Clinical Relevance

Shortened light curing does not affect volumetric polymerization shrinkage or cohesive tensile strength but negatively affects the shear bond strength of some bulk-fill resin composites. When performing shortened light curing, clinicians should be aware of the light output of their light-curing units.

SUMMARY

Purpose: To evaluate volumetric polymerization shrinkage (VPS), shear bond strength (SBS) to dentin, and cohesive tensile strength (CTS) of bulk-fill resin composites (BFRCs) light activated by different modes.

Methods and Materials: Six groups were evaluated: Tetric EvoCeram bulk fill + high mode (10 seconds; TEC H10), Tetric EvoFlow bulk fill + high mode (TEF H10), experimental bulk fill + high mode (TEE H10), Tetric EvoCeram bulk fill + turbo mode (five seconds; TEC T5), Tetric EvoFlow bulk fill + turbo mode (TEF T5), and experimental bulk fill + turbo mode (TEE T5). Bluephase Style 20i and Adhese Universal Vivapen were used for all groups. All BFRC samples were built up on human molar bur-prepared occlusal cavities. VPS% and location were evaluated through micro–computed tomography. SBS and CTS tests were performed 24 hours after storage or after 5000 thermal cycles; fracture mode was analyzed for SBS.

Results: Both TEC H10 and TEE H10 presented lower VPS% than TEF H10. However, no significant differences were observed with the turbo-curing mode. No differences were observed for the same BFRC within curing modes. Occlusal shrinkage was mostly observed. Regarding SBS, thermal cycling (TC) affected all groups. Without TC, all groups showed higher SBS values for high mode than turbo mode, while with TC, only TEC showed decreased SBS from high mode to turbo modes; modes of fracture were predominantly adhesive. For CTS, TC affected all groups except TEE H10. In general, no differences were observed between groups when comparing the curing modes.

Conclusions: Increased light output with a shortened curing time did not jeopardize the VPS and SBS properties of the BFRCs, although a decreased SBS was observed in some groups. TEE generally showed similar or improved values for the tested properties in a shortened light-curing time. The VPS was mostly affected by the materials tested, whereas the SBS was affected by the materials, curing modes, and TC. The CTS was not affected by the curing modes.

In current practice, there is hardly a dental procedure that does not require the use of a polymeric resin material and light activation.1  Resin composite restorations present good esthetic and mechanical properties as well as adhesion to the tooth structure using an adhesive system; however, the time spent on performing these procedures is a drawback.2  For that reason, and as a matter of improving clinical efficiency, bulk-fill resin composites (BFRCs) were introduced in the market, and numerous in vitro studies have evaluated these restorative materials.317  BFRCs present modifications in their compositions, such as new monomers and changes in their concentrations, addition of new photoinitiators, increased translucency, and decreased or changes in their inorganic content. All of these modifications have allowed them to be applied in a 4- to 5-mm thicknesses, thus diminishing the time spent on the restorative procedure.16  Moreover, they are presented in two different formulations with high and low viscosity; the latter requires a capping layer of regular resin composite for finishing the restoration because of its weak mechanical properties,5,12  which compromises the time-saving benefit by adding an extra step.10 

Most of the published literature suggests that BFRCs have good performance in terms of degree of conversion,13,14  polymerization shrinkage,3,15  and bonding properties.8  Although BFRCs are a faster procedure compared with the incremental technique, clinicians still aim to save more time. Thus, there has recently been a move toward an even faster light activation of BFRCs.18  Such time-saving procedures should not be detrimental to the material’s mechanical properties, because adequate light curing is required for resin composite restorations to reach their manufacturer’s intended properties and ensure predictable long-term clinical success.1  It seems logical that if a restoration does not receive sufficient incident irradiance, mostly for a 4-mm-depth BFRC restoration, it will not reach its ideal mechanical and bonding properties to the teeth,1  which could lead to bulk fracture of the restoration, secondary caries due to adhesive failure, and breakdown of the margin. 19,20 

The third-generation light-emitting diode (LED) light-curing units (LCUs), also called “polywave,” provide a broad-spectrum LCU that can activate all current photoinitiators present in resin composites. 18  The need for such LCUs is because different photoinitiators, apart from the conventional camphorquinone (light activated within the blue range, about 460–470 nm), are being used in formulations of resin composites. These are type I photoinitiators, and need another range of delivered light.18  Such photoinitiators (eg, Lucirin TPO and derivatives of dibenzoyl germanium such as Ivocerin) do not need additional co-initiators, as they decompose directly into 1 or more free radicals when sufficient energy at the correct wavelength is delivered.18 

Ivocerin is most reactive at 408 nm but remains very sensitive to wavelengths of light between 400 and 430 nm. It is considered an “initiation booster” because of its ability to start the reaction with fewer photons, polymerize deeply, and regulate polymerization during curing of a material in bulk.21  Also, the greater ability of these materials to create free radicals per molecule unit can improve the light sensitivity of resin composites.22  Thus, depending on the photoinitiators used, even small changes in the emission spectrum (wavelength) can be relevant.18  Apart from the wavelength needed, the irradiance is also an important factor when light curing a resin composite.18  The introduction of LED LCUs with high power and short exposure has raised concerns regarding effectiveness, to ensure that the restoration is not undercured.7,22,23 

