Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
NARROW
Format
Journal
Article Type
Date
Availability
1-1 of 1
Sahaja Acharya
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Journal Articles
Ru Xin Wong, MBBS, Jacqueline Faught, PhD, Melissa Gargone, MHS, William Myers, PhD, Matthew Krasin, MD ...
International Journal of Particle Therapy (2021) 7 (4): 65–73.
Published: 09 March 2021
Abstract
Purpose Whole lung irradiation (WLI) is indicated for certain pediatric patients with lung metastases. This study investigated whether WLI delivered as intensity-modulated proton therapy (IMPT) could significantly spare the heart and breasts when compared with conventional WLI delivered with anteroposterior/posteroanterior photon fields and with intensity-modulated photon therapy (IMRT) WLI. Materials and Methods Conventional, IMRT, and IMPT plans were generated for 5 patients (aged 5-22 years). The prescription dose was 16.5 GyRBE in 1.5-GyRBE fractions. Conventional plans used 6-MV photons prescribed to the midline and a field-in-field technique to cover the planning target volume (the internal target volume [ITV] + 1 cm). IMRT plans used 6-MV photons with a 7-beam arrangement with dose prescribed to the planning target volume. IMPT plans used scenario-based optimization with 5% range uncertainty and 5-mm positional uncertainty to cover the ITV robustly. Monte Carlo dose calculation was used for all IMPT plans. Doses were compared with paired Student t test. Results The ITV Dmean was similar for the IMPT, conventional, and IMRT plans, but the IMPT plans had a lower Dmin and a higher Dmax at tissue interfaces than conventional plans (Dmean ratio: 0.96, P > .05; Dmin ratio: 0.9, P < .001; Dmax ratio: 1.1, P = .014). Dmeans for breast and heart substructures were lower with IMPT plans than with conventional/IMRT plans (heart ratios, 0.63:0.73; left ventricle ratios, 0.61:0.72; right ventricle ratios, 0.45:0.57; left atrium ratios, 0.79:0.85; right atrium ratios, 0.81:0.86; left breast ratios, 0.40:0.51; right breast ratio, 0.46:0.52; all P < .05). Conclusions IMPT resulted in comparable ITV coverage and lower mean doses to the heart and breasts when compared with other techniques. Whole lung irradiation delivered as IMPT warrants prospective evaluation in pediatric patients.
Includes: Supplementary data