimen/extension screw assembly, screwed to the aligned steel wires attached to the testing machine, directed the pulling force longitudinally from the ends of the specimen. Under these testing conditions a vast majority of specimen rods broke in the repair junction. In preliminary testing of the methods and materials used in this study, one flat side of the specimen was glued directly to the jig of the testing machine, resulting in cohesive fractures much more often than when the extension-screw setup was tested. This was attributed to the possibility that the forces might have been less uniformly distributed throughout the specimen than in the new method.68  In all the other comparable investigations19,22,25,43,69  on repair, where microtensile testing was used, cohesive failure is reported as very high, up to 95%. The number of cohesive fractures reported in some of these studies is surprising, because it could be anticipated that the adhesive joint would be the weakest link. If the cohesive fractures are relatively few, as in this study, the results more likely demonstrate the true repair strength of the adhesive joint between the old and the new composites. In general, more cohesive fractures can be expected as the repair strength approaches the fracture strength of the composite used, as observed in this study. However, when the repair strength measured is only half the cohesive strength of the composite used, and two-thirds of the fractures are reported as cohesive, the testing procedure must be questioned.19 

When the three bonding systems tested in this study are compared separately within each surface treatment group, it is obvious that Adper Scotchbond Multi-Purpose, the three-step adhesive, gave the lowest repair microtensile bond strength.

The three-step adhesives have been classified as the criterion standard in adhesive technology when placing resin composite restorations, especially large posterior restorations in load-bearing areas.70-72  The great success this group of materials has experienced is possibly because the relatively thick and more flexible adhesive layer serves as a shock absorber between tooth and composite when the restoration is under masticatory stresses.53,56  Another explanation could be that it contains less hydrophilic monomers than the more acidic self-etching adhesives. High hydrophilicity of an adhesive system may impair the long-term durability of the adhesive, because hydrophilic monomers tend to absorb more water, in time weakening the bond.16,26  One study43  on repair of composites reported early signs of degradation for hydrophilic self-etching adhesive repair bond compared with a hydrophobic three-step adhesive at six months. In most studies24-48  the specimens are tested immediately or a few weeks after the composite repair, and no studies23,43  could be found with storage periods exceeding six months. In this study the specimens were tested after one and 12 months of storage in water in addition to thermocycling. Between the testing periods, a general reduction in mean tensile strength values, 16% to 22%, was observed for all the repaired groups (Table 4). These differences, however, were not statistically significant. A slight reduction, 8.9%, was also observed for the control composite specimens between the storage periods.

When gluing hard pieces together it is of utmost importance to wet both surfaces with the appropriate glue and bring the pieces as tightly together as possible. Evaluating the results and mode of failure from this study, it is postulated that the adhesive film thickness plays a role when repairing resin composite with resin composite. The components in the Clearfil system are considerably more fluid than those in the AdheSE One and the Adper Scotchbond Multi-Purpose adhesives, therefore producing a thinner adhesive layer. Almost all the Adper Scotchbond Multi-Purpose and the AdheSE One specimens failed in the adhesive layer, and many specimens showed adhesive material on both the repaired and the new composite, indicating that the tensile strength of the adhesive itself directed the repair tensile strength at failure. In the Clearfil specimens, the fracture appeared to occur more between the old composite and the adhesive, except for group 3b, the silane-Clearfil group that showed the strongest mean repair bond, which had almost 92% of the mean cohesive strength of the control composite at one month and more than 83% at 12 months. There the fracture often appeared both between the old and the new composite and the adhesive in the same specimen. Coelho and others56  observed lower microtensile bond strength values for Single Bond (3M ESPE) as the adhesive layer between dentin and composite was increased from one layer to three layers; whereas, no correlation could be found for the more fluid Clearfil SE (Kuraray). In that investigation, however, the majority of specimens for both adhesive systems presented mixed cohesive/adhesive failure mode.56 

In this investigation three surface treatments of the aged composite were used. The purpose of a surface treatment is to increase the surface energy and/or the surface roughness. A common practice for mechanical roughening of composite specimens is to use silicon carbide sandpaper with a specific grit, giving a standardized surface roughening. Use of 320-grit sandpaper has been selected by several investigators,23,69,73  the same grit selected for this study. Both of the other two surface treatments added sandblasting the surface with CoJet silica-coated alumina particles or silane application to the 320-grit sandpaper roughening, which significantly improved the mean bond strength (p<0.05), except for group 2b at 12 months. The CoJet particles are designed to penetrate and be embedded in the surface of the substrate and leave it partially coated with silica.74  It is possible that the embedded particles act as microretention for the new composite, explaining the improved bond strength. Sandblasting using alumina particles has also been reported to improve repair bond strength.25,43  In one study22  no difference was found between sandblasting with aluminum oxide and silica coating with CoJet. It was postulated that similar surface roughness pattern resulted in similar mechanical retention.