One of the most investigated properties of BFRCs is polymerization shrinkage,3,4,15  an unavoidable phenomenon that occurs because of the polymerization reaction of all resinous materials when the monomers are converted to polymers. Its undesirable clinical outcomes include shrinkage stress on the tooth-restoration interface, which can form gaps at the interface, and marginal infiltration.3,15  Volumetric polymerization shrinkage (VPS) can be observed through a nondestructive, three-dimensional, highresolution imaging technique test called micro–computed tomography (μCT),3,4,15  which has been used for different purposes, such as evaluating cementation film thickness,24  presence of bubbles with different cementation techniques,25  and polymerization shrinkage vectors.26 

Mechanical properties5,6,12  play a fundamental role in the clinical performance of a restorative material. It can be evaluated through a great number of tests, such as degree of conversion, hardness, and tensile tests.8,14,27  As stated in a recent study, it is likely that most dental restorations fail by tensile stresses set up within their structure because of the loading mechanism of their complex geometries.27 

The bonding to the tooth structure is also an important parameter that needs attention when dealing with BFRCs, as the light beam from the LCU decreases with distance.8  Thus, the interface between the resin composite and tooth, which is where the adhesive system is located, is a critical spot, as it is the one farther away from the LCU’s light tip. A reduction in the bond strength to dentin at the bottom of the cavity in class I restorations with BFRCs has been shown in the literature.17 

Aiming to mimic the degradation of the oral environment, TC is an effective in vitro aging protocol, performed to create thermal strains at the bonding interface caused by thermal changes in water baths. Moreover, repetition of such baths were shown to weaken the bond between the resin matrix and filling material.28 

Thus, the aim of the present study is to determine the influence of different light-curing modes (high mode and turbo mode) of a single LCU on the VPS, shear bond strength (SBS) to dentin, and cohesive tensile strength (CTS) of two commercial and one experimental BFRC. The hypotheses tested were the following: 1) different light-curing modes would affect the VPS, SBS, and CTS of different BFRCs, and 2) within a given BFRC, there would be significant differences regarding VPS, SBS, and CTS light activated with different curing modes.

Material composition, manufacturers, and batch numbers are described in Table 1. Three different BFRCs were used: Tetric EvoCeram bulk fill (TEC; Ivoclar Vivadent, Schaan, Liechtenstein), Tetric EvoFlow bulk fill (TEF; Ivoclar Vivadent), and an experimental BFRC containing double the Ivocerin photoinitiator than its counterpart TEC (Tetric EvoCeram Experimental bulk fill [TEE]; Ivoclar Vivadent). All materials were light activated by the same LCU (Bluephase Style 20i, Ivoclar Vivadent) at two different curing modes: high mode for 10 seconds (H10; approximately 1200 mW/cm2) and turbo mode for five seconds (T5; approximately 2000 mW/cm2). Power outputs of the LCU were checked with a Bluephase Meter II (Ivoclar Vivadent) before and after all tests. All teeth used in the present study were obtained according to protocols approved by the New York University Ethical Committee.

Table 1:

Detailed Information of the Bulk-Fill Resin Composites Used in This Study

Detailed Information of the Bulk-Fill Resin Composites Used in This Study
Detailed Information of the Bulk-Fill Resin Composites Used in This Study

Assessment of VPS and the Location

Thirty-six caries-free human third molars had their cusps flattened, and standardized boxed-shaped class I preparations (4-mm depth × 4-mm length × 4-mm width) were made with a diamond bur (AD20 Occlusal reduction bur, code 845-022; Strauss, Westport, CT, USA), which was replaced every five cavity preparations. Final cavity dimensions were checked with a digital caliper, and teeth were maintained in distilled water (25°C) until their use. Teeth were randomly divided into six groups (n=6 per group) according to BFRC and light-curing mode used: G1, TEC H10; G2, TEF H10; G3, TEE H10; G4, TEC T5; G5, TEF T5; and G6, TEE T5. All groups were light activated by the same LCU (Bluephase Style 20i) and used the same adhesive system (Adhese Universal Vivapen, Ivoclar Vivadent), which was light activated according to the same designated time as for the BFRCs. The adhesive system was used in a self-etching procedure, after cleaning the cavities with a pumice slurry. All cavities were filled in the bulk technique.

Each tooth was scanned three times using a μCT apparatus (μCT40, Scanco Medical, AG, Basserdorf, Switzerland), calibrated using a phantom standard at 70 kVp/BH 200 mgHA/cm. The operating condition for the μCT device used was 70 kVp to 114 microamperes with a resolution of 16 μm/slice. The average of the total number of slices was approximately 250, and the average scan time was 28 minutes, as previously described.3,15 

The first scan was performed after cavity preparation. This procedure was required for avoiding scattering and possible noise between the restorative material and the tooth structure but also to minimize possible artifacts in the threshold segmentation, because enamel, dentin, and restorative material present similar radiodensity.3,4,15  The second scan was performed after application of the adhesive system and resin composite and before the light-curing procedure (uncured scan); the third scan was done after light curing the samples (cured scan). During the scans, all samples were kept in a dark vial to prevent any contact with a light source for unwanted polymerization.

