In response to the limitations of computed tomography (CT) and cone-beam CT (CBCT) in irradiation guidance, especially for soft-tissue targets without the use of contrast agents, our group developed a solution that implemented bioluminescence tomography (BLT) as the image-guidance modality for preclinical radiation research. However, adding such a system to existing small animal irradiators is no small task. A potential solution is to utilize an off-line BLT system in close proximity to the irradiator, with stable and effective animal transport between the two systems. In this study, we investigated the localization accuracy of an off-line BLT system when used for the small animal radiation research platform (SARRP) and compared the results with those of an on-line system. The CBCT was equipped on both the off-line BLT system and the SARRP, with a distance of 5 m between them. To evaluate the setup error during animal transport between the two systems, the mice underwent CBCT imaging on the SARRP and were then transported to the off-line system for a second CBCT imaging session. The normalized intensity difference of the two images and the corresponding histogram and correlation were computed to evaluate if the transport process perturbed animal positioning. Strong correlation (correlation coefficients >0.95) between the SARRP and the off-line mouse CBCT was observed. The offset of the implanted light source center can be maintained within 0.2 mm during transport. To compare the target localization accuracy using the on-line SARRP BLT and the off-line system, a self-illuminated bioluminescent source was implanted in the abdomen of anesthetized mice. In addition to the application for dose calculation, CBCT imaging was also employed to generate the mesh grid of the imaged mouse for BLT reconstruction. Two scenarios were devised and compared, which involved localization of the luminescence source based on either: 1. on-line SARRP bioluminescence image and CBCT; or 2. off-line bioluminescence image and SARRP CBCT. The first scenario is assumed to have the least setup error, because no animal transport was involved. The second scenario examines if an off-line BLT system, with the mesh generated from the SARRP CBCT, can be used to guide SARRP irradiation when there is minimal target contrast in CBCT. Stability during animal transport between the two systems was maintained. The center of mass (CoM) of the light source reconstructed by the off-line BLT had an offset of 1.0 ± 0.4 mm from the true CoM derived from the SARRP CBCT. These results are comparable to the offset of 1.0 ± 0.2 mm using on-line BLT. With CBCT information provided by the SARRP and effective animal immobilization during transport, these findings support the utilization of an off-line BLT-guided system, in close proximity to the SARRP, for accurate soft-tissue target localization. In addition, a dedicated standalone BLT system for our partner site at the University of Pennsylvania was introduced in this study.
Skip Nav Destination
Article navigation
1 December 2016
Research Article|
November 21 2016
Evaluation of On- and Off-Line Bioluminescence Tomography System for Focal Irradiation Guidance
Bin Zhang
;
Bin Zhang
aDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland
Search for other works by this author on:
John W. Wong
;
John W. Wong
aDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland
Search for other works by this author on:
Iulian I. Iordachita
;
Iulian I. Iordachita
bLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland
Search for other works by this author on:
Juvenal Reyes
;
Juvenal Reyes
aDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland
Search for other works by this author on:
Katriana Nugent
;
Katriana Nugent
aDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland
Search for other works by this author on:
Phuoc T. Tran
;
Phuoc T. Tran
aDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland
cDepartments of Oncology and Urology, Johns Hopkins University, Baltimore, Maryland
Search for other works by this author on:
Stephen W. Tuttle
;
Stephen W. Tuttle
dDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
Search for other works by this author on:
Constantinos Koumenis
;
Constantinos Koumenis
dDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania
Search for other works by this author on:
Ken Kang-Hsin Wang
Ken Kang-Hsin Wang
1
aDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland
1Address for correspondence: Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, 401 N. Broadway, Suite 1440, Baltimore, MD 21231; e-mail: kwang27@jhmi.edu.
Search for other works by this author on:
Radiat Res (2016) 186 (6): 592–601.
Citation
Bin Zhang, John W. Wong, Iulian I. Iordachita, Juvenal Reyes, Katriana Nugent, Phuoc T. Tran, Stephen W. Tuttle, Constantinos Koumenis, Ken Kang-Hsin Wang; Evaluation of On- and Off-Line Bioluminescence Tomography System for Focal Irradiation Guidance. Radiat Res 1 December 2016; 186 (6): 592–601. doi: https://doi.org/10.1667/RR14423.1
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Sign in via your Institution
Sign in via your InstitutionCiting articles via
Commonalities Between COVID-19 and Radiation Injury
Carmen I. Rios, David R. Cassatt, Brynn A. Hollingsworth, Merriline M. Satyamitra, Yeabsera S. Tadesse, Lanyn P. Taliaferro, Thomas A. Winters, Andrea L. DiCarlo
Monte Carlo Simulation of SARS-CoV-2 Radiation-Induced Inactivation for Vaccine Development
Ziad Francis, Sebastien Incerti, Sara A. Zein, Nathanael Lampe, Carlos A. Guzman, Marco Durante
Low-Dose Radiation Therapy (LDRT) for COVID-19: Benefits or Risks?
Pataje G. Prasanna, Gayle E. Woloschak, Andrea L. DiCarlo, Jeffrey C. Buchsbaum, Dörthe Schaue, Arnab Chakravarti, Francis A. Cucinotta, Silvia C. Formenti, Chandan Guha, Dale J. Hu, Mohammad K. Khan, David G. Kirsch, Sunil Krishnan, Wolfgang W. Leitner, Brian Marples, William McBride, Minesh P. Mehta, Shahin Rafii, Elad Sharon, Julie M. Sullivan, Ralph R. Weichselbaum, Mansoor M. Ahmed, Bhadrasain Vikram, C. Norman Coleman, Kathryn D. Held
Germicidal Efficacy and Mammalian Skin Safety of 222-nm UV Light
Manuela Buonanno, Brian Ponnaiya, David Welch, Milda Stanislauskas, Gerhard Randers-Pehrson, Lubomir Smilenov, Franklin D. Lowy, David M. Owens, David J. Brenner
Photon GRID Radiation Therapy: A Physics and Dosimetry White Paper from the Radiosurgery Society (RSS) GRID/LATTICE, Microbeam and FLASH Radiotherapy Working Group
Hualin Zhang, Xiaodong Wu, Xin Zhang, Sha X. Chang, Ali Megooni, Eric D. Donnelly, Mansoor M. Ahmed, Robert J. Griffin, James S. Welsh, Charles B. Simone, II, Nina A. Mayr