It is a known fact that silane bonds well to silica-based materials and also to resin composites. Many resin composites contain filler materials that consist of siliceous compounds. This can explain why silanization of old composite improves bonding to new composite as demonstrated in this study. Some studies22,28,43  are, however, in disagreement with our findings. One-bottle prehydrolyzed silane solutions have a relatively short shelf life and gradually become less reactive after opening of the bottle, preventing optimal adhesion.74  In this study a freshly mixed (two-bottle) silane system was used. The two solutions are mixed just before use to allow hydrolysis of the silane to secure a fresh reactive solution. Lundvall and others75  found a much higher bond strength when repairing porcelain with composite using two-bottle silane, whereas one-bottle silane showed similar bond strength as the group without silane.

Using air abrasion in the mouth requires an intraoral sandblaster and it can be difficult to achieve in the dental operatory. Using silane as an adhesion promoter is a simple method that requires no extra equipment and, according to this study, achieves comparable or better results. Within the limitations of this study, a two-bottle silane adhesion promoter in addition to a thin layer of adhesive would be the treatment of choice when repairing resin composite.

The results obtained did not support the three null hypotheses that were claimed. The best repair bond was achieved by using freshly mixed silane solution in addition to an adhesive rendering a thin bonding layer.

The expert assistance of Mr Erik Kleven, Nordic Institute of Dental Materials, for help in designing the microtensile testing procedure and of Dr Michael A. Cochran for editorial assistance is greatly acknowledged.

The authors of this manuscript certify that they have no proprietary, financial, or other personal interest of any nature or kind in any product, service, and/or company that is presented in this article.

1
Mjor
IA
(
1997
)
The reasons for replacement and the age of failed restorations in general dental practice
Acta Odontologica Scandinavica
55
(
1
)
58
-
63
.
2
Mjor
IA
,
&
Gordan
VV
(
2002
)
Failure, repair, refurbishing and longevity of restorations
Operative Dentistry
27
(
5
)
528
-
534
.
3
Mjor
IA
,
Shen
C
,
Eliasson
ST
,
&
Richter
S
(
2002
)
Placement and replacement of restorations in general dental practice in Iceland
Operative Dentistry
27
(
2
)
117
-
123
.
4
Tyas
MJ
,
Anusavice
KJ
,
Frencken
JE
,
&
Mount
GJ
(
2000
)
Minimal intervention dentistry—A review FDI Commission Project 1-97
International Dental Journal
50
(
1
)
1
-
12
.
5
Krejci
I
,
Lieber
CM
,
&
Lutz
F
(
1995
)
Time required to remove totally bonded tooth-colored posterior restorations and related tooth substance loss
.
Dental Materials
11
(
1
)
34
-
40
.
6
Gordan
VV
,
Riley
JL
,
Worley
DC
,
&
Gilbert
GH
(
2012
)
Restorative material and other tooth-specific variables associated with the decision to repair or replace defective restorations: Findings from The Dental PBRN
Journal of Dentistry
40
(
5
)
397
-
405
.
7
Mjor
IA
(
1993
)
Repair versus replacement of failed restorations
International Dental Journal
43
(
5
)
466
-
472
.
8
Blum
IR
,
Lynch
CD
,
Schriver
A
,
Heidemann
D
,
&
Wilson
NH
(
2011
)
Repair versus replacement of defective composite restorations in dental schools in Germany
European Journal of Prosthodontics and Restorative Dentistry
19
(
2
)
56
-
61
.
9
Lynch
CD
,
Blum
IR
,
Frazier
KB
,
Haisch
LD
,
&
Wilson
NH
(
2012
)
Repair or replacement of defective direct resin-based composite restorations: Contemporary teaching in U.S. and Canadian dental schools
Journal of the American Dental Association
143
(
2
)
157
-
163
.
10
Blum
IR
,
Lynch
CD
,
&
Wilson
NH
(
2012
)
Teaching of the repair of defective composite restorations in Scandinavian dental schools
Journal of Oral Rehabilitation
39
(
3
)
210
-
216
.