Acquired μCT data were imported into a workstation and evaluated with Amira software (version 5.5.2, VSG, Burlington, MA, USA). All scans were superimposed with the Amira software tool called “superimposition,” providing a perfect arrangement of all images. Registered μCT data of uncured and cured samples were subtracted from the cavity data, isolating the restoration (uncured scan minus cavity preparation scan, and cured scan minus cavity preparation scan). This procedure enabled both uncured and cured resin composite volumes to be isolated and quantified, allowing the total VPS to be calculated as a percentage. Shrinkage observed on the top and bottom/sides of the cavity were also evaluated; for that purpose, separation within the top and bottom/sides locations was evaluated with the Amira tool called “extract surface” and measured separately, also calculated as percentages. Location data were presented regarding the top surface, and the rest of the shrinkage was considered as bottom/sides.

Data regarding total VPS measurement and VPS in the different locations from the cavity (top and bottom/sides) were analyzed by a normality test followed by a two-way analysis of variance (ANOVA) and least significant difference (LSD) post hoc tests using 95% confidence intervals.

Assessment of SBS With and Without Thermal Cycling

One hundred twenty caries-free human third molars had their roots removed and crowns sectioned with a low-speed diamond disk saw under water cooling to expose mid-coronal dentin. Exposed surfaces were abraded in a semiautomatic polishing machine (LaboPol-6, Struers, Madrid, Spain) with 500-grit silicon carbide abrasive paper under water cooling, in order to standardize the smear layer. Groups were divided as previously described: G1, TEC H10; G2, TEF H10; G3, TEE H10; G4, TEC T5; G5, TEF T5; and G6, TEE T5. All groups were light activated by the same LCU (Bluephase Style 20i) and the same adhesive system (Adhese Universal Vivapen, Ivoclar Vivadent), which was light activated according to the same designated time as for the resin BFRCs. The adhesive system was used in a self-etching procedure, after cleaning the cavities with a pumice slurry.

The BFRC was built up in bulk through a disc with a central orifice (Ø=3.0 mm and 4-mm high), which was centered on the occlusal tooth surface to obtain the standardized resin composite bar for the SBS test. All resin blocks were prepared in a single increment.

After the restorative procedures, samples were subdivided in two subgroups (n=10): 1) storage in distilled water at 37°C for 24 hours or 2) 5000 thermal cycles in water baths for 30 seconds in each bath of 5°C and 55°C in a thermal cycling (TC) simulator machine.

After the designated storage period, each sample was placed in an SBS testing machine (Shear Bond Tester, Bisco Dental, Schaumburg, IL, USA), and SBS was measured at a cross-head speed of 1 mm/min. The maximum load of SBS of the composite resin to dentin was recorded in newtons (N) and calculated in MPa, taking into account the crosssectional area of the composite buildup. The SBS data were analyzed by normality test, followed by a three-way ANOVA and LSD post hoc tests using 95% confidence intervals.

After SBS testing, the fracture mode of each specimen was determined under a loupe (Panoramic Flip-up Adivista 2.5x; PeriOptix Inc, Lompoc, CA, USA) at 2.5× magnification and classified as 1 = adhesive fracture, 2 = cohesive fracture in dentin, 3 = cohesive fracture in resin composite, 4 = mixed fracture (adhesive + dentin), or 5 = mixed fracture (adhesive + resin composite).

Assessment of CTS With and Without TC

One hundred twenty beam-shaped samples with a cross-sectional area of approximately 1 mm2 were constructed with a silicon matrix. Groups were divided as previously described for the SBS test: G1, TEC H10; G2, TEF H10; G3, TEE H10; G4, TEC T5; G5, TEF T5; and G6, TEE T5. After that, samples were subdivided into two subgroups (n=10): 1) storage in distilled water at 37°C for 24 hours or 2) 5000 thermal cycles in water baths for 30 seconds in each bath of 5°C and 55°C in a TC simulator machine.

After the designated storage period, each beam was individually fixed to a microtensile device with a cyanoacrylate-based glue (Zapit, Dental Ventures of America, Corona, CA, USA) and attached to a universal testing machine (Micro Tensile Tester, Bisco Dental). Specimens were tensile loaded until fracture at a cross-head speed of 1 mm/min. The CTS values were recorded in MPa. Data were analyzed by a normality test, followed by a three-way ANOVA and LSD post hoc tests using 95% confidence intervals.

