Assessment of health effects from low-dose radiation exposures in patients undergoing diagnostic imaging is an active area of research. High-quality dosimetry information pertaining to these medical exposures is generally not readily available to clinicians or epidemiologists studying radiation-related health risks. The purpose of this study was to provide methods for organ dose estimation in pediatric patients undergoing four common diagnostic fluoroscopy procedures: the upper gastrointestinal (UGI) series, the lower gastrointestinal (LGI) series, the voiding cystourethrogram (VCUG) and the modified barium swallow (MBS). Abstracted X-ray film data and physician interviews were combined to generate procedure outlines detailing X-ray beam projections, imaged anatomy, length of X-ray exposure, and presence and amount of contrast within imaged anatomy. Monte Carlo radiation transport simulations were completed for each of the four diagnostic fluoroscopy procedures across the 162-member (87 males and 75 females) University of Florida/National Cancer Institute pediatric phantom library, which covers variations in both subject height and weight. Absorbed doses to 28 organs, including the active marrow and bone endosteum, were assigned for all 162 phantoms by procedure. Additionally, we provide dose coefficients (DCs) in a series of supplementary tables. The DCs give organ doses normalized to procedure-specific dose metrics, including: air kerma-area product (µGy/mGy · cm2), air kerma at the reference point (µGy/µGy), number of spot films (SF) (µGy/number of SFs) and total fluoroscopy time (µGy/s). Organs accumulating the highest absorbed doses per procedure were as follows: kidneys between 0.9–25.4 mGy, 1.1–16.6 mGy and 1.1–9.7 mGy for the UGI, LGI and VCUG procedures, respectively, and salivary glands between 0.2–3.7 mGy for the MBS procedure. Average values of detriment-weighted dose, a phantom-specific surrogate for the effective dose based on ICRP Publication 103 tissue-weighting factors, were 0.98 mSv, 1.16 mSv, 0.83 mSv and 0.15 mSv for the UGI, LGI, VCUG and MBS procedures, respectively. Scalable database of organ dose coefficients by patient sex, height and weight, and by procedure exposure time, reference point air kerma, kerma-area product or number of spot films, allows clinicians and researchers to compute organ absorbed doses based on their institution-specific and patient-specific dose metrics. In addition to informing on patient dosimetry, this work has the potential to facilitate exposure assessments in epidemiological studies designed to investigate radiation-related risks.
Skip Nav Destination
Close
Article navigation
1 December 2019
Research Article|
October 15 2019
A Scalable Database of Organ Doses for Common Diagnostic Fluoroscopy Procedures of Children: Procedures of Historical Practice for Use in Radiation Epidemiology Studies
Emily L. Marshall
;
Emily L. Marshall
1
aJ. Crayton Pruitt Family Department of Biomedical Engineering
Search for other works by this author on:
Dhanashree Rajderkar
;
Dhanashree Rajderkar
bDepartment of Radiology
Search for other works by this author on:
Justin L. Brown
;
Justin L. Brown
cDepartment of Medical Physics Program, College of Medicine, University of Florida, Gainesville, Florida
Search for other works by this author on:
Elliott J. Stepusin
;
Elliott J. Stepusin
2
aJ. Crayton Pruitt Family Department of Biomedical Engineering
Search for other works by this author on:
David Borrego
;
David Borrego
dDivision of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland
Search for other works by this author on:
James Duncan
;
James Duncan
eMallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri
Search for other works by this author on:
Christina L. Sammet
;
Christina L. Sammet
fAnn & Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois
Search for other works by this author on:
Julie R. Munneke
;
Julie R. Munneke
fAnn & Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois
Search for other works by this author on:
Marilyn L. Kwan
;
Marilyn L. Kwan
fAnn & Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois
Search for other works by this author on:
Diana L. Miglioretti
;
Diana L. Miglioretti
gDivision of Research, Kaiser Permanente Northern California, Oakland, California
iDepartment of Kaiser Permanente Washington Health Research Institute, Seattle, Washington
Search for other works by this author on:
Rebecca Smith-Bindman
;
Rebecca Smith-Bindman
jDepartment of Radiology and Biomedical Imaging, Epidemiology, and Biostatistics, and the Phillip R. Lee Institute for Health Policy Studies, The University of California - San Francisco School of Medicine, San Francisco, California
Search for other works by this author on:
Wesley E. Bolch
Wesley E. Bolch
3
aJ. Crayton Pruitt Family Department of Biomedical Engineering
3Address for correspondence: Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611-6550; email: wbolch@ufl.edu.
Search for other works by this author on:
Radiat Res (2019) 192 (6): 649–661.
Article history
Received:
May 31 2019
Accepted:
September 17 2019
Citation
Emily L. Marshall, Dhanashree Rajderkar, Justin L. Brown, Elliott J. Stepusin, David Borrego, James Duncan, Christina L. Sammet, Julie R. Munneke, Marilyn L. Kwan, Diana L. Miglioretti, Rebecca Smith-Bindman, Wesley E. Bolch; A Scalable Database of Organ Doses for Common Diagnostic Fluoroscopy Procedures of Children: Procedures of Historical Practice for Use in Radiation Epidemiology Studies. Radiat Res 1 December 2019; 192 (6): 649–661. doi: https://doi.org/10.1667/RR15445.1
Download citation file:
Close
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Sign in via your Institution
Sign in via your Institution
2
Views
0
Citations
Citing articles via
Commonalities Between COVID-19 and Radiation Injury
Carmen I. Rios, David R. Cassatt, Brynn A. Hollingsworth, Merriline M. Satyamitra, Yeabsera S. Tadesse, Lanyn P. Taliaferro, Thomas A. Winters, Andrea L. DiCarlo
Low-Dose Radiation Therapy (LDRT) for COVID-19: Benefits or Risks?
Pataje G. Prasanna, Gayle E. Woloschak, Andrea L. DiCarlo, Jeffrey C. Buchsbaum, Dörthe Schaue, Arnab Chakravarti, Francis A. Cucinotta, Silvia C. Formenti, Chandan Guha, Dale J. Hu, Mohammad K. Khan, David G. Kirsch, Sunil Krishnan, Wolfgang W. Leitner, Brian Marples, William McBride, Minesh P. Mehta, Shahin Rafii, Elad Sharon, Julie M. Sullivan, Ralph R. Weichselbaum, Mansoor M. Ahmed, Bhadrasain Vikram, C. Norman Coleman, Kathryn D. Held
Germicidal Efficacy and Mammalian Skin Safety of 222-nm UV Light
Manuela Buonanno, Brian Ponnaiya, David Welch, Milda Stanislauskas, Gerhard Randers-Pehrson, Lubomir Smilenov, Franklin D. Lowy, David M. Owens, David J. Brenner