11
Blum
IR
,
Lynch
CD
,
&
Wilson
NH
(
2012
)
Teaching of direct composite restoration repair in undergraduate dental schools in the United Kingdom and Ireland
European Journal of Dental Education
16
(
1
)
e53
-
e58
.
12
Gordan
VV
,
Mjor
IA
,
Blum
IR
,
&
Wilson
NH
(
2003
)
Teaching students the repair of resin-based composite restorations: A survey of North American dental schools
Journal of the American Dental Association
134
(
3
)
317
-
323
,
quiz 338-339
.
13
Gordan
VV
,
Riley
JL
,
Blaser
PK
,
&
Mjor
IA
(
2006
)
2-year clinical evaluation of alternative treatments to replacement of defective amalgam restorations
Operative Dentistry
31
(
4
)
418
-
425
.
14
Boyer
DB
,
Chan
KC
,
&
Torney
DL
(
1978
)
The strength of multilayer and repaired composite resin
Journal of Prosthetic Dentistry
39
(
1
)
63
-
67
.
15
Brosh
T
,
Baharav
H
,
Gross
O
,
&
Laufer
BZ
(
1997
)
The influence of surface loading and irradiation time during curing on mechanical properties of a composite
Journal of Prosthetic Dentistry
77
(
6
)
573
-
577
.
16
Malacarne
J
,
Carvalho
RM
,
de Goes
MF
,
Svizero
N
,
Pashley
DH
,
Tay
FR
,
Yiu
CK
,
&
Carrilho
MR
(
2006
)
Water sorption/solubility of dental adhesive resins
Dental Materials
22
(
10
)
973
-
980
.
17
Lagouvardos
PE
,
Pissis
P
,
Kyritsis
A
,
&
Daoukaki
D
(
2003
)
Water sorption and water-induced molecular mobility in dental composite resins
Journal of Materials Science: Materials in Medicine
14
(
9
)
753
-
759
.
18
Tarumi
H
,
Torii
M
,
&
Tsuchitani
Y
(
1995
)
Relationship between particle size of barium glass filler and water sorption of light-cured composite resin
Dental Materials Journal
14
(
1
)
37
-
44
.
19
Maneenut
C
,
Sakoolnamarka
R
,
&
Tyas
MJ
(
2011
)
The repair potential of resin composite materials
Dental Materials
27
(
2
)
e20
-
e27
.
20
da Costa
TR
,
Serrano
AM
,
Atman
AP
,
Loguercio
AD
,
&
Reis
A
(
2012
)
Durability of composite repair using different surface treatments
Journal of Dentistry
40
(
6
)
513
-
521
.
21
Dall'oca
S
,
Papacchini
F
,
Radovic
I
,
Polimeni
A
,
&
Ferrari
M
(
2008
)
Repair potential of a laboratory-processed nano-hybrid resin composite
Journal of Oral Science
50
(
4
)
403
-
412
.
22
Rodrigues
SA
Jr,
Ferracane
JL
,
&
Della Bona
A
(
2009
)
Influence of surface treatments on the bond strength of repaired resin composite restorative materials
Dental Materials
25
(
4
)
442
-
451
.
23
Staxrud
F
,
&
Dahl
JE
(
2011
)
Role of bonding agents in the repair of composite resin restorations
European Journal of Oral Science
119
(
4
)
316
-
322
.
24
Costa
TR
,
Ferreira
SQ
,
Klein-Junior
CA
,
Loguercio
AD
,
&
Reis
A
(
2010
)
Durability of surface treatments and intermediate agents used for repair of a polished composite
Operative Dentistry
35
(
2
)
231
-
237
.
25
Loomans
BA
,
Cardoso
MV
,
Roeters
FJ
,
Opdam
NJ
,
De Munch
J
,
Huysmans
MC
,
&
Van Meerbeek
B
(
2011
)
Is there one optimal repair technique for all composites?
Dental Materials
27
(
7
)
701
-
709
.
26
Papacchini
F
,
Toledano
M
,
Monticelli
F
,
Osorio
R
,
Radovic
I
,
Polimeni
A
,
Garcia-Godoy
F
,
&
Ferrari
M
(
2007
)
Hydrolytic stability of composite repair bond
European Journal of Oral Science
115
(
5
)
417
-
424
.