Table 2 shows the VPS for the different BFRCs and curing modes and also the main location where it occurred. Only the top surface results are described in Table 2, as the rest of the shrinkage was considered as bottom/sides. Figure 1 shows the representative images obtained by the μCT scans. No significant differences in VPS were observed between the high and turbo curing modes for any BFRC (p>0.05). For turbo mode, no statistical differences were observed between the different BFRCs (p>0.05), except for the high curing mode, in which TEF showed statistically higher VPS% than both TEC (p=0.032) and TEE (p=0.036). For all BFRCs and curing modes, most of the VPS occurred at the top, the unbonded portion, of the restoration (p<0.05). Regarding the different curing modes within the same material, no statistical differences were observed in shrinkage location within the curing modes for any BFRC (p>0.05). However, when the same curing mode was evaluated comparing different BFRCs, for turbo mode, TEE showed statistically less VPS% on top of the restoration than TEC (p=0.001) and TEF (p=0.003). For the high-curing mode, TEF presented statistically the same VPS% on the top of the restoration of TEC (p=0.379) but was statistically different when compared with TEE (p=0.026), whereas TEC and TEE showed statistically similar VPS% on top of the restoration (p=0.156).

Table 2:

Volumetric Polymerization Shrinkage (VPS) of Three Bulk-Fill Resin Composites Tested Under High- and Turbo-Curing Modes a

Volumetric Polymerization Shrinkage (VPS) of Three Bulk-Fill Resin Composites Tested Under High- and Turbo-Curing Modes a
Volumetric Polymerization Shrinkage (VPS) of Three Bulk-Fill Resin Composites Tested Under High- and Turbo-Curing Modes a
Figure 1.

Micro–computed tomography (μCT) scans of three bulk-fill resin composites tested under high (10 seconds) and turbo (five seconds) curing modes. The images show the location of shrinkage in pink (groups TEC H10 and T5), blue (groups TEF H10 and T5), and orange (groups TEE H10 and T5). Observe that the shrinkage was mostly frequent in the occlusal (unbonded surface) for all samples. Images from the left column show the restored teeth, the middle column shows the restoration and shrinkage digitally extracted from the tooth, and the right column shows the shrinkage only.

Figure 1.

Micro–computed tomography (μCT) scans of three bulk-fill resin composites tested under high (10 seconds) and turbo (five seconds) curing modes. The images show the location of shrinkage in pink (groups TEC H10 and T5), blue (groups TEF H10 and T5), and orange (groups TEE H10 and T5). Observe that the shrinkage was mostly frequent in the occlusal (unbonded surface) for all samples. Images from the left column show the restored teeth, the middle column shows the restoration and shrinkage digitally extracted from the tooth, and the right column shows the shrinkage only.

Close modal

Table 3 shows the results from the SBS test for the different BFRCs at each curing mode, with and without TC. For all materials, the high-curing mode presented a higher SBS than turbo-curing mode, in which no TC was performed (p≤0.05). When TC was performed, only the values of TEC decreased statistically from high- to turbo-curing mode (p=0.018), while for the other BFRCs, the values comparing both curing modes showed no significant differences (p>0.05). When comparing the BFRCs with and without TC at the same curing mode, all groups showed a statistically decreased SBS when TC was performed (p≤0.05). When the different BFRCs were compared within the high-curing mode without TC, TEF and TEE showed a statistically similar SBS (p=0.200), and TEF showed an increased SBS when compared with TEC (p=0.035), a pattern that was repeated for turbo-curing mode without TC. When samples were subjected to TC and the different BFRCs were compared with the same curing mode, no statistical differences within the BFRCs were observed for the high-curing mode (p>0.05), while for the turbo-curing mode, the experimental TEE composite showed a statistically higher SBS than the other groups, TEC (p=0.002) and TEF (p=0.007), with no statistical difference between the groups (p=0.578).

Table 3:

Shear Bond Strength (SBS) of Three Bulk-Fill Resin Composites Tested Under High- and Turbo-Curing Modes a

Shear Bond Strength (SBS) of Three Bulk-Fill Resin Composites Tested Under High- and Turbo-Curing Modes a
Shear Bond Strength (SBS) of Three Bulk-Fill Resin Composites Tested Under High- and Turbo-Curing Modes a

The SBS modes of fracture are presented in Table 4. This was predominantly adhesive for TEC H10s and TEC T5s, both with and without TC. Regarding TEF, without TC, for both high mode and turbo mode, the most predominant modes of fracture were adhesive and mixed (adhesive/resin). For samples subjected to TC, fractures were predominantly adhesive for both curing modes. When TEE was analyzed, the predominance of the fracture modes was adhesive for TEE H10s and TEE T5s both with and without TC.

