Metabolomic analysis of easily accessible biofluids has provided numerous biomarkers in urine and blood for biodosimetric purposes. In this pilot study we assessed saliva for its utility in biodosimetry using a mouse model. Mice were exposed to 0.5, 3 and 8 Gy total-body gamma irradiation and saliva was collected on day 1 and 7 postirradiation. Global metabolomic profiling was conducted through liquid chromatography mass spectrometry and metabolites were positively identified using tandem mass spectrometry. Multivariate data analysis revealed distinct metabolic profiles for all groups at day 1, whereas at day 7 the two lower dose profiles appeared to have minimal differences. Metabolites that were identified include amino acids and fatty acids, and intermediates of the nicotinate and nicotinamide metabolism. The specificity and sensitivity of the radiation signature, as expected, was higher for the 8 Gy dose at both time points, as determined through generation of receiver operating characteristic curves. To the best of our knowledge, this is the first metabolomics study in saliva of irradiated mice to demonstrate the utility of this biofluid as a potential matrix for identification of radiation and dose-specific biomarkers.
Skip Nav Destination
Close
Article navigation
1 July 2016
Research Article|
June 22 2016
Assessment of Saliva as a Potential Biofluid for Biodosimetry: A Pilot Metabolomics Study in Mice
Evagelia C. Laiakis
;
Evagelia C. Laiakis
1
aDepartment of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington, DC
1Address for correspondence: Georgetown University, 3970 Reservoir Road, NW, New Research Building, Room E504, Washington, DC 20057; e-mail: ecl28@georgetown.edu.
Search for other works by this author on:
Steven J. Strawn
;
Steven J. Strawn
bProMetic BioTherapeutics, Inc., Rockville, Maryland
Search for other works by this author on:
David J. Brenner
;
David J. Brenner
cColumbia University, New York, New York
Search for other works by this author on:
Albert J. Fornace, Jr.
Albert J. Fornace, Jr.
aDepartment of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington, DC
dLombardi Comprehensive Cancer Center, Georgetown University, Washington, DC
Search for other works by this author on:
Radiat Res (2016) 186 (1): 92–97.
Article history
Received:
February 24 2016
Accepted:
April 19 2016
Citation
Evagelia C. Laiakis, Steven J. Strawn, David J. Brenner, Albert J. Fornace; Assessment of Saliva as a Potential Biofluid for Biodosimetry: A Pilot Metabolomics Study in Mice. Radiat Res 1 July 2016; 186 (1): 92–97. doi: https://doi.org/10.1667/RR14433.1
Download citation file:
Close
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Sign in via your Institution
Sign in via your InstitutionCiting articles via
Commonalities Between COVID-19 and Radiation Injury
Carmen I. Rios, David R. Cassatt, Brynn A. Hollingsworth, Merriline M. Satyamitra, Yeabsera S. Tadesse, Lanyn P. Taliaferro, Thomas A. Winters, Andrea L. DiCarlo
Low-Dose Radiation Therapy (LDRT) for COVID-19: Benefits or Risks?
Pataje G. Prasanna, Gayle E. Woloschak, Andrea L. DiCarlo, Jeffrey C. Buchsbaum, Dörthe Schaue, Arnab Chakravarti, Francis A. Cucinotta, Silvia C. Formenti, Chandan Guha, Dale J. Hu, Mohammad K. Khan, David G. Kirsch, Sunil Krishnan, Wolfgang W. Leitner, Brian Marples, William McBride, Minesh P. Mehta, Shahin Rafii, Elad Sharon, Julie M. Sullivan, Ralph R. Weichselbaum, Mansoor M. Ahmed, Bhadrasain Vikram, C. Norman Coleman, Kathryn D. Held
Germicidal Efficacy and Mammalian Skin Safety of 222-nm UV Light
Manuela Buonanno, Brian Ponnaiya, David Welch, Milda Stanislauskas, Gerhard Randers-Pehrson, Lubomir Smilenov, Franklin D. Lowy, David M. Owens, David J. Brenner