27
Passos
SP
,
Ozcan
M
,
Vanderlei
AD
,
Leite
FP
,
Kimpara
ET
,
&
Bottino
MA
(
2007
)
Bond strength durability of direct and indirect composite systems following surface conditioning for repair
Journal of Adhesive Dentistry
9
(
5
)
443
-
447
.
28
Bonstein
T
,
Garlapo
D
,
Donarummo
J
Jr,
&
Bush
PJ
(
2005
)
Evaluation of varied repair protocols applied to aged composite resin
Journal of Adhesive Dentistry
7
(
1
)
41
-
49
.
29
Cavalcanti
AN
,
De Lima
AF
,
Peris
AR
,
Mitsui
FH
,
&
Marchi
GM
(
2007
)
Effect of surface treatments and bonding agents on the bond strength of repaired composites
Journal of Esthetic and Restorative Dentistry
19
(
2
)
90
-
98
,
discussion 99
.
30
Rathke
A
,
Tymina
Y
,
&
Haller
B
(
2009
)
Effect of different surface treatments on the composite-composite repair bond strength
Clinical Oral Investigations
13
(
3
)
317
-
323
.
31
Yesilyurt
C
,
Kusgoz
A
,
Bayram
M
,
&
Ulker
M
(
2009
)
Initial repair bond strength of a nano-filled hybrid resin: Effect of surface treatments and bonding agents
Journal of Esthetic and Restorative Dentistry
21
(
4
)
251
-
260
.
32
Padipatvuthikul
P
,
&
Mair
LH
(
2007
)
Bonding of composite to water aged composite with surface treatments
Dental Materials
23
(
4
)
519
-
525
.
33
Papacchini
F
,
Dall'Oca
S
,
Chieffi
N
,
Goracci
C
,
Sadek
FT
,
Suh
BI
,
Tay
FR
,
&
Ferrari
M
(
2007
)
Composite-to-composite microtensile bond strength in the repair of a microfilled hybrid resin: Effect of surface treatment and oxygen inhibition
Journal of Adhesive Dentistry
9
(
1
)
25
-
31
.
34
Papacchini
F
,
Magni
E
,
Radovic
I
,
Mazzitelli
C
,
Monticellia
F
,
Goracci
C
,
Polimeni
A
,
&
Ferrari
M
(
2007
)
Effect of intermediate agents and pre-heating of repairing resin on composite-repair bonds
Operative Dentistry
32
(
4
)
363
-
371
.
35
Papacchini
F
,
Monticelli
F
,
Radovic
I
,
Chieffi
N
,
Goracci
C
,
Tay
FR
,
Polimeni
A
,
&
Ferrari
M
(
2007
)
The application of hydrogen peroxide in composite repair
Journal of Biomedical Materials Research Part B: Applied Biomaterials
82
(
2
)
298
-
304
.
36
Papacchini
F
,
Radovic
I
,
Magni
E
,
Goracci
C
,
Monticelli
F
,
Chieffi
N
,
Polimeni
A
,
&
Ferrari
M
(
2008
)
Flowable composites as intermediate agents without adhesive application in resin composite repair
American Journal of Dentistry
21
(
1
)
53
-
58
.
37
Kupiec
KA
,
&
Barkmeier
WW
(
1996
)
Laboratory evaluation of surface treatments for composite repair
Operative Dentistry
21
(
2
)
59
-
62
.
38
Shahdad
SA
,
&
Kennedy
JG
(
1998
)
Bond strength of repaired anterior composite resins: an in vitro study
Journal of Dentistry
26
(
8
)
685
-
694
.
39
Yap
AU
,
Quek
CE
,
&
Kau
CH
(
1998
)
Repair of new-generation tooth-colored restoratives: Methods of surface conditioning to achieve bonding
Operative Dentistry
23
(
4
)
173
-
178
.
40
Yap
AU
,
Sau
CW
,
&
Lye
KW
(
1999
)
Effects of aging on repair bond strengths of a polyacid-modified composite resin
Operative Dentistry
24
(
6
)
371
-
376
.
41
Lucena-Martin
C
,
Gonzalez-Lopez
S
,
&
Navajas-Rodriguez de Mondelo
JM
(
2001
)
The effect of various surface treatments and bonding agents on the repaired strength of heat-treated composites
Journal of Prosthetic Dentistry
86
(
5
)
481
-
488
.
42
Oztas
N
,
Alacam
A
,
&
Bardakcy
Y
(
2003
)
The effect of air abrasion with two new bonding agents on composite repair
Operative Dentistry
28
(
2
)
149
-
154
.