Table 4:

Fracture Mode in the Shear Bond Strength (SBS) of Three Bulk-Fill Resin Composites Tested Under High (H10)–and Turbo (T5)—Curing Modes, With or Without Thermal Cycling (TC)

Fracture Mode in the Shear Bond Strength (SBS) of Three Bulk-Fill Resin Composites Tested Under High (H10)–and Turbo (T5)—Curing Modes, With or Without Thermal Cycling (TC)
Fracture Mode in the Shear Bond Strength (SBS) of Three Bulk-Fill Resin Composites Tested Under High (H10)–and Turbo (T5)—Curing Modes, With or Without Thermal Cycling (TC)

Table 5 shows the results from the CTS test for the different BFRCs at each curing mode, with and without TC. When the same BFRC was compared in different light-curing modes, both with and without TC, no statistical differences were observed (p>0.05). When comparing the BFRCs with and without TC using the same curing mode, all materials showed a statistical decrease in CTS when TC was performed (p<0.05), except for TEE H10, for which the CTS values were statistically similar both with and without TC (p=0.181). When the different BFRCs were compared within the high-curing mode with or without TC, no statistical differences were observed within the BFRCs (p>0.05), while for the turbo-curing mode, TEF presented higher cohesive strength than TEE (p=0.012) when TC was not performed. However, it presented no significant difference compared with TEC (p=0.100). When TC was performed, again, no statistical differences were observed among BFRCs (p>0.05).

Table 5:

Cohesive Tensile Strength (CTS) of Three Bulk-Fill Resin Composites Tested Under High- and Turbo-Curing Modes a

Cohesive Tensile Strength (CTS) of Three Bulk-Fill Resin Composites Tested Under High- and Turbo-Curing Modes a
Cohesive Tensile Strength (CTS) of Three Bulk-Fill Resin Composites Tested Under High- and Turbo-Curing Modes a

The first hypothesis tested was accepted, because different light-curing modes affected the VPS, SBS, and CTS of BFRCs. The second hypothesis tested was also accepted, since different BFRCs promoted significant differences regarding VPS, SBS, and CTS light activated with different curing modes.

The VPS percentages corroborate those of other studies,3,4,15  ranging from 2.3% to 3.0%. The lowviscosity TEF presented higher VPS than the other BFRCs tested for high-curing mode, TEC and TEE, an expected result, as TEF presents fewer inorganic fillers than its high-viscosity counterpart (62wt% and 79–81wt%, respectively). Previous reports showed that composites with lower filler content could result in higher VPS% than high-viscosity ones, because high-viscosity resin composites commonly present reduced monomer content.29  However, no differences within the BFRCs were observed for the turbo mode, which can be explained by the faster polymerization using this light-activation mode, which could have reduced the pre-gel phase, forming short chains before the solid state is reached.29,30  BFRCs did not show a significant difference when the different curing modes were evaluated. This result is in accordance with a recent study4  that evaluated a single BFRC light activated with four different types of curing modes and observed no significant differences within them. However, the present study disagrees with the findings of other studies that showed that a light-curing protocol with lower irradiance and longer exposure time resulted in lower VPS, as slower polymerization forms longer chains with higher molecular weight compared with higher irradiance,5  a phenomenon not observed in the present study.

Regarding shrinkage location, for all groups, top shrinkage was detected more often than bottom/sides shrinkage, an expected result, as a higher VPS% has been demonstrated where there is no adhesive interface (unbonded surface), for instance, the occlusal surface.3,4,15  When the different BFRCs were compared, the experimental BFRC (TEE) showed a lower top (occlusal) VPS% than the other investigated materials and thus more VPS% in the bonded walls. This result could be related to the increased amount of photoinitiator in its composition, which could have resulted in a higher degree of polymerization in deeper regions, thus promoting more VPS in the bottom/sides than the other BFRCs.3,15  Further studies should focus on comparing the VPS% and degree of conversion of resin composites with increased photoinitiators. Thus, according to the present study, with regard to VPS, it was observed that the parameter is mostly affected by the materials used rather than by the curing modes.

The SBS test demonstrated decreased values for all BFRCs with TC. The deterioration of the adhesive interface after thermal aging is in accordance with the literature.31  A recent study observed the deterioration of different universal adhesives, including the one used in this study, and found lower SBS and a less stable marginal sealing capability than in the immediate condition.32  This can be explained by the fact that TC produces hoop stress33  as a result of the unequal thermal expansion of the different substrates compromised in the bonded interface, which could induce volumetric changes in the adhesive layers.34  The SBS results also reflect the fracture modes observed in the present study, predominantly adhesive for all materials with TC, while without TC, TEF was the BFRC that resulted in more samples with a mixed type of fracture, which explains its higher SBS values compared with the other BFRCs. Without TC, all BFRCs tested showed a significant decrease in SBS when turbo mode was used compared with high mode. With TC, only TEC showed significantly decreased values for turbo mode compared with high mode, whereas TEF and TEE materials showed no statistical differences between high and turbo modes. This can be explained by the evidence that the flowable composite has higher translucency before polymerization, and the experimental composite, because of its increased amount of photoinitiator, could cause more stable adhesion with TC. It has been proven that the greater absorption of this photoinitiator also contributes to an increased depth of cure of resin materials.5,21 

When comparing the SBS of the different BFRCs within the same light-curing mode, for both high and turbo modes without TC, TEF and TEE showed the highest results, while TEC and TEE were not significantly different from each other. For the results with TC, the different BFRCs did not show significant between-group differences when using high mode, although for the turbo-curing mode, the experimental material TEE showed higher SBS values than those obtained for TEC and TEF. It was observed in a previous work from this group that the violet light loses its power with increased depths.26  With a higher amount of Ivocerin in the experimental material TEE, deep regions (eg, 4 mm) could have been more polymerized by both emitted lights (blue and violet) from the Bluephase Style 20i. The light activation of the experimental TEE with turbo mode resulted in a lack of significant differences between it and high mode. When this experimental material was evaluated with TC, higher SBS results were obtained using turbo mode compared with the other BFRCs studied.

The CTS values demonstrated no difference in light-curing mode for any of the BFRCs, both with or without TC. Although these results cannot be compared with the findings of any other study, as the CTS of BFRCs has not been investigated so far, they do agree with the VPS% results, as no differences were observed between the light-curing modes. However, significant differences were observed when TC aging was compared, as all BFRCs showed a decrease in CTS values, except for TEE H10. This result was expected, as it is known that thermal aging negatively affects the mechanical properties of resinous materials because of their expansion and shrinkage, which could weaken the bonds that connect the structure of the resin.35  The lack of significant differences when TC was performed or not was observed only for the experimental BFRC; however, no significant differences were observed within the different materials with TC.

It has been shown that longer curing times at lower irradiances improve the mechanical properties of resin composites, and an increased volume of photoinitiator can also positively affect this parameter.29  A significant difference among the different BFRCs was observed only for turbo mode without TC, in which the experimental BFRC TEE presented a lower CTS than the flowable BFRC did. This result was not expected, because this material has a greater amount of inorganic fillers than its flowable version. However, a possible explanation for this result is the increased translucency of the flowable material when compared with high-viscous materials before polymerization,5  which allows more light transmission through the material, possibly improving its mechanical properties. A limitation of this result is that the CTS test was performed in a 1-mm2 beam sample. BFRCs are intended to be cured at up to 4-mm thickness; thus, the size of the sample could be related to the lack of statistically significant differences within the BFRCs.

The use of increased emitted irradiance in a reduced time has been suggested to save time during restorative procedures. However, results from the present study suggest that the use of a reduced curing time should be done with caution, mostly regarding the SBS of BFRCs. Moreover, clinically, light exposure might be jeopardized by the hard access of the LCU in terms of the position of the teeth in the mouth (distance to target) and damaged or debris-contaminated light-curing tips, among others, which can also affect the amount of light delivered to the restorations.1,18  In addition, it was observed that LCUs in dental offices are mostly poorly maintained and can deliver inadequate light output.1,18  This is a limitation of the present study, as light could always be delivered from a favorable position, and maintenance of the LCU was performed accordingly. Future studies should focus on evaluating the use of experimental materials with increased amounts of photoinitiator and comparing shortened light-curing times for a greater diversity of composites.

Based on the limitations of the present study, the following conclusions can be made:

  1. VPS is more greatly affected by the material tested than the light-curing mode. TEF showed higher VPS than the high-viscosity materials, TEC and TEE, in high-curing mode. Top shrinkage was more frequently observed than bottom/sides shrinkage.

  2. SBS is affected by the material used, TC, and curing modes. Turbo mode showed lower SBS values than high mode, except for TEF and TEE with TC.

  3. The CTS of the BFRCs studied was not affected by curing mode. However, TC reduced this property for all groups, except for TEE in high mode.

  4. TEE generally showed similar or improved values for the tested properties in a shortened curing time compared with the other BFRCs, except for CTS without TC.

This work was partially supported by the Fondo Nacional de Desarrollo Científico y Tecnológico, Chile (FONDECYT project 11170920).

Regulatory Statement

This study was conducted in accordance with all the provisions of the local human subjects oversight committee guidelines and policies of New York University Committee on Activities Involving Human Subjects.

Conflict of Interest

The authors of this article certify that they have no proprietary, financial, or other personal interest of any nature or kind in any product, service, and/or company that is presented in this article.