43
da Costa
TRF
,
Serrano
AM
,
Atman
AP
,
Loguercio
AD
,
&
Reis
A
(
2012
)
Durability of composite repair using different surface treatments
Journal of Dentistry
40
(
6
)
513
-
521
.
44
Loomans
BAC
,
Cardoso
MV
,
Opdam
NJ
,
Roeters
FJ
,
De Munck
J
,
Huismans
MC
,
&
Van Meerbeek
B
(
2011
)
Surface roughness of etched composite resin in light of composite repair
Journal of Dentistry
39
(
7
)
499
-
505
.
45
Trajtenberg
CP
,
&
Powers
JM
(
2004
)
Effect of hydrofluoric acid on repair bond strength of a laboratory composite
American Journal of Dentistry
17
(
3
)
173
-
176
.
46
Brendeke
J
,
&
Ozcan
M
(
2007
)
Effect of physicochemical aging conditions on the composite-composite repair bond strength
Journal of Adhesive Dentistry
9
(
4
)
399
-
406
.
47
Fawzy
AS
,
El-Askary
FS
,
&
Amer
MA
(
2008
)
Effect of surface treatments on the tensile bond strength of repaired water-aged anterior restorative micro-fine hybrid resin composite
Journal of Dentistry
36
(
12
)
969
-
976
.
48
Özcan
M
,
Barbosa
SH
,
Melo
RM
,
Galhano
GA
,
&
Bottino
MA
(
2007
)
Effect of surface conditioning methods on the microtensile bond strength of resin composite to composite after aging conditions
Dental Materials
23
(
10
)
1276
-
1282
.
49
Hamano
N
,
Chiang
YC
,
Nyamaa
I
,
Yamaguchi
H
,
Ino
S
,
Hickel
R
,
&
Kunzelmann
KH
(
2012
)
Repair of silorane-based dental composites: Influence of surface treatments
Dental Materials
28
(
8
)
894
-
902
.
50
Wiegand
A
,
Stawarczyk
B
,
Buchalla
W
,
Taubock
TT
,
Ozcan
M
,
&
Attin
T
(
2012
)
Repair of silorane composite—Using the same substrate or a methacrylate-based composite?
Dental Materials
28
(
3
)
e19
-
e25
.
51
Ivanovas
S
,
Hickel
R
,
&
Ilie
N
(
2011
)
How to repair fillings made by silorane-based composites
Clinical Oral Investigations
15
(
6
)
915
-
922
.
52
Giachetti
L
,
Russo
DS
,
Baldini
M
,
Goracci
C
,
&
Ferrari
M
(
2012
)
Reparability of aged silorane with methacrylate-based resin composite: Micro-shear bond strength and scanning electron microscopy evaluation
Operative Dentistry
37
(
1
)
28
-
36
.
53
Kemp-Scholte
CM
,
&
Davidson
CL
(
1990
)
Complete marginal seal of class V resin composite restorations effected by increased flexibility
Journal of Dental Research
69
(
6
)
1240
-
1243
.
54
Knight
GT
,
&
Berry
TG
(
1997
)
Clinical application of a direct placement mercury-free alloy
American Journal of Dentistry
10
(
1
)
52
-
54
.
55
Tam
LE
,
Khoshand
S
,
&
Pilliar
RM
(
2001
)
Fracture resistance of dentin-composite interfaces using different adhesive resin layers
Journal of Dentistry
29
(
3
)
217
-
225
.
56
Coelho
PG
,
Calamia
C
,
Harsono
M
,
Thompson
VP
,
&
Silva
NR
(
2008
)
Laboratory and FEA evaluation of dentin-to-composite bonding as a function adhesive layer thickness
Dental Materials
24
(
10
)
1297
-
1303
.
57
Kalachandra
S
(
1989
)
Influence of fillers on the water sorption of composites
Dental Materials
5
(
4
)
283
-
288
.
58
Press
WP
,
Flannery
BP
,
Teukolsky
SA
,
&
Vetterling
WT
(
1986
)
Kolmogorov-Smirnov test
In
:
Numerical Recipes: The Art of Scientific Computing
Cambridge University Press
,
Cambridge
472
-
475
.
59
Van Noort
R
,
Noroozi
S
,
Howard
IC
,
&
Cardew
G
(
1989
)
A critique of bond strength measurements
Journal of Dentistry
17
(
2
)
61
-
67
.