1.
Price
RB,
Ferracane
JL,
&
Shortall
AC
(
2015
)
Light-curing units: a review of what we need to know
Journal of Dental Research
94
(
9
)
1179
1186
.
2.
Ferracane
JL
(
2011
)
Resin composite—state of the art
Dental Materials
27
(
1
)
29
38
.
3.
Algamaiah
H,
Sampaio
CS,
Rigo
LC,
Janal
MN,
Giannini
M,
Bonfante
EA,
Coelho
PG,
Reis
AF,
&
Hirata
R
(
2017
)
Micro-computed tomography evaluation of volumetric shrinkage of bulk-fill composites in Class II cavities
Journal of Esthetic and Restorative Dentistry
29
(
2
)
118
127
.
4.
Atria
PJ,
Sampaio
CS,
Cáceres
E,
Fernández
J,
Reis
AF,
Coelho
PG,
&
Hirata
R
(
2018
)
Micro-computed tomography evaluation of volumetric polymerization shrinkage and degree of conversion of composites cured by various light power outputs
Dental Materials Journal
37
(
1
)
33
39
.
5.
Besegato
JF,
Jussiani
EI,
Andrello
AC,
Fernandes
RV,
Salomão
FM,
Vicentin
BLS,
Dezan-Garbellini
CC,
&
Hoeppner
MG
(
2019
)
Effect of light-curing protocols on the mechanical behavior of bulk-fill resin composites
Journal of the Mechanical Behavior of Biomedical Materials
90
381
387
.
6.
Bucuta
S
&
Ilie
N
(
2014
)
Light transmittance and micromechanical properties of bulk fill vs. conventional resin based composites
Clinical Oral Investigations
18
(
8
)
1991
2000
.
7.
Daugherty
MM,
Lien
W,
Mansell
MR,
Risk
DL,
Savett
DA,
&
Vandewalle
KS
(
2018
)
Effect of high-intensity curing lights on the polymerization of bulk-fill composites
Dental Materials
34
(
10
)
1531
1541
.
8.
Flury
S,
Peutzfeldt
A,
&
Lussi
A
(
2014
)
Influence of increment thickness on microhardness and dentin bond strength of bulk fill resin composites
Dental Materials
30
(
10
)
1104
1112
.
9.
Fronza
BM,
Rueggeberg
FA,
Braga
RR,
Mogilevych
B,
Soares
LE,
Martin
AA,
Ambrosano
G,
&
Giannini
M
(
2015
)
Monomer conversion, microhardness, internal marginal adaptation, and shrinkage stress of bulk-fill resin composites
Dental Materials
31
(
12
)
1542
1551
.
10.
Ilie
N
(
2017
)
Impact of light transmittance mode on polymerisation kinetics in bulk-fill resin-based composites
Journal of Dentistry
63
(
2017
)
51
59
.
11.
Ilie
N
(
2019
)
Sufficiency of curing in high-viscosity bulk-fill resin composites with enhanced opacity
Clinical Oral Investigations
23
(
2
)
747
755
.
12.
Ilie
N,
Bucuta
S,
&
Draenert
M
(
2013
)
Bulk-fill resinbased composites: an in vitro assessment of their mechanical performance
Operative Dentistry
38
(
6
)
618
625
.
13.
Li
X,
Pongprueksa
P,
Van Meerbeek
B,
&
De Munck
J
(
2015
)
Curing profile of bulk-fill resin-based composites
Journal of Dentistry
43
(
6
)
664
672
.
14.
Lima
RBW,
Troconis
CCM,
Moreno
MBP,
Murillo-Gómez
F,
&
De Goes
MF
(
2018
)
Depth of cure of bulk fill resin composites: a systematic review
Journal of Esthetic and Restorative Dentistry
30
(
6
)
492
501
.
15.
Sampaio
CS,
Chiu
KJ,
Farrokhmanesh
E,
Janal
M,
Puppin-Rontani
RM,
Giannini
M,
Bonfante
EA,
Coelho
PG,
&
Hirata
R
(
2017
)
Microcomputed tomography evaluation of polymerization shrinkage of class I flowable resin composite restorations
Operative Dentistry
42
(
1
)
e16
e23
.
16.
Van Ende
A,
De Munck
J,
Lise
DP,
&
Van Meerbeek
B
(
2017
)
Bulk-fill composites: a review of the current literature
Journal of Adhesive Dentistry
19
(
2
)
95
109
.
17.
Van Ende
A,
De Munck
J,
Van Landuyt,
Poitevin
A,
Peumans
M,
&
Van Meerbeek
B
(
2013
)
Bulk-filling of high C-factor posterior cavities: effect on adhesion to cavity-bottom dentin
Dental Materials
29
(
3
)
269
277
.
18.
Price
RBT
(
2017
)
Light curing in dentistry
Dental Clinics of North America
61
(
4
)
751
778
.
19.
Bernardo
M,
Luis
H,
Martin
MD,
Leroux
BG,
Rue
T,
Leitão
J,
&
DeRouen
TA
(
2007
)
Survival and reasons for failure of amalgam versus composite posterior restorations placed in a randomized clinical trial
Journal of the American Dental Association
138
(
6
)
775
783
.
20.
Opdam
NJ,
Bronkhorst
EM,
Roeters
JM,
&
Loomans
BA
(
2007
)
A retrospective clinical study on longevity of posterior composite and amalgam restorations
Dental Materials
23
(
1
)
2
8
.
21.
Moszner
N,
Fischer
UK,
Ganster
B,
Liska
R,
&
Rheinberger
V
(
2008
)
Benzoyl germanium derivatives as novel visible light photoinitiators for dental materials