60
Della Bona
A
,
&
van Noort
R
(
1995
)
Shear vs. tensile bond strength of resin composite bonded to ceramic
Journal of Dental Research
74
(
9
)
1591
-
1596
.
61
Scherrer
SS
,
Cesar
PF
,
&
Swain
MV
(
2010
)
Direct comparison of the bond strength results of the different test methods: A critical literature review
Dental Materials
26
(
2
)
E78
-
E93
.
62
Pashley
DH
,
Carvalho
RM
,
Sano
H
,
Nakajima
M
,
Yoshiyama
M
,
Shono
Y
,
Fernandes
CA
,
&
Tay
F
(
1999
)
The microtensile bond test: A review
Journal of Adhesive Dentistry
1
(
4
)
299
-
309
.
63
Poitevin
A
,
De Munck
J
,
Van Landuyt
K
,
Coutinho
E
,
Peumans
M
,
Lambrechts
P
,
&
Van Meerbeek
B
(
2008
)
Critical analysis of the influence of different parameters on the microtensile bond strength of adhesives to dentin
Journal of Adhesive Dentistry
10
(
1
)
7
-
16
.
64
McDonough
WG
,
Antonucci
JM
,
He
J
,
Shimada
Y
,
Chiang
MY
,
Schumacher
GE
,
&
Schultheisz
CR
(
2002
)
A microshear test to measure bond strengths of dentin-polymer interfaces
Biomaterials
23
(
17
)
3603
-
3608
.
65
Foong
J
,
Lee
K
,
Nguyen
C
,
Tang
G
,
Austin
D
,
Ch'ng
C
,
Burrow
MF
,
&
Thomas
DL
(
2006
)
Comparison of microshear bond strengths of four self-etching bonding systems to enamel using two test methods
Australian Dental Journal
51
(
3
)
252
-
257
.
66
Van Meerbeek
B
,
Peumans
M
,
Poitevin
A
,
Mine
A
,
Van Ende
A
,
Neves
A
,
&
De Munck
J
(
2010
)
Relationship between bond-strength tests and clinical outcomes
Dental Materials
26
(
2
)
E100
-
E121
.
67
Heintze
SD
(
2013
)
Clinical relevance of tests on bond strength, microleakage and marginal adaptation
Dental Materials
29
(
1
)
59
-
84
.
68
El Zohairy
AA
,
de Gee
AJ
,
de Jager
N
,
van Ruijven
LJ
,
&
Feilzer
AJ
(
2004
)
The influence of specimen attachment and dimension on microtensile strength
Journal of Dental Research
83
(
5
)
420
-
424
.
69
Hamano
N
,
Chiang
YC
,
Nyamaa
I
,
Yamaguchi
H
,
Ino
S
,
Hickel
R
,
&
Kunzelmann
KH
(
2012
)
Repair of silorane-based dental composites: Influence of surface treatments
Dental Materials
28
(
8
)
894
-
902
.
70
Van Meerbeek
B
,
De Munck
L
,
Yoshida
Y
,
Inoue
S
,
Vargas
M
,
Vijay
P
,
Van Landuyt
K
,
Lambrechts
P
,
&
Vanherle
G
(
2003
)
Buonocore Memorial Lecture: Adhesion to enamel and dentin: Current status and future challenges
Operative Dentistry
28
(
3
)
215
-
235
.
71
Perdigao
J
(
2007
)
New developments in dental adhesion
Dental Clinics of North America
51
(
2
)
333
-
357
,
viii
.
72
Manuja
N
,
Nagpal
R
,
&
Pandit
IK
(
2012
)
Dental adhesion: Mechanism, techniques and durability
Journal of Clinical Pediatric Dentistry
36
(
3
)
223
-
234
.
73
Tezvergil
A
,
Lassila
LVJ
,
&
Vallittu
PK
(
2003
)
Composite-composite repair bond strength: Effect of different adhesion primers
Journal of Dentistry
31
(
8
)
521
-
525
.
74
Lung
CYK
,
&
Matinlinna
JP
(
2012
)
Aspects of silane coupling agents and surface conditioning in dentistry: An overview
.
Dental Materials
28
(
5
)
467
-
477
.
75
Lundvall
PK
,
Ruyter
E
,
Ronold
HJ
,
&
Ekstrand
K
(
2009
)
Comparison of different etching agents and repair materials used on feldspathic porcelain
Journal of Adhesion Science and Technology
23
(
7-8
)
1177
-
1186
.