Dental Materials
24
(
7
)
901
907
.
22.
Leprince
JG,
Hadis
M,
Shortall
AC,
Ferracane
JL,
Devaux
J,
Leloup
G,
&
Palin
WM
(
2011
)
Photoinitiator type and applicability of exposure reciprocity law in filled and unfilled photoactive resins
Dental Materials
27
(
2
)
157
164
.
23.
Kutuk
ZB,
Gurgan
S,
Hickel
R,
&
Illie
N
(
2017
)
Influence of extremely high irradiances on the micromechanical properties of a nano hybrid resin based composite
American Journal of Dentistry
30
(
1
)
9
15
.
24.
Sampaio
CS,
Barbosa
JM,
Cáceres
E,
Rigo
LC,
Coelho
PG,
Bonfante
EA,
&
Hirata
R
(
2017
)
Volumetric shrinkage and film thickness of cementation materials for veneers: an in vitro 3D microcomputed tomography analysis
Journal of Prosthetic Dentistry
117
(
6
)
784
791
.
25.
Caceres
EA,
Sampaio
CS,
Atria
PJ,
Moura
H,
Giannini
M,
Coelho
PG,
&
Hirata
R
(
2018
)
Void and gap evaluation using microcomputed tomography of different fiber post cementation techniques
Journal of Prosthetic Dentistry
119
(
1
)
103
107
.
26.
Sampaio
CS,
Atria
PJ,
Rueggeberg
FA,
Yamaguchi
S,
Giannini
M,
Coelho
PG,
Hirata
R,
&
Puppin-Rontani
RM
(
2017
)
Effect of blue and violet light on polymerization shrinkage vectors of a CQ/TPO-containing composite
Dental Materials
33
(
7
)
796
804
.
27.
Ilie
N,
Hilton
TJ,
Heintze
SD,
Hickel
R,
Watts
DC,
Silikas
N,
Stansburry
JW,
Cadenaro
M,
&
Ferracane
JL
(
2017
)
Academy of Dental Materials guidance—resin composites: part I—mechanical properties
Dental Materials
33
(
8
)
880
894
.
28.
Rinastiti
M,
Özcan
M,
Siswomihardjo
W,
&
Busscher
HJ
(
2011
)
Effects of surface conditioning on repair bond strengths of non-aged and aged microhybrid, nanohybrid, and nanofilled composite resins
Clinical Oral Investigations
15
(
5
)
625
633
.
29.
Braga
RR,
Ballester
RY,
&
Ferracane
JL
(
2005
)
Factors involved in the development of polymerization shrinkage stress in resin-composites: a systematic review
Dental Materials
21
(
10
)
962
970
.
30.
Burdick
JA,
Lovestead
TM,
&
Anseth
KS
(
2003
)
Kinetic chain lengths in highly cross-linked networks formed by the photoinitiated polymerization of divinyl monomers: a gel permeation chromatography investigation
Biomacromolecules
4
(
1
)
149
156
.
31.
Sampaio
CS,
Rodrigues
RV,
Souza-Junior
EJ,
Freitas
AZ,
Ambrosano
GM,
Pascon
FM,
&
Puppin-Rontani
RM
(
2016
)
Effect of restorative system and thermal cycling on the tooth-restoration interface–OCT evaluation
Operative Dentistry
41
(
2
)
162
170
.
32.
Yao
C,
Yang
H,
Yu
J,
Zhang
L,
Zhu
Y,
&
Huang
C
(
2018
)
High bond durability of universal adhesives on glass ceramics facilitated by silane pretreatment
Operative Dentistry
46
(
6
)
602
612
.
33.
Crim
GA,
Swartz
ML,
&
Phillips
RW
(
1985
)
Comparison of four thermocycling techniques
Journal of Prosthetic Dentistry
53
(
1
)
50
53
.
34.
Sai
K,
Shimamura
Y,
Takamizawa
T,
Tsujimoto
A,
Imai
A,
Endo
H,
Barkmeier
WW,
Latta
MA,
&
Miyazaki
M
(
2016
)
Influence of degradation conditions on dentin bonding durability of three universal adhesives
Journal of Dentistry
54
(
2016
)
56
61
.
35.
Pala
K,
Tekçe
N,
Tuncer
S,
Serim
ME,
&
Demirci
M
(
2016
)
Evaluation of the surface hardness, roughness, gloss and color of composites after different finishing/polishing treatments and thermocycling using a multi-technique approach
Dental Materials Journal
35
(
2
)
278
289
.

Author notes

*Camila S Sampaio, DDS, MS, PhD, assistant professor, Department of Biomaterials, College of Dentistry, Universidad de los Andes, Santiago, Chile

Paulina G Pizarro, DDS student, Department of Biomaterials, College of Dentistry, Universidad de los Andes, Santiago, Chile

Pablo J Atria, DDS, MS, assistant professor, Department of Biomaterials, College of Dentistry, Universidad de los Andes, Santiago, Chile

Ronaldo Hirata, DDS, MS, PhD, assistant professor, Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA

Marcelo Giannini, DDS, MS, PhD, associate professor, Department of Restorative Dentistry, Piracicaba Dental School, Piracicaba, SP, Brazil

Eduardo Mahn, DDS, MS, PhD, professor, Department of Restorative Dentistry, College of Dentistry, Universidad de los Andes, Santiago, Chile